D W S 5 - WAREHOUSE RENOVATION PROJECT Additional Permits Are Required Permit so ARCHITECT
<br /> For This Project To Include: Site Address:
<br /> 6617 Aress: 6617 Associated Blvd
<br /> Plumbing Sprinkler Owner: EVERETT COMMERCE CENTER ILP LLC OF
<br /> App.Date: 8/15/2024
<br /> Mechanical Fire Alarm Description: Addition Of 9 Rtu's And 1 Mini Split Ac System RECORD
<br /> 6617 ASSOCIATED BLVD. ®Electrical Public Works
<br /> CITY OF EVERETT PERMIT SERVICES SUBJECT TO FIELD JACOB S. BUSH
<br /> APPROVED REVIEW DISCIPLE:BUILDING INSPECTION
<br /> EVERETT WA 98203 OM e of Community,Planning&Economic Development BY:Q. n 0/22/2
<br /> PLANNING DEPARTMENT DATE: 6122/2024 THIS SET OF
<br /> NAME: Jessica Jarvi STATUS:REVIEWED FOR PERMIT DRAWINGS SHALL BE 170 a00
<br /> DATE: 08/28/2024 ON JOB SITE AT ALL �Oaoss U�o"�°O�e Fa..eee.zoa..ers
<br /> TIMES
<br /> PROJECT DIRECTORY DEFERRED SUBMITTALS PROJECT SCOP PROJECT GENERAL NOTES DRAWING INDEX 20115925
<br /> • UPDATED PARKING STRIPING A. THE INTENT OF THESE DRAWINGS AND SPECIFICATIONS IS TO ASSIST THE CONTRACTOR IN PROVIDING ALL LABOR,MATERIALS AND SERVICES REGISTERED
<br /> • FIRE SPRINKLER DRAWINGS ASSOCIATED WITH NEW ROOFTOP MECHANICAL UNITS CHITECT
<br /> ARCHITECT OF RECORD ADDITION OF 2 NEW ACCESSIBLE PARKING STALLS AND REMOVAL OF 4 NECESSARY FOR COMPLETION OF ALL WORK SHOWN,PRESCRIBED,OR REASONABLY IMPLIED BUT NOT LIMITED TO THAT EXPLICITLY INDICATED IN
<br /> ARCHITECT:JACOB S.BUSH • ADDITION OF CONCRETE PADS FOR PERMANENT GENERATOR AND THE CONTRACT DOCUMENTS.
<br /> ADDRESS: 175 MONTROSE WEST AVENUE,SUITE 400 AUGER-COMPACTOR B. THE G.C.,AND ALL SUBCONTRACTORS SHALL VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB SITE PRIOR TO BEGINNING CONSTRUCTION JAKE S BUSH
<br /> AKRON,OH 44321 • ADDITION OF ROOFTOP MECHANICAL EQUIPMENT AND SHALL REPORT ANY DISCREPANCIES OR UNIDENTIFIED CONDITIONS TO THE ARCHITECT FOR RESOLUTION BEFORE ANY WORK IS BEGUN. STATE OF WASHINGTON
<br /> PHONE: 330-665-0660 • ADDITION OF WAREHOUSE LIGHTING C. ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES,ORDINANCES AND REGULATIONS AS ADOPTED BY LOCAL AUTHORITIES HAVING
<br /> • INSULATION UPGRADES IN NEWLY CONDITIONED SPACE JURISDICTION.
<br /> D. THESE DRAWINGS ARE NOT NECESSARILY DRAWN TO SCALE.THE CONTRACTOR SHALL,AT ALL TIMES,REFER TO THE WRITTEN DIMENSIONS ON y w 6.07.2024 EX 4.10.2026
<br /> PROJECT MANAGER _ p
<br /> NAME: PAUL GIERLACH THE DRAWINGS.NOTIFY THE ARCHITECT IMMEDIATELY IF THERE ARE MISSING OR CONFLICTING DIMENSIONS. >
<br /> EMAIL: PALLGIER GICRLACH INC.COM E. DIMENSIONS,DETAILS,NOTES AND/OR SYMBOLS THAT APPLY TO ONE UNIT,APPLY TO ALL UNITS IN LIKE SITUATIONS UNLESS NOTED OTHERWISE.
