Laserfiche WebLink
• NEUDORFER <br /> i riteg ra ENGINEERS <br /> AN integra COMPANY <br /> INSTRUMENT CALIBRATIONS <br /> AIRDATA MULTIMETER CERTIFICATE OF RECALIBRATION <br /> Customer ID: 003697 SIN: M07575 <br /> Customer: NEUDORFER ENGINEERS,INC. City: SEATTLE State: WA <br /> As-Received Model#: ADM-860C Converted to Model M Order#: R250463 <br /> PO#: Customer Eqpt ID#: Calibration Due Date: <br /> This instrument has been calibrated using Calibration Standards which are traceable to NIST(National Institute of Standards and Technology). Test accuracy ratio <br /> is 4:1 for pressures and temperature. Quality Assurance Program and calibration procedures meet the requirements for ANSI/NCSL Z540-1,ISO 17025,MIL-STD <br /> 45662A and manufacturer's specifications. Calibration accuracy is certified when meters are used with properly functioning accessories only. All Uncertainties are <br /> expressed in expanded terms(twice the calculated uncertainty). This report shall not be reproduced,except in full,without the written approval of Shortridge <br /> Instruments,Inc. Results relate only to the item calibrated. For limitations on use,see Shortridge Instruments, Inc.Instruction Manual for the use of AirData <br /> Multimeters. Procedure used: Procedure for Differential Pressure, Absolute Pressure and Temperature Recalibration of AirData Multimeters SIP-CP02 <br /> Revision:30 Dated:04/04/16 <br /> Calibration Technician(s): L7 kkd,,L t� A• S41cam"M" 1 <br /> �1 Calibration Date:O�12.1 1.L.5 <br /> Calibration Approved by:_ alo � tIi Title: QA ftYv- Date: o3 iml zo?yj <br /> As-Received By LB. s Prvct e. I Tgst By A Jciwn'.I�O Test By <br /> Date 6311'LI2025 Rh'LL % Date 03>h 12oz5 Rh o% Da Rh % <br /> Ambient Temperature 14 °F Ambient Temperature 72 °F AmbientTampc?atu F <br /> Barometric Pressure 2t3.G3 in Hg Barometric Pressure ZA.3G in Hg Barometric Pressure -'�1n Hg <br /> All within spec YES NO NA All within spec NO All within spec YES NO <br /> ABSOLUTE PRESSURE TEST(in Hg) <br /> TEST METER TOLERANCE_±2.0/°±.1 in Hg AS-RECEIVED TEST WITHIN SPEC YES NO kE2ESee N <br /> Pressure Standard:Heise#02-R SIN:41741/42451 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#12A-R SIN:45605/48491 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#04-R SIN:41743/42453 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#14-R SIN:4 341 2/45 043-3 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#06-R SIN:41742142452-1 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#16-R SIN:4 341 3/45 044 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#08-R SIN:42186/43328 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#18-R SIN:44581/46845-2 As-Rcvd est ) Test 3 <br /> Pressure Standard:Heise#10-R SIN:42203/43352 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#20-R SIN:44582/46847 As-Rcvd Test 2 Test 3 <br /> Approx Set Pt Standard Test Meter %Diff Standard Test Meter %Diff Standard Test Meter %Diff <br /> 14.0 t2- <br /> ILI// A. <br /> 28.4 b Z 40.0 �O.I •0-7 <br /> DIFFERENTIAL PRESSURE TEST(in wc) <br /> TEST METER TOLERANCE_±2.0%:0.001 in we AS-RECEIVED TEST WITHIN SPEC YES NO See Not <br /> Pressure Standard:Heise#01-L SIN:41739/42449 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#11-L SIN:4 31 6 5/44 5 51-1 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#01-R SIN:41739/42446 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#11-R SIN:4 31 6 5/44 7 30 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#02-L SIN:41741/42454 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#12A-L SIN:45605/48490-1 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#03A-L SIN:45570148461 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#13-L SIN:43415/45041 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#03A-R SIN:45570/48460 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#13-R S/N:43415/45039 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#04-L SIN:41743/42456 As-Rcvd Test 2 Test 3 ,Pressure Standard:Heise#14-L SIN:43412/45045 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#05-L SIN:41740142450 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#15-L SIN:43416145042 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#05-R SIN:41740/42447 As-Rcvd Test Test Pressure Standard:Heise#15-R SIN:43416/45040-1 As-Rcvd Test Test <br /> Pressure Standard:Heise#06-L SIN:41742/42455 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#16-L SIN:43413145046 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#07-L SIN:42185/42186 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#17-L SIN:44579/46842 As-Rcvd <es Test 3 <br /> Pressure Standard:Heise#07-R SIN:42185/43326 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#17-R SIN:44579/46841 As-Rcvd es Test 3 <br /> Pressure Standard:Heise#08-L SIN:42186/43329 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#18-L SIN:44581/46846 As-Rcvd est Test 3 <br /> Pressure Standard:Heise#09-L SIN:42202143351 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#19-L SIN:44580/46844 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#09-R SIN:42202/43350 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#19-R S/N:44580/46843 As-Rcvd Test 2 Test 3 <br /> Pressure Standard:Heise#10-L SIN:42203/43353 As-Rcvd Test 2 Test 3 Pressure Standard:Heise#20-L SIN:44582/46848 As-Rcvd Test 2 Test 3 <br /> Approx Set Pt Standard Test Meter %Diff Standard Test Meter %Diff Standard Test Meter %Diff <br /> 0.0500 -o Io .C5 a •00 <br /> 0.1250 -VIS6 12 5 b .00 <br /> 0.2250 1151 Z2 5n -•Ot-I <br /> 1.000 1.005 I.00-7 --Lo <br /> 2.000 t,11A 2.cc Z_o t 3 • 3 5 <br /> 3.600 3.607 3.617 <br /> .617 • 28 <br /> 4.400 2 S2 <br /> 27.00 -0 27• to 3 <br /> 50.00 jo• 6 L19• yLI `1Z <br /> Overange NA NA NA V-- NA NA NA <br /> Shortridge Instruments,Inc. <br /> 7855 East Redfield Road Scottsdale,Arizona 85260 <br /> (480)991-6744 • Fax(480)443-1267 • www.shortridge.com <br /> ADM Recalibration Rev 54-07-22-24 1 of 2 07=024 <br /> )f 22 <br />