My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
215 SHUKSAN WAY 2023 Plans 2025-12-12
>
Address Records
>
SHUKSAN WAY
>
215
>
Plans
>
215 SHUKSAN WAY 2023 Plans 2025-12-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2025 10:59:44 AM
Creation date
12/12/2025 10:59:12 AM
Metadata
Fields
Template:
Address Document
Street Name
SHUKSAN WAY
Street Number
215
Permit
K2307-020
Year
2023
Notes
BUILDING 1 FIRE PROTECTION SYSTEM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 <br /> PROJECT LOCATION UNDERGROUND NOTES: GENERAL NOTES: SCOPE OF WORK: <br /> DRAWING INDEX: SYMBOLS: 1.ALL SYSTEMS TO BE HYDROSTATICALLY TESTED AT 200 PSI OR 50 PSI OVER FIRE SPRINKLERS:OWNER IS CONSTRUCTING A(3)STORY STEEL&CONCRETE <br /> 0 EV-CM-FB-3-FIRE SITE PLAN AND NOTES 1.ALL UNDERGROUND HYDRANTS,FDC,AND FIRE CIVIL PIPING TO BE THE SYSTEM PRESSURE,WHICHEVER IS GREATER.FOR 2 HOURS. BUILDING. <br /> EV-CM-FB-00-FIRE PROJECT DETAILS DONE BY OTHERS.CONTRACTOR TO BE STATE LICENSED AND CERTIFIED r SWAY BRACING 2.PIPING: <br /> EV-B1_FB-0I-FIRE STANDPIPE ISO TO INSTALL UNDERGROUND PIPING PER WAC 212-80.SEE CIVIL PERMIT FOR -1"PIPE TO BE SCHEDULE 40 BLACK STEEL PIPE ANSI/ASTM A135 OR A795. -INSTALL(3)WET FIRE SPRINKLER SYSTEMS,ONE ON EACH FLOOR,L01,L02,&L03. <br /> V '" v EV-B1_FB-02-FIRE STANDPIPE SECTION DETAILS AND PIPING. f PIPE HANGER -1-1/4"TO 6"PIPE TO BE SCHEDULE 10 BLACK STEEL PIPE ANSI/ASTM A135 OR A795 <br /> 0 - EV-BI-FB-10-1-FIRE SPRINKLER PLAN LEVEL 01 3.FITTINGS: -INSTALL A NEW MANUAL WET CLASS I STANDPIPE WITH 2.5"HOSE VALVES <br /> EV-B1-FB-10-2-FIRE SPRINKLER PLAN LEVEL 01 2.PIPE TYPE AND CLASS TO MEET LOCAL JURISDICTION APPROVAL. THREADED FITTINGS TO BE BLACK DI FITTINGS THROUGHOUT THE BUILDING.THERE WILL BE(3)VERTICAL STANDPIPE INTER <br /> EV-B1_FB-20-1-FIRE SPRINKLER PLAN LEVEL 02 �� PIPE HANGER W/BRANCH LINE RESTRAINT GROOVED FITTINGS TO BE PAINTED VICTAULIC FIRELOCK OR EQUAL CONNECTED AT THE BASE ON LEVEL 1.HOSE VALVES WILL BE INSTALLED ON THE FLOOR <br /> EV-BI-FB-20-2-FIRE SPRINKLER PLAN LEVEL 02 3.ALL UNDERGROUND PIPING SHALL HAVE 3 FEET MINIMUM BURY BELOW WELDED OUTLETS BY MERIT OR EQUAL LANDING.EACH VERTICAL RISER WILL INCORPORATE AN ISOLATION VALVE W/TAMPER. <br /> :a EV-B1-FB-30-1-FIRE SPRINKLER PLAN LEVEL 03 THE FROST LINE(TO TOP OF PIPE). DI UNDERGROUND PIPING,BY OTHERS 4.WORKING PRESSURES <br /> U <br /> - -_, KEY 4.ALL UNDERGROUND PIPING SHALL BE UL LISTED AND/OR FM APPROVED -SCHEDULE 10&40 PIPE RATED FOR 300 PSI <br /> 0 - <br /> FOR FIRE PROTECTION.ALL PIPING WITHIN 5'-0" FIRE SPRINKLER SYSTEM PIPING OF BLDG TO BE MIN CLASS -FIRELOCK FITTINGS AND COUPLINGS RATED FOR PSI DESIGN CRITERIA: <br /> 6" ULIC/GLOBE SERIES O PIPE STAND 52 DUCTILE IRON. 5.ALL SEISMIC BRACING ASSEMBLIES AND HANGERS TOO BE INSTALLED PER --PER NFPA 13(2016),NFPA 14(2016),AND CITY OF EVERETT. <br /> SERIES <br /> UMC UNIVERSAL FLEXIBLE COUPLING NFPA 132016 EDITION AND AS NOTED ON PLANS. <br /> Q, MANIFOLD CHECK ASSEMBLY --BUILDING IS NOT CONSIDERED A HIGH RISE BUILDING. <br /> 0 5.ALL UNDERGROUND PIPING SHALL BE RESTRAINED IN ACCORDANCE 6.ALL MATERIALS AND EQUIPMENT TO BE UL LISTED OR FM APPROVED UNLESS --THE STANDPIPE SYSTEM TO BE DESIGNED,INSTALLED AND TESTED IN ACCORDANCE <br /> O 2"TO HUB DRAIN WITH THE SPECIFICATIONS AND NFPA 24(LATEST EDITION). OTHERWISE NOTED. <br /> T � O VALVE WITHAMPER BUTTERFLY _1_ RIGID COUPLING 7.SPRINKLER DEFLECTOR AND LOCATIONS SHALL BE DESIGNED IN ACCORDANCE WITH NFPA 14,(2016). <br /> O6"BACKFLOW 6.ALL UNDERGROUND PIPING SHALL BE HYDROSTATICALLY TESTED AT NOT HYDRAULIC NODE WITH NFPA 13-2013. <br /> 04 <br /> xx 3O 4"CHECK VALVE LESS THAN PSI OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 8.OWNER IS RESPONSIBLE FOR MAINTAINING TEMPERATURES ABOVE PIPING DEGREES LABS&SHELL SPACES <br /> ORDINARY GROUP 2 HAZARD <br /> VICINITY MAP: PSI FOR TWOO H HOURS IN ACCORDANCE WITH NFPA 24(LATEST EDITION). FIRE SPRINKLER RISER ROOM TO PROTECT ANY WET SUPPLY ELECTRIC BELL(BY OTHERS) 9.BUILDINGS STEEL&CONCRETE STRUCTURE&NON-COMBUSTIBLE TYPE A FROM FREEZI --ZING. DESIGN DENSITY:0.17 GPM/3000 SF <br /> S 4O 1"AUX DRAIN WET SYSTEM <br /> 7.ALL UNDERGROUND PIPING SHALL BE FLUSHED IN ACCORDANCE WITH 10.OCCUPANCY GROUPS A,B, MAXIMUM HEAD SPACING 130 SO FT <br /> NFPA 24(LATEST EDITION).FLOW THE REQUIRED RATE UNTIL WATER IS FIRE DEPARTMENT CONNECTION 11.NOTIFICATION IS PROVIDED BY INTERIOR AND EXTERIOR HORN&STROBE <br /> CLEAR AS INDICATED BY NO COLLECTION OF FOREIGN MATERIAL IN (SIDEWALK),BY OTHERS (BY OTHERS).DETECTION DEVICES LIKE SMOKE DETECTORS SHALL BE --MECHANICAL ROOMS.ELECTRICAL ROOMS,&GENERAL STORAGE <br /> BURLAP BAGS AT OUTLETS. PROVIDED AND INSTALLED BY OTHERS. ORDINARY GROUP 1 HAZARD <br /> EXISTING FIRE HYDRANT 12.ALL ELECTRICAL WIRING&MATERIAL SHALL BE LISTED IN ACCORDANCE WITH DESIGN DENSITY: 1 H GPM/1500 SF <br /> 4"- 490 GPM 10"-2,400 GPM NFPA 70(NEC)LATEST EDITION.