2021 WASHINGTON STATE MECHANICAL CODE TABLE 403.3.1.1 VENTILATION SUMMARY <br /> OCCUPANCY CATEGORY PEOPLE AREA OUTDOOR OCCUPANCY OCCUPANCY CLASSIFICATION CALCULATED I ZONE PEOPLE LFRVIP RII AREA-(Az) ZONE AIR BREATHINGZONE ZONE OUTDOOR ZONE PRIMARY PRIMARY OCCUPANT UNCORRECTED SYSTEM CORRECTED PROVIDED <br /> OUTDOCRAIR AIRRATE-(Ra) DENSITY OCCUPANCY OCCUPANCY EXPECTED TO DISTRIBUTION OUTDOORAIRFLOW AlRFLOW(Voz) AIRFLOVV(Vpz) OUTDOOR AIR DIVERSITY RATIO OUTDOOR AIR VENTILATION OUTDOOR OUTDOOR ARCHITECT <br /> RATE-(RP) DENSITY OVERRIDE OCCUPY THE EFFECTIVENESS- -(Vbz) Voz=Vbz/Ez FRACTION(Zp) (D) INTAKE(Vou) EFFICIENCY AIRFLOW(Vot) AIRFLOW OF <br /> ZONE-(Pz) Ez Vbz=RVPz+Ra'Az Zp=VozMpz Vou=D`RpPz+RaAz <br /> CIEWPERS CFWSQ.FT. P/1,000SQ.FT. SdFT. CFM CFM Ev CFM CFM RECORD <br /> RTU-18-22 <br /> Library SheMnq Area 10.0 0.06 1 - STORAGE-Warehouses 1 4275 71245 0.8 4275 5343 24040 0.22 4275 5343 JACOB S. BUSH <br /> SYSTEM POPULATION INCLUDING DIVERSITY Ps= MAX. - 0.22 1.00 4275 0.80 5343 5345 <br /> RTU-23-26 <br /> Bulk Storane 10.0 0.06 STORAGE-Warehouses 2993 49887 0.8 2993 3742 22100 0.17 2993 3742 <br /> SYSTEM POPULATION INCLUDING DIVERSITY(Ps)= MAX. - 0.17 1.00 2993 0.80 3742 3760 <br /> AHU-1 - - <br /> QA/OC 10.0 0.06 STORAGE-Warehouses 181 3010 0.8 181 226 1600 0.14 181 226 nsM°nnho�oi1u9z1S-40o <br /> SYSTEM POPULATION INCLUDING DIVERSITY Ps= MAX.Zp- 0.14 1.00 181 1 0.80 1 226 <br /> ROOFTOP UNIT SCHEDULE-HEAT PUMP <br /> IDENTIFICATION PERFORMANCE DX COOLING DATA HEAT PUDMAPAHEATING ELECTRIC HEATING COIL ELECTRICAL PHYSICAL NOTES QC��pE Wa1Hjj� <br /> R� <br /> MARK MANUFACTURER MODEL NOMINAL SUPPLY OUTSIDE EXT. PER EAT AMBIENT TOTAL SENSIBLE OUTPUT@ COP EAT LAT INPUT OUTPUT MOTOR VOLTS/PH MCA MOCP APPROX. <br /> 2 <br /> TONNAGE AIRFLOW AIRFLOW <br /> STATIC O.A.T. 47-F WEIGHT <br /> RTU- TONS CFM CFM IN WC 'F DBIWB "F BTU/HR BTUIHR BTUIHR -F "F kW BTUIHR HP QTY AMPS AMPS LBS <br /> 18 TRANE WMJ150 12.5 4,810 1,070 0.4 12.3 78.7/63.4 95 143,270 126,670 140,580 3.8 59.0 82.0 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 gsD17 <br /> 19 TRANE WHJ150 12.5 4,810 1,070 0.4 12.3 78.7/63.4 95 143,270 126,670 140,580 3.8 59.0 82.0 36.0 122,760 2.9 2 48OV-3PH 94.0 100 2,250 1-17 <br /> 20 TRANE WHJ150 12.5 4,810 1,070 0.4 12.3 78.7/63.4 