<br /> F. DETAILS NOTED AS"TYPICAL"SHALL APPLY IN ALL LIKE CONDITIONS UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE.WHERE NO SPECIFIC C Name,ReWration,EKdretlon
<br /> PHONE: 216.308.4242 DETAIL IS SHOWN,THE FRAMING,CONSTRUCTION OR OTHER COMPONENTS SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE CASES
<br /> OF CONSTRUCTION IN THIS PROJECT. -
<br /> VICINITY MAP G. WHENEVER AN ARTICLE,DEVICE OR PIECE OF EQUIPMENT IS SHOWN,INDICATED,OR REFERRED TO ON THE DRAWINGS OR IN THESE NOTES IN ARCHITECTURAL DRAWINGS
<br /> THE SINGULAR NUMBER,SUCH REFERENCES APPLY TO AS MANY SUCH ARTICLES AS REQUIRED TO COMPLETE THE INSTALLATION.THE STRUCTURAL ENGINEER CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS,TECHNIQUES AND PROCEDURES EMPLOYED IN THE PERFORMANCE OF THE Ti 0 TITLE SHEET&CODE SUMMARY
<br /> y. WORK IN,ON,OR ABOUT THE JOB SITE;CONTRACTOR SHALL COORDINATE AND VERIFY ALL WORK PERFORMED BY SUBCONTRACTOR'S. AS1.0 SITE PLAN
<br /> COMPANY:SMBH,INC. - H. THE CONTRACTOR AGREES TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE SAFETY CONDITIONS DURING THE HOURS OF AS3.1 SIGNAGE&GRAPHICS DETAILS
<br /> ADDRESS:1166 DUBLIN ROAD,SUITE 200 CONSTRUCTION OF THIS PROJECT;THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS, AS3.2 SIGNAGE&GRAPHICS DETAILS
<br /> COLUMBUS,OH 43215 AND THAT THE CONTRACTOR SHALL DEFEND,INDEMNIFY AND HOLD HARMLESS THE OWNER AND ARCHITECT FROM ANY AND ALL LIABILITY,REAL
<br /> PROJECT LOCATION OR ALLEGED,IN CONNECTION WITH PERFORMANCE OF WORK ON THIS PROJECT. A1.2 ROOF PLAN
<br /> PROJECT MANAGER A1.3 REFLECTED CEILING PLAN
<br /> NAME: SARAH FREIHEIT - / I. THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENTS ARE IN PLACE.THE CONTRACTOR SHALL PROVIDE ALL SHORING AND
<br /> PHONE: 614.481.9800 `)' BRACING NECESSARY TO ENSURE THAT STABILITY OF ANY AND ALL PARTS OF THE BUILDING DURING CONSTRUCTION. ATO ENLARGED PLANS
<br /> _ J. UNLESS SPECIFICALLY SHOWN OR NOTED ON THE DRAWINGS,NO STRUCTURAL MEMBER SHALL BE CUT,NOTCHED,BORED OR OTHERWISE A7.1 INTERIOR ELEVATIONS,DETAILS
<br /> MODIFIED WITHOUT PERMISSION/ACCEPTANCE OF THE STRUCTURAL ENGINEER OF RECORD. A10.5 BUILDING SIGNAGE AND GRAPHICS DETAILS
<br /> K. NEITHER THE ARCHITECT'S REVIEW NOR APPROVAL OF SHOP DRAWINGS SHALL RELIEVE THE GENERAL CONTRACTOR FROM RESPONSIBILITY FOR STRUCTURAL DRAWINGS
<br /> MECHANICAL, ELECTRICAL,&PLUMBING ENGINEERS DEVIATIONS FROM DRAWINGS OR SPECIFICATIONS UNLESS THE GENERAL CONTRACTOR HAS CALLED THE ARCHITECTS ATTENTION,IN WRITING, 50.00 GENERAL NOTES
