Laserfiche WebLink
J A I B I C I 0 I E I F I G I H I i I K L <br /> AHU AHU AHU AHU �� AHU AHU AHU AHU Z5) <br /> AHU <br /> C:2�) 12 11 10 9 a 7 s s a 147 3 CONSTRUCTION NOTES <br /> 1"0(TYP) 10 - INSTALL AIR HANDLER IN ACCORDANCE WITH MFR'S REQUIREMENTS AND DETAIL"A"ONa;� Py _ _ _ _ _ _SLOPE 1% _ _ <br /> _ 1"0 _ _ 1 1/4"0 1 O ALL CONDENSATE PIPING IS SCHEDULE 40 PVC. INSTALL CHECK VALVE AS SHOWN. SEE <br /> 1"Ol <br /> 5 O PVC PIPING CONSTRUCTION SPECIFICATION ON SHEET M0.0. s'a <br /> — 9 <br /> 9 PHOTO-1 1 1/4 0 1. .�2� <br /> (E)EECTRICALSWITCH GEAR 'VIEWPHO DI 2 CONNECT MAIN DRAIN PIPE TO INLET OF PUMP AS REQUIRED. PUMP ELEVATION AND LEVEL <br /> M1 A VIEW DIRECTION 2 SHALL BE SAME AS AIR HANDLERS. ADAPT TO INLET OF PUMP AS REQUIRED. PROVIDE <br /> VIEW DIRECTIONM1.0 M2.0 8 F CHECK VALVE AND SHUT OFF VALVE AT INLET OF PUMP ON PIPING. <br /> I �_y <br /> 2 r AHU O4 INSTALL P1(CONDENSATE PUMP)PER NOTE#3,AND SECURE/SEISMIC BRACE PER MFR. <br /> 1 REQUIREMENTS AND AS REQUIRED. SEE EQUIPMENT SCHEDULE THIS DRAWING. 8 <br /> O O5 INSTALL VERTICAL1-1/8"PIPE UP THRU ROOF. TERMINATE ON ROOF AND ELBOW TOWARD 2 „ <br /> -- _ 19, <br /> EXISTING ROOF DRAIN. SUPPORT VERTICAL PIPING FROM WALL USING UNI-STRUT,AND 3 a m <br /> PIPE CLIPS(B-LINE)AS REQUIRED. SEISMIC BRACE IN AT LEAST TWO PLACES 4'ABOVE l a o5 <br /> tp OUTLET,AND 5'BELOW ROOF. WEATHER SEAL PENETRATION AS REQUIRED. =3 <br /> LOW ROOF EDGE a <br /> O6 PROVIDE(TYP-ALL UNITS)"P"TRAP AS REQUIRED AT CONNECTION. <br /> y-' O INSTALL FILTER BOX WITH MERV 13 FILTERS AS REQUIRED. SEE DETAIL"D"ON DRAWING 3 <br /> 3 M2.0 L <br /> n AV - B O SUPPORT ALL REFRIGERANT LINES IN ACCORDANCE WITH SMACNA STANDARDS AND <br /> - - - - - - REFRIGERANT LINE CODE ON 2021 IMC SECTION 1107 AS REQUIRED. SEE DETAIL"C". <br /> SEISMIC BRACE EVERY 20'O.C. <br /> _ NORTH <br /> MANUFACTURING - 2nd FLOOR ENCLOSURES - HVAC PLAN O INSTALL REFRIGERANT PIPING UP THRU ROOF. AT <br /> PENETRATION. CONTINUE OCU-1 WHERE AHUPR03,4 WEATHER&8C0 NECTSTON AHUF5,6,9, <br /> SCALE:3/16"—1'-0" 10,11&12 CONNECTS TO CU-2. (SEE PARTIAL ROOF PLAN,THIS DRAWING.) <br /> 10 INSTALL CONDENSERS ON ROOF PER MFR'S REQUIREMENTS IN LOCATION(S)SHOWN. 