Laserfiche WebLink
2 ROWS BN TO TOP PLATES.AT THE MIN DIMENSION OF A STAG PLYWD AS <br /> 8'-3/4"TALL WALLS,INSTALL SINGLE PIECE OF WALL SHTG SHALL BE SHOWN W/FACE <br /> BN ROW ON LOWER WALL PL CL 12".USE PARTIAL LENGTH STAG PLYWD AS SHOWN FN GRAIN PERP TO <br /> SHEETS @TOP OF WALL ONLY FN WITH FACE GRAIN PERP FRAMING <br /> TO FRAMING ``'' <br /> BN i <br /> ALIGN HORIZ JOINTS ON <br /> SOLID STUD WIDTH BLKG �T1 it d <br /> 2 Z E <br /> WHERE SP SHEATHING OCCURS ROOF FRMG,TYP W w y a 3 <br /> ON EA SIDE OF WALL,STAG VERT <br /> SHEET JOINTS ON DIFFERENT BLKG @ WALL LINE p <br /> STUDS EA SIDE Y <br /> z'z <br /> / B •I 20 6 <br /> N <br /> JOISTS,TYP NOTES: `1 0`�°in R <br /> BN TO PERIMETER OF ALL 1 ALL ROOF SHEATHING TO BE 15/32"CDX,5 PLY MIN.PANEL INDEX 32116. <br /> SHEETS&TO ALL VERT 1. ALL FLOOR SHEATHING TO BE 23/32"APA RATED STURD-I-FLOOR,24"OC, 2.. USE BN OF 8d @ 6"OC @ ALL PANEL EDGES,SHEAR WALLS,TIES&BLKG.FN TO ALL INTERIOR <br /> MEMBERS OF 4X OR GREATER EXPOSURE 1,TONGUE-AND-GROOVE. BEARINGS W/8d @ 6"OC ON ROOFS. <br /> WIDTH 2. GLUE-FASTENED INSTALLATION-USE ADHESIVE COMPLYING WITH APA 3. PLACE PANELS CONTINUOUS OVER TWO OR MORE SPANS AND PROVIDE 1/8"GAP AT ALL PANEL <br /> SPECIFICATION AFG-01.USE SIMPSON STRONG-TIE QUICK DRIVE WSNTL EDGES. <br /> #8 FLAT HEAD SCREWS PER ICC-ES ESR-1472(OR EQV.)W/MINIMUM 4. DO NOT BREAK ANY FACE PLYS W/NAIL HEADS.THE MIN EDGE DISTANCE FOR NAILS SHALL BE <br /> FN TO ALL INTERIOR CONTACTS 1-1/4"PENETRATION INTO FRAMING MEMBER.BN OF 6"OC @ ALL PANEL 3/8"IN THE PLYWD&IN THE RECEIVING MEMBER. p11DREH'@ <br /> EDGES,SHEAR WALLS,TIES&BLKG.FN TO ALL INTERIOR BEARINGS @ 5. ICBO ACCEPTED&APA RATED PERFORMANCE RATED SHEATHING PANELS MAY BE �'pF IVAS111� <br /> 3. PLACE PANELS CONTINUOUS OVER TWO OR MORE SPANS AND PROVIDE SUBSTITUTED FOR PLYWD.PANEL THICKNESS&SPAN RATING SHALL BE EQUAL TO THAT NOTED G =6 } <br /> USE FULL SHEETS WHERE 1/8"GAP AT ALL PANEL ENDS. ON THESE PLANS. ? r <br /> POSSIBLE 4. SET SCREW HEADS FLUSH WITH PLYWOOD SURFACE.THE MINIMUM <br /> EDGE AND END DISTANCE FOR SCREWS SHALL BE 3/8"IN THE PLYWD& O ROOF SHEATHING P 30695 Q� <br /> IN THE RECEIVING MEMBER. <br /> ALIGN BOTTOM OF SP PANEL 5. ICBO ACCEPTED&APA RATED PERFORMANCE RATED SHEATHING GRF <br /> W/BOTTOM OF MUD PLATE PANELS MAY BE SUBSTITUTED FOR PLYWD.PANEL THICKNESS&SPAN AL <br /> ON SOLE PLATE).CENTER BN ROW <br /> ON MUD PL CL RATING SHALL BE EQUAL TO THAT NOTED ON THESE PLANS. S�IS(24 <br /> 3l4" <br /> BN <br /> O WALL SHEATHING O CONVENTIONAL FLOOR SHEATHING LAYOUT STUD,JST, <br /> SP <br /> RAFTER,OR BILK <br /> NOTE:PROVIDE 1/8"GAP <br /> SPJT BETWEEN SHEETS AT JOINTS <br /> 3/8' 3/8" 3/4" <br /> BN BN FIN `^ <br /> TOP PLATES V J <br /> J <br /> (N)RAFTER PER PLAN <br /> SP SP <br /> (N)2x CONT PURLIN, STUD,JST, SP <br /> MATCH RAFTER STUD,JST, RAFTER, <br /> DEPTH,UON RAFTER, OR BILK <br /> BORED HOLE MAX STUD WALL FRMG OR BLK <br /> (N)2.4 STRUT @ 4'-0"OC (N)2x4 CLEAT W/(3) W <br /> i6d EA END DIAMETER 40 PERCENT PER PLAN <br /> MAX(UON)TO WALL PL OF STUD DEPTH <br /> BELOW W/A34.INSTALL 2 SP NAILING LLI 0 <br /> GREATER THAN 45°TO <br /> HORIZONTAL&MAX r, <br /> UNBRACED LENGTH 8' U M <br /> 5/8"MIN TO EDGE Q <br /> ALTERNATE DETAILS -"MIN TO EDGE LAP PLATES PER SD 2 z w <br /> 00 <br /> BORED HOLES SHALL Q Lu '� <br /> NOT BE LOCATED IN THE <br /> SAME CROSS SECTION ♦/� <br /> OF CUT OR NOTCH IN v J <br /> STUD o USE A34 @ OPNG OV/7'-0" Lu m 3: <br /> (N)RAFTER PER PLAN T&B,TYP J <br /> 2X BILK @ SP JOINTS& <br /> (N)2x CONT PURLIN, CEILING LINES L <br /> MATCH RAFTER DEPTH, IF HOLE IS BETWEEN 40 AND 60 PERCENT (O� 1— Ire <br /> UON NOTCH MUST NOT OF STUD DEPTH,THEN STUD MUST BE HEADERS PER PLAN. Lu W <br /> EXCEED 25 PERCENT OF DOUBLE AND NO MORE THAN TWO [)1 N 0.(N)2x4 STRUT @ 4'-0..OC (2)-16d STUD DEPTH SUCCESSIVE STUDS ARE DOUBLED AND 5-16d AS SHOWN EXCEPT USE '^ <br /> MAX(UON)TO WALL PL SO BORED A34 LL v HEADERS OW 7'-0"LONG )BELOW W/A34.INSTALL OR WHERE 16d CAN NOT BE \\ <br /> GREATER THAN 45°TO USED O Lo / Q <br /> HORIZONTAL&MAX <br /> UNBRACED LENGTH 8' 2-10d TN,T&B 1-2X STUD, YP <br /> O NOTCHING&BORING OF STUDS 2-2XSTUDS WHERE NOTETDON LJ LJ� <br /> PLANS <br /> 10 PURLIN LINE SUPPORT DOUBLE 2X SUB-SILL @OPNG Q <br /> 3/4^=1'0^ ABOVE FLOOR <br /> MIN SPACING TO BE 3x NOTCHES&PENETRATIONS z <br /> DIAMETER OF LARGER GREATER THAN 1/3 WIDTH OF <br /> PLYWOOD AS PENETRATION TOP PLATE ARE NOT ALLOWED <br /> NAIL AS A MULTIPLE STUD <br /> OCCURS <br /> �I KING STUDS FOR HEADERS LESS THAN T-0"USE <br /> ( <br /> U (5)-8d 5)-i6d SINGLE 2X TRIMMER OTHERWISE <br /> w 1/3 USE DOUBLE 2X TRIMMER,UON <br /> 0 <br /> KING STUD PER TABLE BELOW <br /> w BEAM OR HEADER <br /> m 16d 12"OC ALL PENETRATIONS <br /> > @ MAX DIAMETER OF <br /> LL 3x CRIPPLE,TYP READ TO BE W/IN MID PENETRATION TO BE m <br /> UON 113 OF TOP PLATE 113 WIDTH OF TOP WALL OPENING KING STUD REQUIREMENTS <br /> PLAN SECTION <br /> OI STUD WALL OPENING WIDTH(FT) o m <br /> AT CORNER OF WALL STUD SIZE <br /> 07 TOP PLATE PENETRATIONS HEIGHT a'-o" s'-o" s'-o" o'-o^ a <br /> 0 2x(STUD WIDTH) 2X4 2X4 DBL 2X4 (3)2X4 4X6 <br /> KING STUD EA SIDE 81-0^ <br /> 2X6 <br /> 2X6 2X6 2X6 2X6 DB 00 L <br /> (5)-i6d EA SIDE SOLID PLYWD <br /> BEAM OR HEADER FILLER AS 2X4 DBL 2X4 (3)2X4 4X6 4X6 p <br /> ¢' REQD @ GLB 10'-0" p <br /> 2X6 2X6 2X6 DBL2X6 DBL 2X8 <br /> — 3x CRIPPLE, MIN SPACING TO BE 3X 'c <br /> O TYP UON DIAMETER OF LARGER 4 1/2"MIN p <br /> 16d WALL FRAMING ELEVATION z <br /> 12"OC PENETRATION 9"MAX Cn N <br /> ELEVATION EA DE SECTION O <br /> N PERPENDICULAR TO WALL <br /> > i6d 4'-0"MIN i6d Lu <br /> O BEAM OR HEADER TO WALL 1s"oc 1s"oc <br /> 16-16d MIN,STAG NAILS EA N <br /> �. 1/2"=1'-0" 1/3 SIDE OF PLATE OR AS p <br /> NOTED ON PLANS <br /> (7 <br /> ALL PENETRATIONS REQD TO BE <br /> W/IN MID 113 OF SILL PLATE DBL TOP PLATE <br /> MAX DIAMETER OF <br /> PENETRATION TO BE WALL STUDS DATE g/15/2024 <br /> 1/3 WIDTH OF SILL PLATE <br /> o PROVIDE AS EA SIDE OF NOTCHES& DRAWN <br /> p <br /> PENETRATIONS GREATER THAN 1/3 NOTES: KBM <br /> WIDTH OF SILL PLATE 1.SPLICES TO OCCUR ONLY OVER CENTER LINE OF STUD. <br /> 78 JOB NO <br /> C4651066.00 <br /> Og SILL PLATE PENETRATIONS 40 LAP SPLICE SHEET C <br /> a S0.2 <br />