My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 11:49:55 AM
Creation date
1/2/2026 11:49:09 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-078
Year
2024
Notes
BLDG 40-26 1ST FLR HVAC, Compressed Air, Vacuum and Water
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> 3 3.5 4 4.5 5 <br /> GENERAL NOTES <br /> MATCH LINE _ <br /> O SEE DRAWING 1 M21 <br /> N - - - EWC - - - - - - EWC <br /> wz o <br /> =10 o REFERENCE DRAWINGS <br /> I � w o <br /> N N <br /> n fl GRILLE 14'-6" AFF TYP 42x50 TUNNEL <br /> o �o G2:24%10" o <br /> GRILLE 6'-10° AFF SHEET NOTES <br /> TYP RG ROUTER ROOM 18x20 q MIC 7 (FD-8 BULK) PROVIDE DUCT MOUNTED SMOKE DETECTOR IN <br /> 101P3 2 HC 03g126 513 VERTICAL DUCT WITHIN 5'-O" OF FIRE SMOKE DAMPER. <br /> 4 I <br /> TYP 4 TO N J20x18 x <br /> 800 CFM 2 � ---' <br /> 20x10 20x14 FC I <br /> 17 � 16 GA. GALV. WIRE SCREE x <br /> 22x18� 22x18 12x10 8 POC T 50"0 SUPPLY / COVER FAN INTAKE W/ 1" MESH <br /> 2 x18 RS 20x10 2 x14 TOUC42"x 50SITION x AT <br /> 9F 12 AFF CONSTR�GT ON NOTES <br /> a <br /> Vv O Lp <br /> 20x14 UP LVDR 16/12 CUT OFF AT 1 A �� ESx16 DN �CAP OPEN DUCT WITH LIKE KIND MATERIAL. <br /> �< 80 DUST CD TYP 3C POC 101P4 50 �EXISTING AHU-25 SERVING ROOM TO HAVE REBALANCED <br /> B 1 300 CFM ST IR R4 A AIRFLOW AS INDICATED ON SHEET MOB. INCLUDE THE <br /> ASB 1 M26 M565 m 16/12 CUT OFF AT 14' A ° o o O REBALANCING OF AIRFLOW FOR DUCT RUNS ASSOCIATED <br /> WITH RHC-3 AND RHC-4. REFER TO SHEET MOH2 FOR <br /> � AIRFLOWS TO BE USED, PER REHEAT COIL SCHEDULE. <br /> 4 120 DUST FOR SEQUENCE OF� 16x12 EXHAUST DUCT P <br /> 6 OPERATION, SEE 1 TYP 24x12 UP 2 OWNER FURNISHED, CONTRACTOR INSTALLED DUST <br /> 1M26 M300 24x16 SUPPLY DUCT UP SEE AND FOR DETAIL LEMET E G C <br /> DUST TO HVAC 28 7iM26 M535 iM26 M535 <br /> COLLECTOR 4 CONNELLECTION DUCT TO DUST COLLECTOR24/16 CUT OFF AT 13' AFF PER MER'S INSTALLATION INSTRUCTIONS.ROUTENE ELEVATION THROUGH EXTERIORA WALL. SHEET 40-026-1A26 FOR FLASHING1M26 M565 BY GC. ESCUTCHEON FOR INTERIOR SIDE OFD-01 WALL P WITH SAME MATERIAL AS DUCT.DU U A 6- <br /> TERMINATE WITH FLANGED END FOR LATER CONNECTION BELOW CEILING. SUPPORT DUCTWORK WITH CABLE <br /> TO FUTURE FLEX DUCT DOWN TO FUTURE PANEL MOUNTING SYSTEM FROM STRUCTURE ABOVE. <br /> ROUTER. PROVIDE SLIDE GATE NEAR TERMINATION AND <br /> UTILIZE TO BALANCE ROOM AIR FLOW INTO DUCT AT ©PROVIDE DUCT MANUFACTURER'S CLFANOUT DOOR WITH <br /> 1,600 CFM. OPENING ON BOTH SIDES OF ELBOW FOR INSPECTION <br /> AND CLEANING. IN DUCTWORK LARGER THAN 10" DIA., <br /> ®TERMINATE WITH FLANGED END FOR FLEX DUCT ACCESS DOORS/OPENINGS EVERY 50 FT AND AFTER <br /> CONNECTION. PROVIDE SLIDE GATE NEAR FLANGED EVERY ELBOW (TURN) WILL BE ACCEPTABLE AS A <br /> END AND UTILIZE TO BALANCE AIRFLOW TO 1,600 CFM. MEANS OF SATISFYING NFPA REQUIREMENTS PER <br /> FLEX DUCT TO PANEL ROUTER BY VENDOR/SUPPLIER. 02/14/24 BOEING CONVERSATION WITH CITY OF EVERETT <br /> FIRE MARSHALL. <br /> T <br /> 5 9 11 <br /> 0.9 <br /> 1 <br /> B DG 4111025 <br /> PARTIAL FIRST FLOOR HVAC PLAN N <br /> SCALE:1/8"=1'-O" FINISH FLOOR EL 100'-0" N 1 1 M 10 11 M 1 1 1 1 M 12 1 1 M 13 1 1 M 14 M <br /> IT I <br /> o <br /> *� - � * o <br /> r1M <br /> 1M16 1M17 1M18 1M19 <br /> N.7 o <br /> 1 1 M21 11 M22 11 M23 11 M24 m <br /> P <br /> 1M25 M2 1 M 2 7 1M28— R <br /> FUTURE BLDG 40-027 <br /> * DENOTES PLANS <br /> BUILDING 40-026 NOT INCLUDED <br /> KEY PLAN IN THIS DWG. <br /> SET <br /> SCALE: NONE <br /> ��'Affiliated DCN-01, SCOPE CLAR. ADD. <br /> Engineers <br /> 580 R=-hePa,knBodIe d ISSUED FOR CONSTRUCTION 4' r ° 4' 8' ,r 16' 20' <br /> IAaelson,Wisconsin 53719 <br /> PROFESSIONAL STAMP&SIGNATURE APPLIES TO WORK Tel 608.238.2616 DESIGN BY AEI DATE 03.25.24 <br /> WITHIN THE CLOUDED REVISION AREAS ONLY AS INDICATED PrfeCl <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYM GATE <br /> ACCEPTABILITY R.ANDERSON 03KLU .25.24 PARTIAL FIRST FLOOR HVAC PLAN W88613600 03.25.24 <br /> RECORD DRAWING ISSUED TO OWNER FEW FPW 09.29.97 - RECORD DRAWING ISSUED TO OWNER 565973-02 AEI 07.31.09 qR THIS DESIGN AND/OR pHEROEDL 032524 s„EET SPECIFICATION IS APPROVEDR 777 ML DEMO VERIZON OFFICE J# 535442-84 JHB FB/BAO 10.20.04 D-01 737 NL-40-26 DP 26.02-DCN-01 SCOPE CLAR.ADD.W8861360 AEI B. FRIEDMAN 03.25.24 APPROVED BY DEPT. DATE TITLE 737 NORTH LINE - 40-26 TOWER RELOCATIONS DP 26.021 M26 <br /> D„EKEDA DEMO BURN LAB J#54684842 JM BOC 12.01.04 BUILDING 40-026 APPROVED JOB N0. COMP NO. <br /> B RECORD DRAWING CLEAN-UP J# 555672-04 DLR GROUP KAP 10.14.05 03/25/M41 B. FRIEDMAN 03.25.24 <br /> C BFF- ISSUE FOR CONSTRUCTION 565973_02 AEI 07.16.07 APPROVED MECHANICAL MASTER COL. P-R/3-5 EVERETT, WA DWG NO. 40-026-1M26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.