Permit
E2405-012
Year
2024
Notes
ELECT FOR ADDITION OF SINGLE CLASSROOM PORTABLE #11 BUILDING
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 3 <br /> 4 5 <br /> SHEET NOTES <br /> 1. PROVIDE DEDICATED J-HOOK SUPPORT FOR EACH SYSTEM AT 4'-0" <br /> INTERVALS.J-HOOKS SHALL BE SUPPORTED BY DEDICATED <br /> SEPARATE PERMIT HANGERS/RODS ATTACHED TO STRUCTURE. , <br /> TYPICAL OF GREY/ <br /> LIGHTENED LINE 2. SEE SHEET E1.1 AND E1.3 FOR PULL BOX AND PORTABLE TO <br /> WEIGHT AREAS PORTABLE PATHWAY REQUIREMENTS. ARCHITECTURE , <br /> DESIGN <br /> 3. SEE SHEET E1.1 FOR LOW-VOLTAGE SYSTEMS PANELS/HEADEND <br /> LOCATIONS. D <br /> 4. PORTABLES HAVE 3/4"C FROM CRAWL SPACE TO BACK BOX AND a <br /> _ 3/4"C TO CEILING SPACE AT EACH ROUGH-IN LOCATION. <br /> AA <br /> (E)PANEL'P11 5. SEE SHEET E7.2 FOR TELECOMMUNICATIONS DEVICE INSTALLATION <br /> AND FACEPLATE DETAILS. <br /> �I i—(E)PANEL'P10'a <br /> (N)PATHWAY,SEE �,�,--� r------------- ---------------- P10-8 SITE PLAN FOR ; ° FIRE ALARM NOTES <br /> REQUIREMENTS] i ) 1201 third a venue,suite 600,seattle,wa 98101 <br /> + FIRE ALARM <br /> m ( ¢ 1. ROUTE NEW FIRE ALARM CONDUCTORS TO EXTEND EXISTING 206.448.3376•206.448.4450 hargis.biz <br /> ]—— <br /> J NAC PANEL FIRE ALARM SYSTEM TO NEW PORTABLES.SEE SITE PLAN AND <br /> ap" <br /> COORDINATE WITH FIRE ALARM VENDOR FINAL SHOP DRAWINGS <br /> P11 <br /> FOR ADDITIONAL INFORMATION. •( P10 2. EXISTING FIRE ALARM PANEL IS A EDWARDS EST2.SEE SITE PLAN <br /> + FOR LOCATION. IS j <br /> 1° --- 3. FIRE ALARM DRAWINGS HAVE BEEN SUBMITTED TO AHJ FOR <br /> g REVIEW AND APPROVAL BASED ON DEVICE LAYOUTS SHO <br /> WN ON <br /> — THESE DRAWINGS.CONTRACTOR PROVIDING COMPLE E IRE ALAARM SYST M IINICLUDING ANY <br /> � H r, <br /> LIQJ 1'�yy1 H ADDITIONAL DEVICES REQUIRED BASED ON ONGOING REVIEW <br /> C AP I AP Lg AND PENDING APPROVAL.COORDINATE FIRE ALARM WORK WITH <br /> /'f [(3 CONVERGINT FIRE AND SECURITY.POINT OF CONTACT IS:CURTIS 5/2/2024 <br /> NASATKA,425-902-2517,CURTIS.NASATKA@CONVERGINT.COM C <br /> PROJECT • <br /> � <br /> 4. PROVIDE NEW FIRE ALARM DEVICES AT L� OCATIONS SHOWN. <br /> CONDUIT AND BACK BOXES FOR WALL MOUNTED DEVICES Emerson ES 2024 <br /> INDICATED ARE EXISTING. Portable 11 <br /> a 4 5. PROVIDE PROGRAMMING AND COMPONENTS REQUIRED TO <br /> UPGRADE EXISTING PANEL TO SERVE RELOCATED EXISTING AND FOR <br /> ADDITIONAL NEW PORTABLES. <br /> 6. OPEN CABLING ABOVE CEILINGS IS ACCEPTABLE. Everett Public <br /> —� - - _- Schools <br /> �I 12WP FLAG NOTES AT <br /> -� ROUTE CABLING IN CEILING SPACE/CRAWL SPACE,SEE NOTE 1. <br /> 8702 7th Ave SE <br /> (N)PATHWAY,SEE SITE PLAN FOR PROVIDE RECESSED ROUGH-IN AND FIRE ALARM DEVICE AS Everett, WA 98208 REQUIREMENTS INDICATED IN CEILING TILE BELOW CEILING. <br /> PROVIDE FIRE ALARM DEVICE IN CEILING SPACE AS INDICATED, ELECTRICAL PERMIT SET <br /> EXISTING INTRUSION DETECTION DEVICE,PROVIDE CONNECTION 05/02/2024 <br /> TO PORTABLE SECURITY PANEL. This drawing is: <br /> B 1.Copyright 2023 Dykeman,Inc. <br /> EXISTING SURFACE MOUNT INTERCOM SPEAKER,PROVIDE 2.The Architect's Instrument of Professional Service. <br /> CONNECTION TO INTERCOM CROSS CONNECT BLOCKS/ 3.For use on this project only.Obtain Architect's B <br /> LOW-VOLTAGE FLOOR PLANS written permiss <br /> 1 <br /> ion for any other use or reproduction. <br /> N Ea+ SCALE.1/4 -1-0 HEADEND. <br /> TRANSITION CABLING FROM PORTABLE CRAWL SPACE TO PROJECT NUMBER: <br /> PORTABLE CEILING SPACE THROUGH(E)ROUGH-IN LOCATION. 2024-0 1 0 <br /> PROVIDE INTRUSION DETECTION DEVICE,PROVIDE CONNECTION <br /> TO PORTABLE SECURITY PANEL. <br /> mitaTA1.11010 <br /> e� PROVIDE NEW PANELBOARD PHENOLIC NAMEPLATE.SEE DETAIL MARK DATE DESCRIPTION <br /> 4 ON SHEET E7.1 AND ELECTRICAL IDENTIFICATION <br /> SPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION. <br /> LOCATE TOP OF NAC PANEL FLUSH WITH CEILING SUCH THAT FA <br /> CABLING AND HOMERUN MC CABLE CAN REMAIN CONCEALED IN <br /> ACCESSIBLE CEILING SPACE. <br /> +o PROVIDE REMOTE MONITORING MODULE FOR HEAT DETECTORS <br /> ABOVE ACCESSIBLE CEILING.COORDINATE INSTALLATION WITH <br /> FIRE ALARM SHOP DRAWINGS PRIOR TO ROUGH-IN, PROJECT TEAM: <br /> PRINCIPAL IN CHARGE:I BI <br /> PROJECT MANAGER. I JH DB <br /> _PROJECT ARCHITECT: I <br /> JOB CAPTAIN: <br /> A <br /> DRAWING <br /> LOW-VOLTAGE FLOOR A <br /> PLANS <br /> DRAWING NUMBER: <br /> 3 4 <br /> 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.