(BY OTHERS). WET SYSTEM,UNLESS NOTED BELOW <br /> 6"- 880 GPM 12"-3,520 GPM 13.ALL PIPE LENGTHS TO BE: <br /> fZ g g g g g 2 8"-1,560 GPM �$ POST INDICATOR VALVE(PIV) THREADED PIPE:CENTER TO CENTER OF FITTING <br /> w w w w w w -GROOVED PIPE CENTER OF OUTLET TO END OF PIPE --OFFICES,COMMON AREA,&PUBLIC PLACES <br /> 1 6'/= y y In 4' y 8.ALL UNDERGROUND PIPING SHALL BE STERILIZED PER LOCAL I.l ELECTRIC BELL(WIRING BY OTHERS) 14.FIRE SPRINKLER SYSTEM TO BE DESIGNED INSTALLED&TESTED IN ACCORDANCE LIGHT HAZARD <br /> rn rn rn 1-6% m rn m JURISDICTION REQUIREMENTS. Yla WITH NFPA 132016 EDITION. DESIGN DENSITY:0.10 GPM/1500 SF <br /> J a J J w a w w FLANGED CONNECTION 15.ALL ORDINARY TEMPERATURE SPRINKLERS WILL BE LOCATED AT LEAST 12" WET SYSTEM <br /> Y d Y Y Y d Y Y <br /> AWAY FROM ANY EDGE OF A DIFFUSER&6"AWAY FROM LIGHTS(0-250W). MAXIMUM HEAD SPACING 225 SQ FT <br /> Q o z o z SPECIAL NOTES: o- PART TAG(SEE PART TABLE ON SAME SHEET) 16.SPRINKLER TYPE AND SPACING REFER TO THE SPRINKLER LEGEND&SPACING <br /> 1.REMOTE FDC BY OTHERS SHALL BE LOCATED A MINIMUM OF 3 FT AWAY NOTES ON THE PLANS. <br /> yo. moo. ya moo. Na �a �a ya SHRUBS,PARKING SPACES,ETC. SEISMIC BRACING: <br /> N> ? a. �> ? FROM ANY DOOR OPENING.FDC SHALL NOT BE OBSTRUCTED BY TREES, 17. -ALL PIPING TO BE BRACED PER NFPA 13,2016 EDITION <br /> o ion om o� x cp o� io o� o� <br /> 6„ w T� -9w� w m 6„ Iu" T� w°i w°9 x-x Ts CENTERLINE OF PIPE TO BOTTOM OF -PER NFPA 13,SECTION 9.3.6.5 RODS LESS THAN 6"SHALL NOT REQUIRE BL <br /> 2-7 > > > 2 >O1 >°' >O1 DECK RESTRAINT <br /> z Jx J x J x w x J x J x 2.ALL PAINTING OR LABELING OF FIRE SPRINKLER PIPING,IF REQUIRED, <br /> ❑ TO BE DONE BY OTHERS. 18.TYPICAL HANGERS WILL BE HILTI KH-EZ I OR DEWALT EQUAL TO PAN-DECKING WITH PROJECT HEAD COUNTS: <br /> ` CONCRETE,BEAM CLAMPS,OR SAMMY EXPRESS TO ROOF PAN DECKING. <br /> P 1 e 1 mO 3. IT IS THE OWNER'S RESPONSIBILITY TO ENSURE THAT THE STRUCTURE x-x FF CENTERLINE OF PIPE ABOVE FINISHED 19.SHINN SCOPE STARTS 12"INSIDE RISER ROOM AT FLANGE. SYM MFG TYPE SIN# -FACTO THR TEMP FINISH QTY <br /> SHOWN ON THE CONTRACT DRAWINGS CAN ADEQUATELY SUPPORT ALL FLOOR 20.ALL SYSTEMS TO BE MONITORED 24 HRS A DAY BY CENTRAL STATION-(BY OTHERS). Q RELIABLE RA1425 FIFR56 5.6 112 155°F BRASS 473 <br /> 2 2 2 2 �2 2 FIRE SPRINKLER PIPE AND SEISMIC LOADS. 