<br /> rp TO SUCH DEVIATIONS AT THE TIME OF SUBMISSION;NOR SHALL REVIEW OR APPROVAL RELIEVE THE GENERAL CONTRACTOR OF RESPONSIBILITY
<br /> _ ',.h FOR ERRORS OF ANY SORT IN THE SHOP DRAWINGS. SO.01 SPECIAL INSPECTIONS
<br /> COMPANY:DIALECTIC - L. THE CONTRACTOR SHALL KEEP AN UP-TO-DATE RECORD OF"AS-BUILT"CONDITIONS OF THE WORK ON A SET OF DRAWINGS,FURNISHED BY THE S2.00 PARTIAL ROOF FRAMING PLAN
<br /> ADDRESS:310 W.20TH ST.,STE.100 ARCHITECT AND AT THE CONTRACTOR'S EXPENSE.UPON COMPLETION OF THE WORK,THAT SET SHALL BE RETURNED TO THE ARCHITECT S2.01 PARTIAL ROOF FRAMING PLAN
<br /> KANSAS CITY,M064108 COMPLETED AND NEATLY POSTED SHOWING ALL ADDITIONS,DELETIONS,CORRECTIONS AND REVISIONS OF THE ACTUAL CONSTRUCTION OF THE
<br /> PROJECT.THIS SHALL INCLUDE REVISIONS IDENTIFIED IN RFI'S,ASI'S,ADDENDUMS AND FIELD CHANGES.RECORD DRAWINGS SHALL BE SIGNED BY 54.00 FRAMING SECTIONS&DETAILS
<br /> PROJECT MANAGER _ THE SUBCONTRACTORS REPRESENTING ALL MAJOR TRADES FOR THE PROJECT AS WELL AS THE G.C.THE CONTRACTOR AND SUBCONTRACTORS MECHANICAL DRAWINGS
<br /> NAME: DREW HELLIGE 'jt SHALL PROVIDE ALL O&M MANUALS TO THE OWNER UPON PROJECT COMPLETION.IN THE EVENT A DISCREPANCY OCCURS BETWEEN THE M0.0 MECHANICAL NOTES,LEGEND,AND SPECIFICATIONS
<br /> PHONE: 816.997.9589 _ SPECIFICATIONS AND CONSTRUCTION DRAWINGS,THE HIGHER COST DESIGN SHALL PREVAIL. M1.0 WAREHOUSE ENLARGED PLAN-MECHANICAL PLAN
<br /> M. REQUIRED MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS SHALL BE MAINTAINED DURING DEMOLITION,CONSTRUCTION,REMODELING OR M2.0 1 MECHANICAL SCHEDULES AND DETAILS
<br /> ALTERATIONS AND ADDITIONS TO THE BUILDING.THE CONTRACTOR SHALL COORDINATE WITH THE AHJ FOR REVIEW&APPROVAL TO ANY PLUMBING DRAWINGS
<br /> BUILDING CODES TEMPORARY OR EXISTING ALTERATIONS THAT ARE REQUIRED TO ENSURE CODE-REQUIRED EGRESS IS MAINTAINED. P1.0 WAREHOUSEPLAN-PLUMBING PLAN
<br /> N. AUTOMATIC FIRE SPRINKLER,FIRE SUPPRESSION AND FIRE ALARM SYSTEMS WHEN TAKEN OUT OF SERVICE ARE REQUIRED TO HAVE THE AHJ
<br /> THE BUILDING DESIGN SHALL COMPLY WITH THE FOLLOWING CODES: v"MI NOTIFIED.THE DURATION OF TIME AND THE DATE MUST BE STATED TO INCLUDE THE DATE WHICH THE FIRE PROTECTION EQUIPMENT WILL BE P2.0 PLUMBING DETAILS&SCHEDULES
<br /> . 11 PLACED IN SERVICE,AS REQUIRED BY LOCAL CODE. ELECTRICAL DRAWINGS
<br /> AUTOMATIC FIRE DETECTION&SUPPRESSION SYSTEM ORDINANCE No.1902-92 ^`�+. +_ 0. POWER PANELS,WHICH SUPPLY POWER TO FIRE ALARM SYSTEMS,SHALL HAVE BRANCH CIRCUITS IDENTIFIED BY RED LABELS STATING"FIRE EO ELECTRICAL LEGEND&NOTES
<br /> 2021 INTERNATIONAL BUILDING CODE IBC&WAC 51-50
<br /> ALARM CIRCUIT".
