Laserfiche WebLink
E <br />F <br />G <br />70-SWBD-0202 <br />1 <br />DOWNSPOUT <br />BUILDING <br />FOUNDATION <br />DB0004ADB0001A <br />CTC020 <br />CTS020 <br />CTP1020 <br />DB0012DB0011A <br />2 2 2 <br />3 3 <br />3 <br />3 <br />3 <br />3 <br />3 <br />4 <br />4 <br />44 <br />5 <br />CONDUIT ROUTE OUT THE <br />BOTTOM OF PULL BOX AND <br />INTO DUCT BANK CURB <br />BELOW, NUMBER AND SIZE <br />PER RACEWAY SCHEDULE <br />CONDUIT ROUTE OUT THE <br />BOTTOM OF PULL BOX AND <br />INTO DUCT BANK CURB <br />BELOW, NUMBER AND SIZE <br />PER RACEWAY SCHEDULE <br />CONDUIT ROUTE OUT THE <br />BOTTOM OF PULL BOX AND <br />INTO DUCT BANK CURB <br />BELOW, NUMBER AND SIZE <br />PER RACEWAY SCHEDULE <br />PULL BOX PULL BOX PULL BOX PULL BOX <br />5 <br />5 <br />6 6 <br />EALNIO N GTR <br />SRFOE <br />SPSTA EREERSGEITE G ID NTNOE <br />HOFWAS <br />N <br />I <br />55755JAMESA.TU <br />C <br />KERPLANS ISSUED FOR <br />BID <br />ACTION DATE APRVD ACTION DATE APRVD ACTION DATE APRVD <br />CONST RECORD <br />Drawing <br />Sheet No. <br />Of Total <br />Designed <br />Drawn <br />Checked <br />Design Review Level <br />500 <br />Plot dateFilepath\FilenameWO# UP-3525 <br />PORT GARDNER <br />everettwa.gov <br />3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 <br />NO. DATE APRVD REVISION <br />12/2/2024 ZB <br />STORAGE FACILITY - <br />FACILITY CONSTRUCTION PACKAGEAutodesk Docs://157889 - PGSF/E-3525-70V23.rvt8/6/2025 3:55:11 PMEP-70-4003 <br />446 <br />ELECTRICAL POWER <br />OMES BUILDING EXTERIOR WALL ELEVATION <br />C. BJORKLUND <br />S. CANAS <br />J. TUCKER <br />EP-70-2001 SCALE: 1/2" = 1'-0" <br />1 ELEVATION <br />KEYNOTES: <br />1 APPROXIMATE GRADE LEVEL. <br />2 CONTRACTOR TO PROVIDE ENGINEERED EQUIPMENT <br />SUPPORT FOR PULL BOXES. PULL BOXES AND ALL OTHER <br />EQUIPMENT TO BE FREE STANDING AND SUPPORTED <br />INDEPENDENTLY OF THE BUILDING WALL. REFER TO <br />SPECIFICATIONS AND SEE ELECTRICAL STANDARD DETAIL <br />E25001. <br />3 CONTRACTOR TO PROVIDE TRAY AND RACEWAY SUPPORT <br />PER SPECIFICATIONS. MUST BE SUPPORTED <br />INDEPENDENTLY OF BUILDING WALL OR APPROVED BY <br />ENGINEER. <br />4 SEAL ALL DUCT BANKS PER SPECIFICATIONS. <br />5 PROVIDE CUTOUT OPENING IN WALL FOR CABLE TRAY TO <br />EXIT ELECTRICAL ROOM. OPENING TO BE 1" BIGGER THAN <br />CABLE TRAY ON ALL SIDES. SEAL CABLE TRAY OPENING <br />PER SPECIFICATIONS. <br />6 MAINTAIN 24" MINIMUM DISTANCE AT FACE OF CONCRETE <br />BETWEEN DUCT BANKS DB0001A AND DB0004A. <br />CLEARANCE DOES NOT NEED TO BE MAINTAINED AT <br />MANHOLE (MH0101) ENTRY <br />GENERAL NOTES: <br />1. CONDUIT ROUTING SHOWN IS NOT ALL INCLUSIVE AND <br />FOR DEMONSTRATION PURPOSES ONLY. CONTRACTOR <br />SHALL BID THEIR OWN MEANS AND METHODS OF THE <br />COMPLETE CONDUIT ROUTING. <br />2. SEE CABLE AND RACEWAY SCHEDULES FOR CABLES AND <br />CONDUITS COMING OUT OF THE ELECTRICAL ROOM <br />THROUGH THE NORTH WALL OF OMES BUILDING. <br />3. FINAL ARRANGEMENT OF INDIVIDUAL CONDUIT <br />PENETRATIONS THROUGH OMES NORTH WALL TO BE <br />DETERMINED BY CONTRACTOR. <br />4. SEE SECTION 2 / EP-70-2001 FOR INDIVIDUAL CONDUIT <br />DETAIL. <br />09/03/2025 ZB