0 RELIABLE RA1425 FIFR56 5.6 1/2 200°F BRASS 11 <br /> A WATER SUPPLY: <br /> 7 PLAN VIEW DETAIL ® RELIABLE RA1414 FlFR56 5.6 1/2 155°F CHROME 156 <br /> 3 5 O <br /> �7 O �O Q 5.ALL WIRING OF FP SYSTEM COMPONENTS TO BE DONE BY OTHERS. � SOURCE: Seagen Flow Test Report 3 O 0111 <br /> STATIC PSI: 92 PSI 0 RELIABLE R5714 F3QR56 DRY 5.6 1 200°F CHROME 2 <br /> Q 5 5 5 5 6.RELOCATING EXISTING OR NEWLY INSTALLED PIPING FOR OTHER TRADES RESIDUAL: 89 PSI • RELIABLE R3415 G5-56 5.6 1/2 165°F WHITE 84 <br /> IS EXCLUDED. SECTION DETAIL ARROW POINTS FLOW: 903 GPM <br /> 6"Riser Manifold W Riser Manifold X.XX VIEW DIRECTION ® RELIABLE R504 WP56C 5.6 1/2 165°F BRASS 7 <br /> 10-3 10-3 8.FIRE SPRINKLER RISER MANIFOLD SHALL BE BRACED TO FLOOR AND/OR LOCATION: Fire Hydrant RELIABLE R501 WP56 VSW 5.6 112 165°F CHROME 7 <br /> TO FDC/SUPPLY SEE CIVIL SHEET C38 DATE: 1-4-23 <br /> RISER ISO: RISER DETAIL: WALL PER NFPA#13-2016. TOTAL 750 <br /> N SPRINKLERS SHOWN FOR VISUAL REPRESENTATION ONLY,SPRINKLER HEIGHT PER NFPA 13 <br /> AA AB AD AF1/2 AG AK AK1/2 AL AL1/2 AM AN <br /> Permit#: K2307-020 <br /> M Site Address: 215 Shuksan Way <br /> Applicant: Shinn Mechanical <br /> Application Date:07/28/2023 <br /> B1-ROOF Description: Building 1 Fire Protection System <br /> L Review Status: 1 st Review by City&Peer Reviewers <br /> Review Date: 04/08/2024 <br /> K <br /> EVERETT <br /> J 61-LEVEL 03 Everett Fire Dept.Permit Review <br /> 36-2 _ _ Status:Approved <br /> IT Reviewed By:KBrown <br /> 04/08/2024 8:50:15 <br /> AM <br /> 1 1 1 1 l 1 1 1 <br /> APPROVED <br /> PUBLIC WORKS DEPARTMENT <br /> BY:THerman <br /> H DATE:04/10/2024 <br /> CITY OF EVERETT REVIEWED FOR PERMIT <br /> B1-LEVEL 02 <br /> G <br /> FPET NICET#106245 LEVEL IV,msuE <br /> Fi 8821-1119-C vlel3'was m. <br /> SHIN060 M1 iP Inc. <br /> 080pP <br /> B1-LEVEL 1 _ <br /> 18.4. <br /> E ....ouo4/.....:r.Y <br /> Bl SectionIINN <br /> 0 2 4 8 16 D <br /> SCALE 1/8"=1'-0" nvo <br /> ❑ B11 CRITICAL DWG: <br /> ❑Waste Bldg WA FIRE PROTECTION <br /> C B5 b Seagen SITE LOCATION: COVER PAGE 131 <br /> YDE.AbMfg/FDP <br /> Warehouse FIRE SPRINKLER PLAN <br /> EVERETT,WA <br /> ENGINEERING APPROVAL: SITE CODE: FILE NUMBER: SCALE: ORIGINATION DATE: <br /> 64 N SAM HUBALLA <br /> CUB 02-22-2023 EV FP 0.30-B1 Cover 1/8"=V-0" 02/22/2023 <br /> B C PERMIT REVISION SET N'A 04/04/2024 ALO SHH QUALITY APPROVAL: BUILDING: SEAGEN DRAWING NUMBER: REVISION: <br /> N/A 1 <br /> YD B PERMIT SET NA 07/25/2023 ALO SHH A PROGRESS SET FOR GMP NA 02/22/2023 ALO SHH EHSSAPPROVAL: FLOOR: EV-CM-F✓R <br /> -3-FIRE C <br /> A KEY PLAN REV REVISION DESCRIPTION CHANGE CONTR DATE I DRN APVL WA 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.