4 <br /> 4 14.7 <br /> ��• SEISMIC BRACE PER LOCAL CODES AS REQUIRED. <br /> g � <br /> 11 USE METAL TABS TO SECURE CONDENSER TO ROOF(4-PLCS)FOR BOLTS LAGGED INTO <br /> 1 A ROOF PER MFR.INSTRUCTIONS. WEATHER SEAL AS REQUIRED. <br /> (TYP-10) <br /> 12 PROVIDE UNI-STRUT FOR REFRIGERANT PIPING SUPPORT ON ROOF SPACED NOT TO <br /> I EXCEED 10'-0"O.C. LAG UNI-STRUT TO ROOF AND WEATHER SEAL. USE PIPE CLIPS TO <br /> I" SECURE PIPING ONTO UNI-STRUT AS REQUIRED.ALL REFRIGERANT PIPING SHALL BE <br /> PROTECTED FROM DAMAGE AS REQUIRED AT VARIOUS CROSS OVER AREAS AS <br /> CU CU NECESSARY. <br /> _ (E)HIGH ROOF AREA 5 <br /> 5 `,, 10 2 10 1 13 INSTALL/CONSTRUCT PIPING SETS AS REQUIRED ON ROOF IN ACCORDANCE WITH NOTE <br /> T' #12 AS REQUIRED. ROUTE ON ROOF,THE MOST DIRECT WAY FROM ROOF PENETRATION AT <br /> WEATHER BOOT. <br /> NEW (E)LOW ROOF AREA <br /> i ENCLOSURE <br /> 11 (TYP)I 14 ALL ROUTING ON ROOF SHALL FOLLOW GUIDELINES OF 2012 IMC CODES,SECTION 1107 AS <br /> E— 12 I REQUIRED. CONNECT TO MULTI-PORT AREAS AT CONDENSERS PER NOTE#9 AS REQUIRED. 03 <br /> to coIII (TYP)I es c (n ONO <br /> as <br /> ® ❑ � .� ao <br /> 6 0 I��L 13 14 I 6 co <br /> / 0 > <br /> B <br /> LU <br /> (E)SKYLIGHT(REF) B <br /> (TYP-3) NORTH N <br /> PHOTO 1 - (E) ENCLOSURES PARTIAL ROOF PLAN <br /> 7 PERSPECTIVE VIEW NOT SHOWN TO SCALE FOR CLARITY 7 <br /> REMOVE ALL(E)CABINET <br /> (D IOUNTED AC UNITS <br /> 1/2"0 ROD MIN.SIZE. O <br /> .1. ¢ v <br /> CONFIRM SIZING WITH O MOISTURE SENSOR- <br /> MFR.REQUIREMENTS, q <br /> INTERLOCKED W/AHU MOTOR, 4 <br /> 8 _ _ (AHU-9 THRU 12 ONLY) FOR SHUT-OFF IN THE EVENT OF 8 F­ U <br /> MOISTURE/WATER DETECTION. z <br /> w w <br /> Do <br /> a <br /> I _ SEISMIC BRACE AS REQ'D&PER CODE. a (L Z U <br /> l PAN SUPPORT& LU o r z <br /> IIIIIIIII( - ®tea SEISMICPER SIDE AHU 6 14. Z <br /> 2 w U <br /> O <br /> « (REF) 1-5/8"x 1-5/8" U X U a <br /> UNISTRUT(OR A w 7 CIS <br /> EQUAL) - li.i 2 1, N & LU <br /> w <br /> 9 �— A B 9 F � Zc _ <br /> z � <br /> W w '' u' w <br /> _ > ga ¢ Q > <br /> CONDENSATE PUMP SCHEDULE �' " � � a <br /> UL <br /> — SHEET METAL CONDENSATE DRAIN PAN SPECIFIED ELECTRICAL <br /> NOTE: FABRICATE&CONSTRUCT SYMBOL MANUFACTURER AND FLOW SHUT-OFF DISCHARGE WEIGHT REMARKS <br /> PER IMC-2021 SECTION 307(TYP) SERIES NO. GPHIGPM HEAD FT SIZE DIA. HP VOLTSIPH LEIS REMARKS <br /> PHOTO 2 - (E) ENCLOSURES ELEVATION - DRAIN PAN LITTLE GIANT 1-ASS PUMP FOR SHALLOW PAN KEY PLAN n/� 1 .0 <br /> P-1 #550532 205/3.4 10 1/4" 1/150 230/1 3.75 (2"DEEP);OIL FILLED MOTOR ' <br /> 10 PERSPECTIVE VIEW NO SCALE NO SCALE 10 `/' <br /> o^ r 2^ <br /> Permit Set ABOVE LIINEIMEASURES AS NOTED <br /> A I B I C I D I E I F I G I H I J I K F <br />