<br /> E1.1 WAREHOUSE POWER PLAN
<br /> 2021 INTERNATIONAL EXISTING BUILDING CODE IEBC •��� � P. ALL COSTS FOR INSPECTIONS AND/OR TESTS,SHALL BE THE RESPONSIBILITY OF THE G.C.,UNLESS NOTED OTHERWISE.
<br /> ( ) ♦• '!I. E1.2 WAREHOUSE POWER PLAN
<br /> INTERNATIONAL PROP
<br /> ACCESSIBLE AND USEABLE BUILDINGS&FACILITIES,ANSI A117.1-2009&WAC 5150-005 ERTY MAINTENANCE CODE(IPMC),2015 EDITION&WAC 51-50 /l,- yy Q. THE G.C.SHALL OBTAIN ALL PERMITS AND PAY ALL FEES FOR PERMITS PRIOR TO START OF CONSTRUCTION.
<br /> " '>•M� R. TERMS:SHALL-ACTION THAT IS REQUIRED WITHOUT OPTION OR QUALIFICATION.FURNISH-TENANT SHALL BE RESPONSIBLE FOR OBTAINING. E2 WAREHOUSE LIGHTING PLAN
<br /> r • INSTALL-CONTRACTOR SHALL BE RESPONSIBLE FOR LABOR AND CONSTRUCTION EQUIPMENT NECESSARY TO SET IN PLACE,CONNECT, E3 ONE-LINE DIAGRAM
<br /> 2021 INTERNATIONAL FIRE CODE(IFC)&WAC 5154A CALIBRATE AND/OR TEST EQUIPMENT FURNISHED BY HIM OR OTHERS.PROVIDE-CONTRACTOR SHALL FURNISH AND INSTALL.
<br /> 2021 WILDLAND-URBAN INTERFACE CODE _ yF. E3.1 PANEL SCHEDULES&DETAILS
<br /> 2021 INTERNATIONAL MECHANICAL CODE(IMC)&WAG 51-52 1. 'i a IM E4 ELECTRICAL SPECIFICATIONS
<br /> 2020 NATIONAL ELECTRICAL CODE(NFPA 70)&WAG 296.468-010 ..;t- f - qx4 E4.1 ELECTRICAL SPECIFICATIONS
<br /> 2021 UNIFORM PLUMBING CODE(UPC)&WAC 51-56 �-
<br /> 2021 WASHINGTON STATE ENERGY CODE(WSEC)&WAG 51-11(C,R,APPENDIX)
<br /> EVERETT MUNICIPAL CODE,TITLE 19 ZONING
<br /> BUILDING INFORMATION(CODE ANALYSIS)
<br /> e-
<br /> NOTE:PROPOSED SCOPE DOES AFFECT THE BUILDING ALLOWABLE SQUARE FOOTAGES,EGRESS,NOR OCCUPANT 1 - •�•- ..a
<br /> LOADING.ALL INFORMATION SHOWN AS AN EXISTIGN CONDITION TO REMAIN AND PROVIDED HERE FOR REFERENCE.
