Laserfiche WebLink
EI <br /> NEUDORFER <br /> n:t e g ra ENGINEERS <br /> AN integra COMPANY <br /> TERMS AND ABBREVIATIONS <br /> AC or ACU Air Conditioner or Air Conditioning Unit HEPA High Efficiency Particulate Absorbing <br /> AH or AHU Air Handler or Air Handling Unit HP Horsepower <br /> ACH Air Changes per Hour HVAC Heating Ventilation and Air Conditioning <br /> Airfoil Instrument used to measure air velocity in HWS Heating Water Supply <br /> feet per minute. HWR Heating Water Return <br /> AVG Average HX Heat Exchanger <br /> BHP Brake Horsepower HZ Hertz, cycle per second <br /> CAV Constant Air Volume in.w.g. inches of water gauge <br /> CBV Calibrated Balancing Valve(Circuit Setter) Kfactor Correction factor to the free area need to <br /> CC Cooling Coil calculate CFM. <br /> CD Ceiling Diffuser KW Kilowatts <br /> CFM Cubic Feet per Minute LAT Leaving Air Temperature <br /> CH Chiller LWG Low Wall Grille <br /> CHWS Chilled Water Supply LWR Low Wall Register <br /> CHWR Chilled Water Return LWT Leaving Water Temperature <br /> CP Circulating Pump MAU Make-up Air Handling Unit <br /> CR Ceiling Register MBH 1,000 BTUH <br /> CRAC Computer Room Air Conditioner OSA Outside Air <br /> CRU Computer Room Unit OBD Opposed Blade Damper <br /> CT Cooling Tower OP Pressure Drop <br /> CU Condensing Unit PH Phase <br /> CUH Cabinet Unit Heater Pitot Tube Instrument used to measure air velocity <br /> CWS Condenser Water Supply PSI Pounds per Square Inch <br /> CWR Condenser Water Return RA Return Air <br /> DAT Discharge Air Temperature RAT Return Air Temperature <br /> DB Dry Bulb RF Return Fan <br /> DCV Demand Control Ventilation RH Relative Humidity <br /> DDC Direct Digital Controls RHC Reheat Coil <br /> EA Exhaust Air RPM Revolutions per Minute <br /> EAT Entering Air Temperature RTU Roof Top Unit <br /> Economizer Controls and components that allow an air SA Supply Air <br /> handler to logically utilize outdoor air for SAT Supply Air Temperature <br /> cooling and demand control ventilation. S.F. Service Factor <br /> EF Exhaust Fan SF Supply Fan <br /> EG Exhaust Grille SFD Smoke/Fire Damper <br /> EMCS Emergency Management Control System SP Static Pressure <br /> ERU Energy Recovery Unit sq.ft. square feet <br /> E.S.P. External Static Pressure SWG Sidewall Grille <br /> HRC Heat Recovery Coil SWR Side Wall Register <br /> EWT Entering Water Temperature TAB Test,Adjust, and Balance <br /> FCU Fan Coil Unit TDH Pressure difference across the entering <br /> FD Fire Damper and leaving side of a pump. <br /> FPB Fan Powered Box TSP Total Static Pressure <br /> FSD Fire Smoke Damper UH Unit Heater <br /> FLA Full Load Amperage UV Unit Ventilator <br /> Flow Hood Instrument used to measure airflow in cubic VAV Variable Air Volume, box that contains a <br /> feet per minute. motorized damper that modulates airflow <br /> FHT Fume Hood Test VD Volume Damper <br /> FPB Fan Powered Box VFD Variable Frequency Drive <br /> FPM Feet per Minute Velgrid Instrument used to measure air velocity in <br /> FIR Field Report feet per minute <br /> FT Foot, Feet VVT Variable Volume Terminal <br /> FTU Fan Terminal Unit W.C. or WC Water Column <br /> GPM Gallons per Minute W.G.or WG Water Gauge <br /> HC Heating Coil WB Wet Bulb <br /> . _,- .- of 22 <br />