2 3 4 5 <br /> 1 <br /> E" SHEET NOTES <br /> (E)PANEL'P11' ----------- <br /> ------------------------— <br /> (E)PANEL'P10' 1. COORDINATE INSTALLATION OF ALL CONDUIT,CABLING,AND <br /> OTHER COMPONENTS WITH ARCHITECT,OWNER&PUD PRIOR TO <br /> ROUGH-IN. <br /> d 3 3 4 <br /> 2. PROVIDE GUYING/BRACING FOR PORTABLE SERVICE MASTS DYKEM <br /> 2 P 11 P 10 2 ATTACHED TO PORTABLE ROOF STRUCTURE.INSTALL BRACING <br /> E71 I �'�'- I E71 ANCHORS BELOW(NOT THROUGH)PORTABLE ROOFING <br /> SHINGLES TO ENSURE WATER PROOFING OF ROOF IS ARCHITECTURE + DESIGN <br /> D POSE PROPOSE P4 MAINTAINED. O <br /> 3. EXPOSED CONDUIT ON EXTERIOR OF BUILDINGS BELOW+10'-0" <br /> RTABLE RTA B L EXISTIN CONCEALED WITHIN SKIRTS ACE SHALL BE ALLOWEAFG SHALL BE RIGID METALLIC CONDUIT,PVC D <br /> I I <br /> DE <br /> O RTA B 4 OUWHETING AS DINDICATED,WALLSEAL PENETRATIONS WITH A ARE PENETRATED TO PIPPROVED <br /> FIRE/WEATHER PROOFING MATERIALS. <br /> 5. EXISTING FIRE ALARM PANEL IS AN EDWARDS EST2 MODEL. <br /> 2 <br /> _ 6. FIRE ALARM DRAWINGS HAVE BEEN SUBMITTED TO AHJ FOR 1201 third avenue,suite 600,seattle,wa 98101 <br /> ----- - - - REVIEW AND APPROVAL BASED ON DEVICE LAYOUTS SHOWN ON <br /> -- THESE DRAWINGS.CONTRACTOR IS RESPONSIBLE FOR 206.448.3376•206.448.4450 • hargis.biz <br /> 2 PROVIDING COMPLETE FIRE ALARM SYSTEM INCLUDING ANY <br /> SEPARATE PERMIT ADDITIONAL DEVICES REQUIRED BASED ON ONGOING REVIEW REGISTRATION STAMPS, <br /> TYPICAL OF GREY/ C AND PENDING APPROVAL.COORDINATE FIRE ALARM WORK WITH <br /> LIGHTENED LINE Vl CONVERGINT FIRE AND SECURITY.POINT OF CONTACT IS:CURTIS <br /> WEIGHT AREAS P/'� NASATKA,425-902-2517,CURTIS.NASATKA@CONVERGI NT.COM e5/2/2024 <br /> EX T ING 3 7. PVC CONDUIT SHALL BE ALLOWED FOR ROUTING CONCEALED IN <br /> EXISTIN PORTABLE CRAWL SPACE.O TABLE il <br /> C ORTAB FLAG NOTES <br /> ! I PROVIDE CONDUIT UP FROM PANEL TO TOP OF POLE TO <br /> FACILITATE AERIAL ROUTING AS INDICATED. PROVIDE Emerson ES 2024 <br /> WEATHERHEAD AND BRACING REQUIRED.PROVIDE ADDITIONAL <br /> ANCHORS AND GUY WIRE ATTACHMENTS AT TOP OF WOOD POLE Portable 11 <br /> TO ACCOMMODATE TENSION FORCES OF AERIAL CONDUCTORS. <br /> NEW 40 DIRECT BURY UTILITY POLE,ALIGN �>NEW 40'DIRECT BURY D�> PROVIDE QUADPLEX AERIAL.ROUTE ON MESSENGER WIRE.SEE FOR WITH WEST SIDE OF UTILITY POLE SEE E1.3 ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION. <br /> PORTABLE P5 ! FOR ASSOCIATED LOW PROVIDE SUPPORT MAST AND ASSOCIATED ACCESSORIES TO <br /> VOLTAGE PATHWAYS MAINTAINS+TMINIMUM ABOVE PORTABLE BUILDING ROOFS. Everett Public <br /> PROVIDE GUYING/BRACING FOR PORTABLE SERVICE MASTS SChOOIS <br /> MULTIPLE PORTABLE -- - -- - - - - - - - - - - -- "" "- -- - - -- - - _ -- -- - -- - - - -- - - - - _ - - - _ ATTACHED TO PORTABLE ROOF STRUCTURE.INSTALL BRACING <br /> FEEDERS.SEE ONE-LINE ANCHORS BELOW(NOT THROUGH)PORTABLE ROOFING <br /> 36"MIN 2 SHINGLES TO ENSURE WATER PROOFING OF ROOF IS AT <br /> MAINTAINED. <br /> O PORTABLES P2,,P3 P4470 <br /> PROVIDE SPLICE TO QUADPLEX AERIAL CONDUCTORS AND 8702 7th Ave SE <br /> PROVIDE NEW SERVICE ENTRANCE