<br /> - NORTH
<br /> ALLOWABLE EXISTING BUILDING CODE REFERENCE - -
<br /> MAXIMUM ALLOWABLE BUILDING HEIGHT: 75' t30'-0"-(NO CHANGE) TABLE503
<br /> MAXI MUM ALLOWABLE STORIES: 3 1-(NO CHANGE) TABLE 503
<br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
<br /> MAXIMUM ALLOWABLE AREA: 70,000 SF t217,700 SF-(NO CHANGE) TABLE 503
<br /> UNLIMITED AREA BUILDING: YES UNLIMITED AREA SECTION 507.4
<br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
<br /> THE FOLLOWING HAVE BEEN MET:
<br /> 1. BUILDING CLASSIFIED AS GROUP S1 IS LIMITED TOONE STORY IN HEIGHT. a
<br /> . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
<br /> 2. THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
<br /> SECTION 903.3.1.1
<br /> 3. SURROUNDED&ADJOINED BY PUBLIC WAY OR YARDS NOT LESS THAN 60'IN WIDTH.
<br /> EXISTING BUILDING COMPLIANCE METHOD:WORK AREA-ALTERATION LEVEL 2
<br /> CONSTRUCTION TYPE:HIS,UNPROTECTED/COMBUSTIBLE(EXISTING) SECTION 602.2 / a
<br /> SPRINKLERED:YES-AUTOMATIC SPRINKLER SYSTEM(EXISTING TO REMAIN) SECTION 903 L4 ' W
<br /> EXISTING BUILDING TOTAL: 217,700 BE
<br /> MAXIMUM COMMON PATH OF TRAVEL: TABLE 1006.2.1 0 W
<br /> S-1 100'
<br /> A3 75' Eoa ••�k
<br /> LENGTH OF TRAVEL: TABLE 1017.2
<br /> S-1 400'*** W
<br /> B 300' >o
<br /> A3 250'
<br /> "`THE FOLLOWING HAVE BEEN MET(SECTION 1017.2.2): 2 1 y - W
<br /> 1. THE PORTION OF THE BUILDING CLASSIFIED AS GROUP 8-1 IS LIMITED TO ONE STORY IN HEIGHT ® I II ® ® ® ® ® ® ® 1 - A W tz aN0
<br /> ' 'F-1PJI _ _ _ _ �1
<br /> 2. THE MINIMUM HEIGHT FROM THE FINISHED FLOOR TO THE BOTTOM OF THE CEILING OR ROOF DECK IS 24'-0' •LL• m I m mm N o N Q Q
<br /> MINIMUM II DIIIIJ m f�7 �,/I�■ O
<br /> 3. THE BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH mm mm fmd @1 m
<br /> SECTION 903.3.1.1 ° r _ U)Z
<br /> 3 - - - mmmm m ¢o UJ
<br /> OCCUPANT LOADS (DEMISED TENANT SPACE AS SHOWN) 7F ®®®® m mm mm mm . m 0 W m LU
<br /> USE GROUP AREA OCC. LOAD FACTOR OCC.LOAD 8 '
<br /> CURRENT SCOPE 1004.5 1
<br /> PRIMARY 1 m PltoPosED CAGE LOCATION. I Revisions/Submissions
<br /> SEEBHEETA7.0 ID Description Date
<br /> S-1 WAREHOUSE I STORAGE 211,773 W. 424 4 • - - - - - - - - - - qq{q�y{q - PERMITSET 06.07.2024
<br /> ACCESSORY NOTE:PROVIDE OR COLD MINT
<br /> ING,
<br /> NTING,
<br /> NUMB SAAMAAid
<br /> EXTERIOR DOOR NUMBERING I PAINTING IN THIS
<br /> A3 ASSEMBLY 4,228 15 282 ON THIS
<br /> SHEET REFERENCE.
