• NEUDORFER <br /> i riteg ra ENGINEERS <br /> AN integra COMPANY <br /> INSTRUMENT CALIBRATIONS <br /> Shortridge Instruments, Inc. AirData Multimeter Calibration Equipment <br /> Customer Order Number, Meter Serial Number,and Test Type are referenced on page 1 <br /> LOW VELOCITY EQUIVALENT CONFIRMATION STANDARDS <br /> Vel Eqv Transfer Standard SIN:M02009 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:08/30/24 Due Date:08/2025 <br /> Vel Eqv Transfer Standard SIN:M02903 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:12/19/24 Due Date:12/2025 <br /> Vel Eqv Transfer Standard SIN:M10839 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:10/25/24 Due Date:10/2025 <br /> Vel Eqv Transfer Standard SIN:M10840 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:10/29/24 Due Date:1012025 <br /> Vel Eqv Transfer Standard SIN:M10897 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:01/22/25 Due Date:01/2026 <br /> Val Eqv Transfer Standard SIN:M10901 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,inc. Calibration Date:12/19/24 Due Date:12/2025 <br /> Vel Eqv Transfer Standard SIN:M13492 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,inc. Calibration Date:09/05/24 Due Date:08/2025 <br /> Vel Eqv Transfer Standard SIN:M19325 Model ADM-870C Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:06/06/24 Due Date:06/2025 <br /> Rated Accuracy: Velocity t 1.5%t 3.5 fpm Range:100-5000 fpm Resolution:0.1 Uncertainty:<5.00 fpm at 100 fpm;<7.50 fpm at 600 fpm <br /> TEMPERATURE STANDARDS <br /> RTD Simulator SIN:249 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:04/11/24 Due Date:04/2028 <br /> RTD Simulator SIN:250 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:04/11/24 Due Date:04/2028 <br /> RTD Simulator SIN:253 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:04111/24 Due Date:0412028 <br /> RTD Simulator SIN:254 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:08/20/24 Due Date:08/2028 <br /> RTD Simulator SIN:256 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:08/20/24 Due Date:08/2028 <br /> RTD Simulator SIN:257 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:08120/24 Due Date:08/2028 <br /> RTD Simulator SIN:292 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:01115/24 Due Date:01/2028 <br /> RTD Simulator SIN:293 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:01/15/24 Due Date:0112028 <br /> RTD Simulator SIN:294 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:01115/24 Due Date:01/2028 <br /> RTD Simulator SIN:313 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:03/25/22 Due Date:03/2026 <br /> RTD Simulator SIN:314 Model RTD-1 DOOI500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:03/25/22 Due Date:03/2026 <br /> RTD Simulator SIN:315 Model RTD-10001500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:03/25/22 Due Date:0312026 <br /> RTD Simulator SIN:316 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:06/06/22 Due Date:05/2026 <br /> RTD Simulator SIN:317 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:05/23/22 Due Date:05/2026 <br /> RTD Simulator SIN:318 Model RTD-1000/500 Mfgd by General Resistance Calibrated by IET Labs Calibration Date:05/23/22 Due Date:05/2026 <br /> Rated Accuracy:0.025%of setting Range:100.00 0 to 11111.10 0 Resolution:0.01 0 Uncertainty:s 32 ppm <br /> Thermometer#1 SIN 8A089/Thermistor SIN A410660 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date:04/09/24 Due Date:04/2026 <br /> Thermometer#2 SIN 8B104/Thermistor SIN 871507 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date:12/19/24 Due Date:1212026 <br /> Thermometer#5 SIN B11780/Thermistor SIN B10505 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date:06/27/24 Due Date:06/2026 <br /> Thermometer#6 SIN B11782IThermistor SIN B10509 Model 1504/5610 Mfgd by Hart Scientific Calibrated by Fluke Calibration Date:09/21/24 Due Date:09/2026 <br /> Thermometer#7 SIN B49938/Thermistor SIN B482202 Model 1504/5610 Mfgd and Calibrated by Fluke Calibration Date:02/05/24 Due Date:02/2026 <br /> Rated Accuracy(combined):0.03240 F Range:32°F to 176°F Resolution:0.001-F Combined Uncertainty with Baths: s 0.040'F <br /> Temp Transfer Standard SIN M00136 Model ADM-870 Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:10/25/24 Due Date:10/2025 <br /> Temp Transfer Standard SIN M96100 Model ADM-870 Mfgd&Calibrated by Shortridge Instruments,Inc. Calibration Date:03/21/24 Due Date:03/2025 <br /> Rated Accuracy:0.030 F Range:33'F to 158'F Resolution:0.01-F Uncertainty:<0.023°F <br /> Total combined Uncertainty for MultiTemp and TemProbe testing:s 0.046'F <br /> This form must remain with the Certificate of Calibration corresponding to the Customer Order Number and Meter Serial Number <br /> referenced on page 1. <br /> Shortridge Instruments, Inc. <br /> 7855 East Redfield Road Scottsdale,Arizona 85260 <br /> (480)991-6744 • Fax(480)443-1267 • www.shortridge.com <br /> ADM Cal Stnds Rev 20 07-22-24 2 of 2 02/03/2025 )f 22 <br />