CONDUCTORS TO Everett, WA 98208 <br /> (E)XFMR'T-XFMR' 6 (E)PULL BOX ELECTRICAL PANEL AT WEATHERHEAD.PROVIDE GUYING/ <br /> (E)ECB'D-TDP' BRACING FOR PORTABLE SERVICE MASTS ATTACHED TO <br /> B _(E)DISTRIBUTION FPORTABLE ROOF STRUCTURE.INSTALL BRACING ANCHORS ELECTRICAL PERMIT SET <br /> PANEL'DP' BELOW(NOT THROUGH)PORTABLE ROOFING SHINGLES TO 05/02/2024 <br /> T ENSURE WATER PROOFING OF ROOF IS MAINTAINED. <br /> This drawing is. <br /> PROVIDE PULL BOX ON EXTERIOR OF PORTABLE BUILDING. 1.Copyright 2023 Dykeri Inc. <br /> B (E)FENCED PROVIDE CONDUITS WITH WEATHERHEAD AND MAST TO 2.The Architect's Instrument of Professional Service. <br /> 3.For use on this project only.Obtain Architect's B <br /> ENCLOSURE MAINTAIN NEC CLEARANCES ABOVE ROOF LINE.PROVIDE AERIAL written permission for any other use or reproduction. <br /> EXISTING SUPPORT PATHWAY,PROVIDE COMPLETE SUPPORT ASSEMBLY <br /> INCLUDING BUT NOT LIMITED TO MESSENGER,GUY WIRES, PROJECT <br /> 2 ELECTRICAL DISTRIBUTION ENLARGED DEMO PLAN ANCHORS,THROUGH-BOLTS,SADDLE WASHERS,THIMBLE-EYE <br /> E1.2 SCALE:NONE O RTA B L E BOLTS/NUTS,MAST ATTACHMENT CLAMPS,AUTOMATIC LOCKING <br /> CLEVIS,AND MISCELLANEOUS HARDWARE.SEE DETAIL 2,SHEET 2024-010 <br /> 2 3 E7.1 FOR ADDITIONAL INFORMATION. <br /> EXISTING UTILITY POLE E1.2 <br /> PROVIDE DIRECT BURY WOOD POLE TO FACILITATE OVERHEAD <br /> (E)FENCED ENCLOSURE --- ROUTING TO PORTABLES.PROVIDE POLE WITH HEIGHT AND MARK DATE DESCRIPTION <br /> MASTS TO ACCOMMODATE MINIMUM ELEVATION REQUIRED TO —.— <br /> MAINTAIN MINIMUM NEC OVERHEAD CLEARANCE FROM GRADE <br /> - - -. AND ROOFS.PROVIDE ANCHORS AND GUY WIRE ATTACHMENTS <br /> RMC CONDUIT AT TOP OF WOOD POLE FOR INTERMEDIATE SUPPORT OF NEW <br /> ROUTED ON AND %—_ __ AERIAL CONDUCTORS. <br /> SECURED TO 36"MIN <br /> PAVEMENT (E)OFCI DISCONNECT EXISTING FEEDER CONNECTION FOR PORTABLES <br /> DISTRIBUTION 2,3,4 FROM EXISTING ENCLOSED BREAKER.EXISTING PORTABLE <br /> PANEL'DP2' FEED SHALL REMAIN AND BE RECONNECTED TO NEW <br /> 7 e DISTRIBUTION PANEL.DEMOLISH EXISTING FEEDER FROM T-DP <br /> TO ENCLOSED BREAKER.SEE ONE-LINE DIAGRAMS FOR PROJECT <br /> (E)XFMR'T-XFMR' (E)PULL BOX ADDITIONAL INFORMATION AND REQUIREMENTS. <br /> (E)ECB'D-TDP' EXISTING PRINCIPAL IN AGCHARGE:: I BI <br /> B PA DISTRIBUTION DISTRIBUTION PANEL'DP2'HAS BEEN PROCURED BY THE OWNER PROJECT MANAGER: JH,DB <br /> PANEL'DP' PROJECT ARCHITECT: <br /> T O RTA B L T FACILITATE LEAD TIMES INSTALL EXISTING OWNER <br /> FENCED <br /> U JOB CAPTAIN: <br /> FURNISHED DISTRIBUTION PANEL. <br /> g <br /> A � e� PROVIDE UNISTRUT MEMBERS AND ACCESSORIES TO EXTEND A <br /> ENCLOSURE EXISTING UNISTRUT SUPPORT ASSEMBLY TO ACOMMODATE NEW ELECTRICAL PARTIAL <br /> DISTRIBUTION PANEL.INSTALL DISTRIBUTION PANEL AND MAKE SITE PLAN <br /> CONNECTIONS TO NEW AND EXISTING DISTRIBUTION.SEE <br /> 3 ELECTRICAL DISTRIBUTION ENLARGED PLAN ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION AND <br /> E1.z SCALE:1"=10'-0" REQUIREMENTS. <br /> DRAWING <br /> Q\ , ELECTRICAL PARTIAL SITE PLAN <br /> E12 SCALE:1"=IU-0" <br /> 2 3 4 5 <br />