My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3036 TULALIP AVE 2025 Plans 2025-12-02
>
Address Records
>
TULALIP AVE
>
3036
>
Plans
>
3036 TULALIP AVE 2025 Plans 2025-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2025 10:27:36 AM
Creation date
12/2/2025 10:26:41 AM
Metadata
Fields
Template:
Address Document
Street Name
TULALIP AVE
Street Number
3036
Permit
PV2501-008
Year
2025
Notes
Solar Installation
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MICROINVERTERS SPECIFICATION PV MODULE RATING @ STC Rooftop conductor ampacities designed in compliance with 120% RULE <br /> MICROINVERTER MAKE AP SYSTEMS MANUFACTURER ZNSHINESOLAR ZXM7-SH108-410M art. 690.8,Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 0 <br /> MICROINVERTER MODEL NO. DS3-S 310.16, Chapter 9 Table 4, 5, &9. Location specific BUS BAR RATING X 120%) - MAIN BREAKER RATING <br /> MAX.POWER-POINT CURRENT(IMP) 13.10 AMPS p p _ infinity cola r <br /> MAXIMUM AC OUTPUT 640 W temperature obtained from ASHRAE 2017 data tables - MAX. PV OCPD <br /> MAX INPUT VOLTAGE 60 V MAX.POWER-POINT VOLTAGE(VMP) 31.30 VOLTS INFINITY HOME SOLUTIONS <br /> MAX AC CURRENT 2.66 A OPEN-CIRCUIT VOLTAGE(VOC) 37.50 VOLTS (200A x 120%) - 200 = 40A 6405 E MILL PLAIN <br /> VANCOUVER WA 98661 <br /> MAX OUTPUT VOLTAGE 240 V NE:1-800-818-0598 <br /> SHORT-CIRCUIT CURRENT(ISC) 13.84 AMPS RECORD LOW TEMP -5°C INFFIINITY SOLAR COM <br /> NOM.MAX.POWER AT STC(PMAX) 410 WATT AMBIENT TEMP(HIGH TEMP 2%) 26°C THIS PANEL IS FED BY MULTIPLE SOURCES <br /> VISIBLE, LOCKABLE, LABELED DISCONNECT (UTILITY AND SOLAR) REVISIONS <br /> WITHIN 10' OF UTILITY METER MAX.SYSTEM VOLTAGE 15oov CONDUIT HEIGHT 7I8" <br /> Description Date Rev <br /> VOC TEMPERATURE COEFFICIENT -0.29%/°C ROOF TOP TEMP 48°C AC OUTPUT CURRENT 19A Initial Design 1/29/25 00 <br /> NOTE : CONDUCTOR TEMPERATURE RATE 90°C NOMINAL AC VOLTAGE 240V <br /> ATTIC RUN -NO MODULE: (13)ZNSHINESOLAR ZXM7-SH108-410M <br /> SHUTDOWN -NO INVERTER: (07)AP SYSTEMS DS3-S NOTE: (SOLAR PV SYSTEM EQUIPPED WITH <br /> RAPID SHUTDOWN)NEEDS TO BE LOCATED Signature with Seal <br /> POINT OF INTERCONNECT,LOAD SIDE <br /> WITHIN 3FT OF AC DISCONNECT. EXISTING 240V/200A BUS BAR RATING, <br /> MAIN SERVICE DISCONNECT,SINGLE <br /> NOTE: -TANDEM BREAKERS TO BE USED TO PHASE,WITH A 200A MAIN BREAKER <br /> MAKE ROOM FOR PV CIRCUIT BREAKER UTILITY COMPANY-PUD#1 <br /> SNOHOMISH COUNTY Project Name& <br /> UTILITY METER#76 368 580 Address <br /> EXISTING <br /> BI-DIRECTIONAL <br /> UTILITY METER, <br /> (13) ZNSHINESOLAR ZXM7-SH108-410M 1-PHASE,3W, U <br /> (07) AP SYSTEMS DS3-S INVERTERS (N)125A COMBINER PANEL, (N)BLADE TYPE 120V/240V w <br /> 240V,3W,1-PHASE NON-FUSIBLE AC DISCONNECT 0 <br /> BRANCH 1-07 MODULES WITH 04 MICRO INVERTERS NEMA 3R 30A 2P 120/240VAC w <br /> (VISIBLE,LOCKABLE,LABELED) Q rn Q C' <br /> 200A U t2 Q z <br /> !---- E--{ Q � wJ <br /> C) z Q <br /> (E)LOADS z 1-- LU O <br /> 1 ( (N)PV BREAKER CO LU <br /> CO � Lu <br /> J (N)JUNCTION BOX 0 J M LU <br /> N N N 600 V,NEMA 4 15A LL <br /> UL LISTED 30A/2P <br /> ——— �F 1 5A L1 �� U <br /> BRANCH 2-06 MODULES WITH 03 MICRO INVERTERS Li L1 L2 <br /> L2 L2 <br /> L1 L1 <br /> FF <br /> L2 L2 F_ — -- ---- G --- ----- ------- <br /> --- �— — ---- — c I L G Sheet Name <br /> L _ J L — J L _ J J 3-LINE <br /> DIAGRAM <br /> EXISTING GROUNDING <br /> 1 2 3 3 ELECTRODE SYSTEM Sheet Size <br /> ANSI B <br /> 11" X 17" <br /> WIRE MAX PARALLEL C.0 PV CURB. TOTAL CONT. CURR WIRE TEMP CONDUIT WIRE DERATED MAX. CONT. LENGTH VOLTAGE <br /> TAG# DEVICES RATING MULT CURR X 125% WIRE SIZE\TYPEWMP. OCP #C.C.C. CONDUIT DE-RATE: FILL: AMP: AMPACITY CURRENT GND FT. MAX DROP(%) Sheet Number <br /> O04 x 2.66 x N/A = 10.64A 13.30A #10\THWN\40A @90°C 15A 2 IN AIR TRUNK CABLE 1.00 x 1.00 x 40A 40.00A 10.64A #6 AWG 20 0.18 E 1 .1 <br /> 4) 04 x 2.66 x N/A = 10.64A 13.30A #10\THWN\40A @90°C 15A 4 3/4" EMT 1.00 x 0.80 x 40A 32.00A 10.64A #8 AWG 50 0.46 0.80< <br /> 2 <br /> O07 x 2.66 x N/A = 18.62A 23.28A #10\THWN \35A @75°C 30A 2 3/4" EMT 1.00 x 1.00 x 35A 35.00A 18.62A #8 AWG 10 0.16 <br />