Laserfiche WebLink
F R A N K L I N 6255artr ,,,manna FH 42;_5 527-3324 <br /> ENGINEERING vLjYr: 2��2 FA�� �2� �2 _��2Y2 <br /> K. rLIl_nd, /'A 9;F50`55 notaIi rarnkiinCn0.com <br /> February 24, 2022 <br /> ENVELOPE SUMMARY <br /> RE: Smartcap Baker View Logistics Center <br /> 1215 801 Street <br /> Everett, WA 98203 <br /> New semi-heated warehouse building. Project complies with 2018 WSEC, Commercial <br /> Provisions, using the Component Performance approach. Project complies with the definition <br /> of semi-heated space per section C202. Walls are exempt from insulation per section <br /> C402.1.1.2. Warehouse is not cooled and the heating system will be other than electric <br /> resistance with a maximum output of 8 Btuh/SF. <br /> Roof: R-38 minimum rigid insulation above roof deck. U=0.027, default <br /> Table Al02.2.6(1) <br /> Wall: Exempt <br /> Slab on Grade: No Insulation, F=0.73, default Table A106.1 <br /> Doors (Swinging, Opaque): Insulated metal, U=0.37, default Table A107.1(1) <br /> Doors (Roll-up, Opaque, 9 x 10): Insulated metal, min. R-10, U=0.17, default Table <br /> Al 07.1(4) <br /> Doors (Roll-up, Opaque, 12 x 14): Insulated metal, min. R-5, U=0.34, default Table <br /> Al 07.1(4) <br /> Vertical Glazing (Fixed): NFRC certified assembly, U=0.38, SHGC=0.40 <br /> Vertical Glazing (Entrances): NFRC certified assembly, U=0.60, SHGC=0.40 <br /> Skylights: Skylights: NFRC certified assembly, U = 0.50, SHGC=0.35, VT=0.50 <br /> Please note that these values are minimum insulation requirements for code compliance. <br /> Higher insulation values may be installed. SHGC = Solar Heat Gain Coefficient. VT= Visible <br /> Transmittance. <br />