95 143,270 126,670 140,580 3.8 59.0 82.0 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 AL4s"' <br /> 21 TRANE WHJ150 12.5 4,810 1,070 0.4 12.3 78.7/63.4 95 143,270 126,670 140,580 3.8 59.0 82.0 36.0 122,760 2.9 2 48OV-3PH 94.0 100 2,250 1-17 06/07/2024 <br /> 22 TRANE WHJ150 12.5 4,810 1,070 0.4 12.3 78.7/63.4 95 143,270 126,670 140,580 3.8 59.0 82.0 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 <br /> 23 TRANE WHJ150 12.5 5,525 940 0.4 12.3 78.2163.2 95 145,990 135,330 139,450 3.8 61.2 91.3 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 <br /> 24 TRANE WHJ150 12.5 5,525 940 0.4 12.3 78.2/63.2 95 145,990 135,330 139,450 3.8 61.2 91.3 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 Name,aegistmlion,Expiration <br /> 25 TRANE WHJ150 12.5 5,525 940 0.4 12.3 78.2163.2 95 145,990 135,330 139,450 3.8 61.2 91.3 36.0 122,760 2.9 2 480V-3PH 94.0 100 2,250 1-17 <br /> 26 TRANE WHJ150 12.5 5,525 940 0.4 122 78.2EJ 95 145,990 135,330 139.450 3.8 81.2 91.3 36.0 122,760 2.9 2 48OV-3PH 94.0 100 2.250 1-17 laDialectic <br /> NOTES: <br /> 1) PROVIDE FACTORY FABRICATED 24"HIGH ROOF CURB. ENGINEERING <br /> 2) SET M INIMUM OUTSIDE AIR AS SPECIFIED ABOVE.OUTSIDE AIR DAMPER SHALL MODULATE POSITION TO MAINTAIN REQUIRED QUANTITY OF OUTSIDE AIR AS SUPPLY FAN VARIES SPEED.OUTSIDE AIR DAMPER SHALL FULLY CLOSE ON UNIT SHUTDOWN. D;alam;c,I.. T 816-997-9601 <br /> 3) PROVIDE FACTORY INSTALLED LOW-LEAK DRY BULB ECONOMIZER WITH FAULT DETECTION AND DIAGNOSTICS. 310 W 20th So-t.swta 100 F 81-7-9692 <br /> 4) PROVIDE FACTORY MOUNTED POWER EXHAUST. Kaesas City Mo 64108 DlaledlcEng.com <br /> Waehingt°n Ced;gcate of <br /> 5) PROVIDE FACTORY MOUNTED WEATHERHOOD AND BIRDSCREEN. Aulh°rmar°a Nambarmzss capydgm zoza <br /> 6) PROVIDE LOUVERED HAIL GUARDS. Ths sheers pan onne coestmdbn aopaments.Dravdogs. <br /> 7) PROVIDE 5 M INPTE COMPRESSOR RESTART TIME DELAY. spaaepauoea ane char sheets apply sea ease to ha ramawaa ro <br /> 8) PROVIDE FILTER RACK AND TWO SETS OF M ERVA3 FILTERS. t°rat.