Laserfiche WebLink
L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 03/05/2025 <br /> LEGEND <br /> SEE SHEET 40-009-M1 <br /> GENERAL NOTES <br /> 1. FOR GENERAL NOTES, SEE SHEET 40-009-M1. <br /> ADUAL-CHANNEL PH TRANSMITTER (E) BUILDING 2. PIPING, VALVES, AND FLANGE COUPLING ADAPTER (FCA) <br /> MATERIAL OF CONSTRUCTION SHALL BE STAINLESS <br /> FLOW TRANSMITTER STEEL. <br /> 0 <br /> I <br /> 0 REFERENCE DRAWINGS <br /> DINI <br /> TEMPORARY PH PHOBE 10" KNIFE �FOR MAG FLOW METER, PH METER, AND SUMP PUMP <br /> 5 GATE VALVE PRODUCT INFORMATION SEE DRAWING 40-009-M311. <br /> OM110 M503 (TYP) <br /> 10" FLOW METER 27"x10" FRP I A <br /> T1OM5(3 <br /> 6 �HAZARDOUS�DRAWING <br /> CLASSIFICATION: UNCLASSIFIEDOM OM110 M503 REDUCER (TYP) <br /> 1 10"-SAN-SS AREA. SEE 0-009-A3 <br /> 'j <br /> A -- ----- 1 -------- T <br /> I <br /> 1Id — , — — X OM110 M502 CONSTRUCTION NOTES <br /> ------ 10" FCA L-------------- -- __-�/ � COVER (E) OPEN CHANNEL BYPASS WITH A STAINLESS <br /> - 4'-2" MIN STEEL PANEL. CONTRACTOR TO FIELD VERIFY <br /> LY--6" MIN DIMENSIONS. ANCHOR STAINLESS STEEL PANELS PER <br /> 3 1 MANUFACTURER'S RECOMMENDATIONS. <br /> (E) 27"-SAN I (E) 27"-SAN <br /> I <br /> I INSTALL 4" PVC VENT PIPE. SEAL PIPE PENETRATION <br /> I THROUGH STAINLESS STEEL PANEL. EXTEND VENT PIPE <br /> THROUGH ROOF AND SEAL PENETRATION. OUTDOOR <br /> VENT SHALL BE U-SHAPE EQUIPPED WITH BIRD <br /> SCREEN. <br /> 2 n 4 n 2 <br /> 1 PROVIDE SUMP PUMP AND ROUTE DISCHARGE PIPING TO <br /> VENT TO ROOF (E) WEIR FRP COVER PLATE VENT TO ROOF OPEN CHANNEL BYPASS. SEAL PIPE PENETRATION <br /> THROUGH THE FRP PANEL. <br /> ® PROVIDE TEMPORARY ACCESS TO (E) WEIR TO ALLOW <br /> FOR FLOW RATE CALCULATIONS IN THE FIELD DURING <br /> CONSTRUCTION. ACCESS TO THE (E) WEIR SHALL BE <br /> SEALED PERMANENTLY AFTER SEWER METER <br /> MODIFICATIONS ARE COMPLETED. <br /> PIPING PLAN <br /> SCALE: 1/2" = 1'-0" <br /> 90% REVIEW Kennedy/Jenks Consultants <br /> 0/1" 1 �1 "/1 32001 32nd Avenue South,Suite 101 <br /> L -I L Federal Way,WA 98007 <br /> Ph.253-835-6400 <br /> Fax 253.952.3435 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATEERIC ACCEPTABILITY B. HOPPER D2.11.25 SUBTRLE CURRENr REVISION SYMBOL DATE <br /> ��� A�o THIS DESIGN AND/OR PIPING FLOOR PLAN C238185 A 02.11.25 <br /> ORIG 100%FINAL DESIGN—ISSUED FOR CONSTRUCTION C238185 KJ JEA 09.25.23 �,p SPECIFICATION IS APPROVED B.G. DOCKlOR 02.11.25 SHEET <br /> TffLE <br /> A SEWER METER BYPASS(PHASE 1) C238185 KJ JEA 02.11.25BOE//VG® 2 N <br /> o x APPROVED BY DEPT. DATE J.ANDERSON 02.11.25 0 M 110 <br /> CHECKED <br /> M.ROVED C238185 <br /> D2.,,.25 <br /> APPROVED BUILDING 40-09 JOB NO. COMP N0. <br /> 55 3 <br /> °VIAL APPROVED MECHANICAL MASTER COL. X-X/X-X EVERETT. WA,D-N0. 40-009-OM110 <br />