Laserfiche WebLink
PHOTOVOLTAIC SYSTEM SPECIFICATIONS: BILL OF MATERIALS MODULE, ARRAY WEIGHT (LOAD SYSTEM LEGEND ^_ <br /> SYSTEM SIZE: 5.330 KW DC EXISTING INTERIOR MAIN SERVICE PANEL&POINT 13 <br /> NUMBER OF MODULES 13 ZNSHINESOLAR ZXM7-SH108-410M CALC'S) �,.� <br /> 4.480 KW AC OF INTERCONNECTION.TIED TO EXTERIOR UTILITY <br /> MODULE TYPE&AMOUNT: (13)ZNSH NESOLAR ZXM7-SH108-410M NUMBER OF INVERTER 07 AP SYSTEMS DS3-S Number of Modules 13 M METER#76 368 580. Infinity_cola r <br /> MODULE DIMENSIONS: L/W/H 67.87"/44.64"/1.18" COMBINER PANEL 1 EATON BR STYLE 1 INCH LOAD CENTER Module Weight 45.19 LBS <br /> ( ) NEW VISIBLE,LOCKABLE,LABELED DISCONNECT INFINITY HOME SOLUTIONS <br /> 816L125RP Total Module(Array)Weight AC LOCATED WITHIN 10'FROM THE UTILITY METER <br /> INVERTER: (07)AP SYSTEMS DS3-S ( Y) 9 587.47 LBS 6405E MILL PLAIN <br /> AC DISCONNECT 1 30A NON-FUSIBLE AC DISCONNECT,240V PHONE:VERWA 98661 <br /> -0598 <br /> AHJ: CITY OF EVERETT Number of Attachment point 22 PHONE:1-800-818-0598 <br /> NUMBER OF CHASIS 22 IRON RIDGE BX CHASSIS Mounting System Weight 1.5 LBS © NEW DEDICATED PV SYSTEM COMBINER PANEL. INFINITY SOLAR.COM <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT NUMBER OF BLOCKS 87 IRON RIDGE BX CHASSIS (Per Module, <br /> WITHIN 10'OF UTILITY METER Mounting System Weight 33.00 LBS REVISIONS <br /> Total System Weight 13 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES 620.47 LBS WITH NEW(07)AP SYSTEMS DS3-S INVERTERS. Description Date Rev <br /> NOTE : (Module Weights Mounting eigSystem <br /> ht Weight) <br /> Initial Design 1/29/25 00 <br /> Weight at Each Attachment Point 26.70 LBS <br /> (Array Number o men <br /> ATTIC RUN-NO (A Weight/Numbf Attachment Point) <br /> ?6,, ® =FIRE PATHWAY <br /> ATTIC FAN-NO Module Area(67.87'X44.64") 21.04 SgFt <br /> SHUTDOWN-NO Total Array Area 273.52 SgFt 00 =ROOF OBSTRUCTIONS <br /> y Distributed Load Signature with Seal <br /> (Total system Weight/Total Array Area) 2.27 Per Sq Ft <br /> ❑ =BALLAST BAY <br /> Total Roof Area 2060 SgFt <br /> Total Percentage or Roof Covered o =RAFTER <br /> 6 TotalAayAreaITotaiRoofArea)'foo 13.28/0 <br /> =RACKING SYSTEM <br /> y O of =EXTERIOR RUN Project Name& <br /> ! Address <br /> , =CONDUIT ROOF TOP JUNCTION BOX <br /> Z <br /> W <br /> W W o <br /> ROOF SECTIONS Q Q C" <br /> N a Q z <br /> RooF#o1 MODULE-13 Q J <br /> SLOPE-10° <br /> o� AZIMUTH-137° 0 H W zp 2i <br /> of MATERIAL-ROLLED COMP Q co E d W <br /> Q� RAFTER SIZE&SPACING-2"X6"@ 60"O.C. Cl) Lu <br /> J oM W <br /> O Q <br /> U <br /> i <br /> 0 <br /> Sheet Name <br /> `' SITE PLAN <br /> Sheet Size <br /> ANSI B <br /> 0 11" X 17" <br /> � N Sheet Number <br /> O 11 <br /> t 0 ��\m��'lunpm�x�n���yr�� PV 1 1 <br /> y 0 NEW AC COMBINER PANEL ���� ����� <br /> CIRCUIT(S) <br /> — ——_ - NEW PV AC DISCONNECT GROUPED <br /> CIRCUIT#1 -07 MODULES WITH 04 MICROINVERTERS WITH SERVICE EQUIPMENT(VISIBLE, <br /> LOCKABLE,LABELED) <br /> CIRCUIT#2-06 MODULES WITH 03 MICROINVERTERS + <br /> EXISTING INTERIOR MAIN SERVICE PANEL <br /> &POINT OF INTERCONNECTION.TIED TO ������"l"°I°°�°"I"�°t���� <br /> SITE PLAN EXTERIOR UTILITY METER#76 368 580 <br /> 1 <br /> Pv tt SCALE:1/8"=V-0" <br />