°ama ahawe eramr a;agremmatic mprasaetaa°"aed may <br /> 9) PROVIDE SINGLE ZONE VAV. moeircarooa reamed o,wof mdtos;re-Rit sale'golpmema"d <br /> 10) PROVIDE FA CTORY CONDENSATE OVERFLOW SWITCH. mrana aI° d.vadry l«ab°ea aed dire-mas°fall amhl�actural <br /> and simdurel elements per their respective tl°cumenls,as iM1ese <br /> 11) PROVIDE FACTORY POWERED WEATHERPROOF GFCI CONVENIENCE OUTLET.OUTLET SHALL BE POWERED FROM LINE SIDE OF DISCONNECT. elements are shown omyror referees and regwre.edd°aron <br /> 12) DISCONNECT SWITCH TO BE PROVIDED BY ELECTRICAL CONTRACTOR. poor to fabdpagoeorooeswod-Eoymeer nas no l;ab;ity ror me <br /> 13) PROVIDE WITH SCR ELECTRIC HEAT CONTROL. eo9meer has not signedsnd sealed. <br /> ayat ,or raey wa a <br /> 14) PROVIDE FACTORY APPLIED CORROSION RESISTANT EPDXY COATING ON EVAPORATOR AND CONDENSER COILS. Prolaptx-20202315.20 <br /> 15) PROVIDE WITH SUPPLY AIR TEMPERATURE SENSOR. <br /> 16) PROVIDE WITH FACTORY MOUNTED BACNET DDC UNIT CONTROLLER. <br /> 7) CONTRACTOR SHALL INSALL ALL COMPONENTS SHIPPED LOOSE TO THE FIELD. <br /> AIR HANDLING UNIT SCHEDULE GRILLE,REGISTER AND DIFFUSER SCHEDULE <br /> IDENTIFICATION PERFORMANCE DX COOLING DATA COIL ELECTRICAL PHYSICAL NOTES MARK MANUFACTURER MODEL TYPE NECK SIZE FACE SIZE FRAME TYPE FINISH NOISE CRITERIA ACCESSORIES <br /> VEL <br /> MARK MANUFACTURER MODEL NOMINAL SUPPLY OUTSIDE EXi. EAT AMBIENT TOTAL SENSIBLE INPUT OUTPUT MOTOR VOLTSIPH MCA MOCP APPROX. L"XW" L"XW" <br /> TONNAGE AIRFLOW AIRFLOW STATIC O.A.T. WEIGHT A TITUS DBD-44-LL DROPBOX DIFFUSER 26"X26" 24"X10" DUCT MOUNTED WHITE <30 LNR,OBD <br /> AHU- TONS CFM CFM IN WC °F DBIWB °F BTUIHR BTUIHR kW BTUIHR HP QTY AMPS AMPS LEE B TITUS 30OR5 I SUPPLY REGISTER 18"X10" 20"X12" I DUCT MOUNTED WHITE <30 OBD <br /> 1 TRANE TEM6AOC48 4 1,600 230 0.5 75.3I62.3 95 45,033 36,529 5.8 19,676 1.0 075 208V-1 PH 49.0 50 200 1.3 <br /> ACCESSORIES <br /> NOTES: LNR-l"LINER,OBD-OPPOSED BLADE DAMPER <br /> 1) SET MINIMUM OUTSIDE AIR AS SPECIFIED ABOVE.OUTSIDE AIR DAMPER SHALL FULLY CLOSE ON UNIT SHUTDOWN. APPROVED EQUALS',AES INDUSTRIES(DROPBOX),M ETALAIRE,PRICE. <br /> 2) PROVIDE WITH CONDENSATE DRAIN OVERFLOW SWITCH TO TURNOFF UNIT IF TRAP BECOMES CLOGGED. <br /> 3) ELECTRICAL CONTRACTOR TO PROVIDE DISCONNECT SWITCH. <br /> HEAT PUMP CONDENSING UNIT SCHEDULE <br /> IDENTIFICATION PERFORMANCE DX COOLING DATA HEAT PUMP HEATING DATA ELECTRICAL PHYSICAL NOTES <br /> MARK MANUFACTURER MODEL NOMINAL AMBIENT O.A.T. EAT TOTAL SENSIBLE SEER OUTPUT@ OUTPUT@ COP FAN COMP VOLTSIPH MCA MOOR APPROX. <br /> TONNAGE 17°F 47°F WEIGHT <br /> HP- TONS "F °F DBIWB BTUIHR BTUIHR BTUIHR BTUIHR QTY QTY AMPS I AMPS LBS <br /> 1 TRANE 4TWR5048 1 4 95 75.31691 1 45,033 36,529 16 28,400 44,000 4.0 1 1 208VAPH 1 26.0 1 40 300 1-5 <br /> NOTES: <br /> 1) PROVIDE PHENOLIC EPDXY COATING ON CONDENSER COIL. <br /> 2) PROVIDE LIQUID LINE SIGHT GLASS,MOISTURE INDICATOR,AND FILTER DRYER FOR EACH CIRCUIT. <br /> 3) PROVIDES MINUTE TIME DELAY ON COMPRESSOR RESTART. <br /> 4) ELECTRICALCONTRACTOR TO PROVIDE DISCONNECT SWITCH. HVAC EQUIPMENT w <br /> 5) PROVIDE LOWAMBIENT TO OPERATE UNIT TO O°F AMBIENT OUTDOOR TEMPERATURE. GASKET o <br /> (4) 'TEKS"SCREWS (4) "TEKS"SCREWS <br /> 18 GAUGE TIE DOWN RESTRAINT <br /> COUNTERFLASHING W <br /> TREATED WOOD NAILER ROOFING LL/ <br /> SECURED TO CURB CANT STRIP Y� <br /> NOTES: 1) ROOF RAILS SHALL RUN ALONG THE LONG DIMENSION OF EACH UNIT. ROOF CURB W <br /> 2) PROVIDE TWO ROOF RAILS FOR EACH UNIT. PROVIDE 13.5"RAIL HEIGHT, ROOFING <br /> SS CLAMPS INSULATION <br /> 3) ES-5/5B (OR APPROVED EQUAL) FOR USE ON DECKS WITH RIGID INSULATION. <br /> CAP AND BOOT PACKAGE ROOF INSULATION <br /> 4) ES-2/2B OR APPROVED EQUAL) FOR USE ON DECKS WITH LIGHTWEIGHT FILL OR TAPERED <br /> "PATE"MODEL PCC-5 FRAMED OPENING FOR Uj <br /> INSULATION. SUPPORT AND CONNECTION. <br /> ROOF STRUCTURE <br /> LAG BOLT REFER TO STRUCTURAL m M <br /> CURB "PATE" I� I� DRAWINGS. <br /> MODEL PCA-1 EQUIPMENT p Lu N <br /> COUNTERFLASHING NOTE: ROOF EQUIPMENT SHALL BE SET LEVEL AND SIT ON STEEL ANGLES (NOT ON METAL ROOF DECK)COORDINATE W <br /> NAIL ROOF SLOPE WITH ARCHITECTURAL AND PROVIDE SLOPED-BASED ROOF CURB AS REQUIRED FOR LEVEL EQUIPMENT '^ Q Q <br /> ROOF INSULATION INSTALLATION. v♦ U m F <br /> WOOD NAILER O z H_ <br /> EQUIPMENT SUPPORT RAIL SUPPORT FRAMING SIZE AND ATTACHMENT TO STRUCTURE/FRAMING SHALL BE AS RECOMMENDED BY CURB <br /> CANT STRIP MANUFACTURER BASED ON EQUIPMENT SUPPORTED AND PROJECT WIND ZONE CRITERIA. CURB MANUFACTURER SHALL Q W <br /> BASE PLATE ROOFING BY OTHERS (TYP) PROVIDE CERTIFIED CALCULATIONS AND ATTACHMENT DETAILS WITH CURB SUBMITTALS. ^ W <br /> ROOF STRUCTURE ROOF INSULATION DECK INSULATION RESTRAINT BRACKETS UTILIZED TO SECURE ROOFTOP AIR CONDITIONERS SHALL BE DESIGNED FOR PROJECT WIND SPEEDS. in uP CO LU <br /> VERIFY