My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY 2025 ZAP ENERGY Plans 2025-12-02
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
Plans
>
2300 MERRILL CREEK PKY 2025 ZAP ENERGY Plans 2025-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 8:24:33 AM
Creation date
12/2/2025 8:24:16 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Permit
K2501-008
Year
2025
Notes
ZAP ENERGY CONNEX SUPPRESSION SYSTEMS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SION <br /> S INC. <br /> CLEAN AGENT AREA VOLUME CALCULATIONS SUPIAL H—RDSYSTEOTECTO <br /> SPECIAL HAZARDS FIRE PROTECTION <br /> FI E 20TH STREET EAST,SUITE B <br /> FIFE,WA 98420-1 793 <br /> MINIMUM ADJUSTED ESTIMATED n(253)9263300 FM(253)92"3N <br /> 001 002 004 020 021 NON PERMEABLE AGENT ELEVATION MINIMUM AGENT FREE VENT <br /> Al AI AI 2 p I p ROOM DESCRIPTION AREA DEPTH VOLUME VOLUME CONCENTRATION REQUIRES AGENT CORRECTION AGENT SUPPLIED CYLINDER AREA <br /> (SQUARE FEET) (FEET) (CUBIC FEET) (CUBIC FEET) (%BY VOLUME) (POUNDS) FACTOR REQUIRED (POUNDS) SUPPLIED (SQUARE <br /> 0 01 NICET STAMPS <br /> P (POUNDS) FEET) <br /> SHIPPING CONTAINER 160.00 7'-6" 1155 45 46.90 54.0 54.0 54.3 80 L 0.2 <br /> m N NETWORKJINTERFACE BANK A+MTS <br /> � to uva° <br /> y til 7 �e <br /> fA rn�n,nn" <br /> °C °� RS-232 <br /> rB, re,5ALARM 3 <br /> SUPERVISORY RELAY 1 Tea VOLUME CALCULATION NOTES: --� <br /> RELAY 2 T6e <br /> DISCHARGE 1. FORMULA FOR CALCULATIONS: " � ° <br /> TROUBLE RELAY 3 Te9 KI D D E AR I ES-S LX 1.1. AREA x DEPTH=VOLUME <br /> RELAY4 TB,9 1.2. MINIMUM AMOUNT OF AGENT REQUIRED X ELEVATION CORRECTION= 90°ELBOW 1/2"NPT <br /> WIRING BY OTHERS MANUFACTURER LOGO'S <br /> NTR L PAN E L ADJUSTED MINIMUM AGENT REQUIRED <br /> 2. NON-PERMEABLE VOLUME OF 45CF APPLIED. 1/2"NPT DISCHARGE PIPE TO <br /> 3. FOR ADDITIONAL INFORMATION SEE THE CLEAN AGENT FLOW CALCULATIONS REDUCE 3/4"X 1/2"NPT DISCHARGE NOZZLE fKidde <br /> BATTERY Tea INCLUDED IN THE SUBMITTAL PACKAGE. o Fire Systems <br /> Te NAC 2 30cd 4. AGENT DESIGN CONCENTRATION IS FROM NFPA 2001 AND MANUFACTURE - <br /> RECOMMENDATIONS. FLEX HOSE PN: ��UNION 1/2"NPT <br /> Tes NAC 1 <br /> 0.130A 38-400330-410 TEE 3/4"NPT <br /> ISOMETRIC PIPING NOTES: - <br /> TB,2 TBll T. T. TBs ADAPTER 3/4",BSP TO NPT <br /> N � N 5. PIPE LENGTH'S DO NOT REPRESENT CUT LENGTH'S. CYLINDER VALVE AND - <br /> 120VAC INPUT POWER nc aoweR rB,3 w m °° m m 6. ALL LENGTH'S SHALL BE FIELD VERIFIED. DISCHARGE HOSE SEE <br /> WIRING BY OTHERS x 7. ALL PIPING 1/2"TO 1 1/2"SHALL BE THREADED.MINIMUM AND MAXIMUM ACTUATION DETAIL <br /> w w O o PRESSURE RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH <br /> SPECIAL HAZARD FIRE SUPPRESSION SYSTEMS. O FIRE PROTECTION ENGINEERS STAMP <br /> EOL 8. ALL PIPING 2"TO 6"SHALL BE GROOVED.MINIMUM AND MAXIMUM PRESSURE <br /> 30cd <br /> EOL RATINGS SHALL MEET FSSA PIPE DESIGN GUIDE FOR USE WITH SPECIAL <br /> 0.158A HAZARD FIRE SUPPRESSION SYSTEMS. <br /> 9. ANY DEVIATIONS IN PIPE LENGTH OR SIZE SHALL BE APPROVED BY <br /> SUPPRESSION SYSTEMS INC.PRIOR TO BEGINNING INSTALLATION. <br /> CLEAN AGENT NOTES <br /> M ILR $QL 1/2"X 6'-4" n SUUBPUANCE MIITALS DATE <br /> LO• R 1/2"XU-3" 100%SUBMITTAL 12/06/24 <br /> CLEAN AGENT 38-407500-055 <br /> CYLINDER <br /> 1/2"X V-0" PN:38-428031-100 REV DESCRIPTION DATE <br /> OWNER 12/17/24 <br /> COMMENTS <br /> 1/2-X 1'-6„ <br /> 2 <br /> REDUCE 3/4"X 1/2"NPT Q3 <br /> 10.5" <br /> SINGLE LINE WIRING CLEAN AGENT ISOMETRIC CYLINDER ARRANGEMENT <br /> z <br /> 0 <br /> 30ctl U <br /> P w <br /> ztti� �021 �020 0 0 o O Q o <br /> 0 o 0 o N <br /> wmm M¢ P¢ ^ Y 07 <br /> 00 BUILDING FIRE ALARM CONTROL PANEL LL Q Z <br /> ����� LOCATION OF CYLINDER AND PANEL 0 W O- O <br /> 0 Y � <br /> 10 LOCATION OF THE CONEX MTS/A+ w CD <br /> LLJ <br /> FRONT PLAN TOP PLAN BACK PLAN x <br /> F w z _jQ <br /> Z 0 F � <br /> w U <br /> 0- ww <br /> N - o w <br /> o > <br /> x Nw <br /> 2. z <br /> ZN O _ <br /> yo ¢ Q <br /> a N /mil <br /> Eo o �V <br /> E z x <br /> IL y F <br /> xa � <br /> 2 w 00 <br /> m <br /> Wa 0 <br /> y a <br /> O <br /> T— <br /> fl DESIGNED BY:NMB SCALE: <br /> - DRAWN BY: NMB NOT TO <br /> = SCALE <br /> -- '„ UNLESS <br /> CHECKED BY:ZST NOTED <br /> JOB NUMBER:2473 OTHERWISE <br /> SHEET TITLE: <br /> ' FIRE PROTECTION DRAWINGS <br /> j' CONEX MTS/A+FLOOR PLANS, <br /> -- WIRING DETAIL&ISOMETRIC <br /> SHEET NUMBER: <br /> ISOMETRIC PLAN TOP PLAN BACK PLAN AREA OF WORK FP-03 of 06 <br />
The URL can be used to link to this page
Your browser does not support the video tag.