My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2025 BLDG 40-25 Plans 2025-12-01 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-25
>
Plans
>
3003 W CASINO RD 2025 BLDG 40-25 Plans 2025-12-01 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2025 11:34:26 AM
Creation date
12/1/2025 11:34:21 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-25
Permit
K2507-005
Year
2025
Notes
Bldg 40-25 #64/#65 Elevator Pit TI-remove extg sprinklers
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
.� GGG G����� 2 2 .5 <br /> O J <br /> ry'+�/.��0p�� SEE DRAW NG FT-7 <br /> �•_g DIN 1 X 0-4 W/ 1" BALL VALVE & PLUG <br /> 11 2 ±UM <br /> '•UP TO 8"TOWER <br /> 7 eISFIR ON 1ST FLOOR - <br /> + zo EL 96'-8° o <br /> \, 1v 1 1\,I 1\, 1\, I\, I\, N^4`zO 2, 2, 2, 2,1 2' 5 12-1 2'I 2' 1\' I\,I 1\' III t\' <br /> - 6-0 12-0 12-0 @-0I 12-0 5-6 6-6 12-0 12-0 12-0 12-0 12-0 12-0 -0 10-0 12-0 12-0 12-0 12-0 12 0 12-0 <br /> ALL LINES TO BE CL.I 1'-0" B.O.D. (U.N.O.) �� SI I <br /> CL. 2'-4" B.O. . <br /> I I I 1 10•41 1 1 1 1 1 1 1 <br /> N <br /> 2- l\' 1\' 1 1\' 1\ 1\' 1\' 1\' 1\' l\'E) el l\' l\' 1\' 1\' 1\' \' 1\' <br /> - II 3 I 12-0 12-0 12-0 l 6 N -6 12-0 112-0 12-0 12-0 12-0 12-0 12-0 12-0 - 2 12-0 B 12-0 -6 10-6 I 12-0 12-0 <br /> 5 5-2 e <br /> Ty <br /> It EL 98'-0" (TYP) <br /> PJ REMOVE ALL ^5 'PLUG___ <br /> _ / 1 <br /> SIDEWALLS <br /> _ CL.1'-0" B.O.D. HEAD GAUR <br /> _ RE MO L PIPE, <br /> D <br /> PIP H <br /> i <br /> II II AREA WORK <br /> PARTIAL UNDERFLOOR FIRE PROTECTION PLAN <br /> SCALE: 1/8"=1'-O" <br /> SCOPE OF WORK: <br /> -THIS CONTRACT IS TO REMOVE ALL SPRINKLER HEADS AND PIPING FROM THE PIT O <br /> THE EXISTING HOISTWAY OF FREIGHT ELEVATOR #64, IN ACORDANCE WITH NFPA-13, <br /> 1 2 3 4 5 6 7 8 9 1 0 11 <br /> 2019 EDITION, SECTION 9.3.6.3. THE HOISTWAY SHALL BE PROTECTED BY EITHER SMOKE 0.9 11' <br /> DETECTORS OR OTHER AUTOMATIC FIRE DETECTION INSTALLED IN ACCORDANCE WITH NFPA-72. 1 BILDG 40t24 <br /> i 25 I II K <br /> FITTER NOTES: <br /> 1 REMOVE ALL COMPONENTS OF THE EXISTING SPRINKLER SYSTEM. <br /> 2) PLUG THE EXISTING 2" OUTLET OUTSIDE OF ELEVATOR HOISTWAY. 1 j <br /> 3) ALL ELECTRICAL COMPONENTS AND IT'S WIRING SHALL BE PROVIDE BY OTHERS. r� <br /> I I o <br /> BLDG 40+25 j <br /> -— — 1 L.7 0 <br /> M M <br /> AREA N <br /> OF <br /> WORK BLDG 40-26 <br /> KEY PLAN N <br /> SCALE: NONE K2507-005 <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 07/18/2025 <br /> Submittal Drawing <br /> ABBREVIATIONS SPRINKLER LEGEND WATER SUPPLY INFORMATION REVISIONS STAMP PROJECT: <br /> W AFF-CENTERLINEABOVE FINISH FLOOR SYMBOL MAKE MODEL STYLE S.I.N. TEMP. N.P.T. K-FCTR. CANOPY FINISH TOTAL STATIC: NO. DATE BY DESCRIPTION KING- Boeing 40-25 <br /> BFC-CENTERLINE BELOW FINISH CEILING ��� ����� <br /> BOB-CENTERLINE BELOW BOTTOM OF BEAM RESIDUAL: n n�TAT�O�/ <br /> BOC-CENTERLINE BELOW BOTTOM OF CHANNEL Q e[Pwvr�a*ron s'wrrwuw mi�Iq{ l 3003 W. A.Casino8 Rd. <br /> FLOWING: FIRE PROTECTION <br /> BOO-CENTERLINE BELOW BOTTOM OF DECK Q DWlyrt -C Everett,WA.98203 <br /> BOP-CENTERLINE BELOW B070M OF JOIST %*VA01C LwN3 <br /> BOP-CENTERLINEBELOW BOTTOM OF PURLIN DATE: Q �yygAMAae.x sPTNMeeT coTToanr � VIKING AUTOMATIC SPRINKLER COMPANY <br /> N BTJ-CENTERLINE BELOWTOPOFJOIST VMe1N8373NT 3434 FIRST AVENUE SOUTH <br /> S LOCATION: Q <br /> GOE GRTONJob MEDFOND SEATTLE,WA.98134 LONGVIeW <br /> TOE-GROOVE ONE END $tClf�rn 711$1L$ MEDFORD MERIDEAN <br /> PROVIDED BY: Q PHONE:12061622-4656 FAX:(206)622-9319 Fire Protection Demo Work <br /> TOE-THREAD ONE ENO SEATTLE POCATELLO <br /> GG-GROOVE x GROOVE FIRE PUMP INFORMATION Q """""""""""""" CCBO#:VIKINAS373NT <br /> T-G-THREADx GROOVE <br /> T-T-THREAD.THREAD PUMP TYPE: Q DALE DRAWN: <br /> DRAWN BY: GC SHEET NUMBER <br /> N.I.C.-NOT IN CONTRACT <br /> THIS DRAWING IS THE PROPERTY OF VIKING AUTOMATIC SPRINKLER COMPANY. <br /> POO-POINT OF CONNECTION TOTAL SPRINKLER THIS SHEET: RATED PRESSURE: APPROVING AUTHORITIES IT IS SUBMITTED IN CONFIDENCE AND IS NOT TO BE DISCLOSED OR UTILIZED F P 1 <br /> E G.O.L.:GROOVEOLET(GROOVED WELDED OUTLET) WITHOUT THE WRIT TEN PERMISSION OF VIKING AUTOMATIC SPRINKLER COMPANY. SCPLE: PRaECTNUMBER: <br /> P.O.L.PIPEO-LET(THREADED WELDED OUTLET) TOTALSPRINKLERSTHIS PROJECT: RATED GPM: BoeingFire and the Cityof Everett Noted wo- <br />
The URL can be used to link to this page
Your browser does not support the video tag.