REQUIREMENTS WITH STRUCTURAL ENGINEER. STRUCTURAL WIND LOAD CALCULATIONS AND/OR STATE NOTICE OF <br /> ACCEPTANCE SHALL BE AVAILABLE FROM THE MANUFACTURER. RESTRAINT BRACKET QUANTITY TO BE DETERMINED BY <br /> NOTES- PROJECT SPECIFIC CALCULATIONS(IF REQUIRED FOR SPECIFIC LOCATION).AT MINIMUM, PROVIDE 4 BRACKETS PER CURB, Revisions)Submissions <br /> 1. USE SINGLE ROOF PENETRATION FOR ALL CONTROL WIRING, POWER WIRING,AND ROOF RESTRAINT BRACKETS SHALL BE ATTACHED TO ROOF CURB WITH (4) #12 TEN SCREWS,AT 2"O.C. RESTRAINT BRACKETS ID Description Dale <br /> REFRIGERANT LINES. STRUCTURE TO BE AES INDUSTRIES MODEL AWS OR EQUAL. <br /> 2. INSULATE REFRIGERANT LINES PER MANUFACTURER'S RECOMMENDATIONS. PATE ES-5/58 PATE ES-2/2B PERMIT SET 06.07.2024 <br /> 5 PIPE ROOF PENETRATION DETAIL EQUIPMENT SUPPORT RAIL DETAIL ROOFTOP UNIT CURB DETAIL <br /> NOT TO SCALE NOT TO SCALE 1 NOT TO SCALE <br /> SUPPORT FROM STRUCTURE INSULATE SUCTION LINE FLAT FILTER SECTION <br /> ABOVE WITH CHANNEL AND WITH 1" FLEXIBLE <br /> THREADED ROD UNICELLULAR INSULATION. FLEXIBLE DUCT CONNECTOR <br /> SUPPLY AIR DUCT EXTEND DUCT UP <br /> FAN SECTION OUTSIDE AIR DUCT WITH T ROUGH ROOFTOP UNIT <br /> TO <br /> T BALANCING DAMPER <br /> FLEXIBLE DUCT CONNECTOR 1 <br /> - TRANSITION AS <br /> - J REQUIRED TO <br /> U CENTER DROP <br /> BOX DIFFUSER <br /> \ BETWEEN <br /> STRUCTURAL <br /> LINED RETURN AIR DUCT. MEMBERS. <br /> REFER TO PLAN FOR SIZE.- ©2024 CESO,INC. <br /> SUPPORT DROP Box Project Number: 763298-01 <br /> DIFFUSER FROM ) <br /> L J STRUCTURE ABOVE WITH Scale: AS NOTED <br /> ALL-THREAD ROD PER <br /> MANUFACTURER'S Drawn By: WBL <br /> INSTALLATION <br /> 22 GAUGE GALVANIZED DROP BOX DIFFUSER ASSEMBLY. INSTRUCTIONS. Checked By: CLK <br /> AUXILIARY DRAIN PAN MOUNT BOTTOM OF DIFFUSER <br /> APPROXIMATELY 3'-0"BELOW Date: 06/07/2024 <br /> LOWEST STRUCTURE. Issue: <br /> CONDENSATE OVERFLOW DRAIN CONDENSATE DRAIN. REFER TO PLUMBING PLAN FOR SIZE AND ROUTE. NOTE: REFER TO PLANS FOR DUCT SIZE. INSTALL DIFFUSER IN ACCORDANCE WITH <br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. Drawing Title: <br /> MECHANICAL <br /> AIR Q HANDLING UNIT INSTALLATION DETAIL A PLENUM SUPPLY DROP DETAILS SCHEDULES <br /> 4 NOT L NOT TO SCALE <br /> AND DETAILS <br /> M2.0 <br />