<br /> NUMBERING BHOWN APPpq W
<br /> ON THIS PUN FOR REFERENCE. j
<br /> EXISTING OFFICE LORE AREA. gqgqr�{qqqqqq
<br /> EXTERIOR WALL SURFACES IN THIS AREA TO BE (Tryry7n{7 LLTTryry11 LryTTry111 SEE SHEET AT.OFOR INTERIOR 1do'd
<br /> B BUSINESS 1,699 150 12 PAINTED TO MATCH CHEDULE FOR EXISTING ADJACENT SPACES. j H{ H{ H{ m m r7, r7, my FINISH UPGRADES
<br /> TOTAL TENANT AREA: 217,700
<br /> 5 - BEE FINISH SCHEDULE FOR DETAILS.
<br /> DEMISING WALL TO BE PAINTED MATCH EXIBTI
<br /> TOTAL OCCUPANT LOAD: 718 I ADJACENT DEMISING WALLS.SEEE FINISH SCHEDULE
<br /> LE
<br /> FOR DETAIL AND SPECS. IS
<br /> BUILDING EGRESS COMPONENTS CAPACITY(DEMISED TENANT SPACE ASSHOWN) III I I I I I I I I I I I I I I I I I III I
<br /> CAPACITY OF EGRESS COMPONENTS REQUIRED: CODE REFERENCE
<br /> SECTION 1005.3.2
<br /> 0.2"PER OCCUPANTX 7180CCUPANTS=143.6"OF EGRESS REQUIRED 6 - - - - - t
<br /> PROPOSED CAGE LOCATON.
<br /> SEESHEETA7.0
<br /> EGRESS COMPONENTS PROVIDED: . . .
<br /> .I.C. m
<br /> 24 EGRESS DOOR(S)AT 3T CLEAR=792"(3,960 OCC)
<br /> TOTAL EXIT CAPACITY=792"(3,960 OCC.) _ oa M
<br /> TOTAL NUMBER OF EXITS REQUIRED:2 SECTION 10D6.2.1 7 0 0 0
<br /> TOTAL NUMBER OF EXITS PROVIDED:25 e e
<br /> INTERIOR FINISHES(SPRINKLERED) ®2o24JA°oBs.BUSH
<br /> Project Number: 763298-01
<br /> INTERIOR EXIT STAIRWAYS& CORRIDORS&ENCLOSURE ROOMS 8 ENCLOSED FLOOR FINISH y y Scale: AS NOTED
<br /> OCCUPANCY RAMP
<br /> FOR ACCESS SPACES (SECTIONBOd.4.1) 1 � � Drawn By: JSR
<br /> PASSAGEWAYS STAIRWAYS&RAMPS
<br /> -`•`• 1
<br /> Checked By: PG
<br /> S-1(WAREHOUSE) CLASS'C' CLASS'C' CLASS'C' CLASSTPIDOC-FF-1 a e e e e e e e e e e e e e e e e Date: 06/07/2024
<br /> IBC TABLE803.s :-.-. :': Issue: PERMIT SET
<br /> : . . . : : :a:LL: : : : : : : : :LL:LL: : : . : : :
<br /> . . . .Q. .
<br /> INTERIOR FINISH CLASS A:
<br /> -FLAME SPREAD RATING 0-25 SECTION 803.1.1 Drawin Title:
<br /> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
<br /> r
<br /> 9
<br /> INTERIOR FINISH CLASS B-FLAME SPREAD RATING 26-75
<br /> INTERIOR FINISH CLASS C-FLAME SPREAD RATING 76-200 0 ;- LL LL LL LL LL LL LL LL LL LL LL LL LL LL TITLE SHEET&CODE
<br /> SPACES OTHER THAN EXITS&CORRIDORS-SMOKE DEVELOPED RATING 450 OR LESS SECTION 803.1.1 SUMMARY
<br /> NOTE:
<br /> 1. INTERIOR FINISHES SHALL MEET OR EXCEED SLIP RESISTANCE REQUIREMENTS OF 0.6 COF MINIMUM. -
<br /> OVERALL PLAN
<br /> NORTH T1 .0
<br /> NOR
<br />
|