My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 12:03:14 PM
Creation date
1/2/2026 12:00:02 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-044
Year
2024
Notes
Waste Water System and Process Water System Tank Cleanout
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND GENERAL NOTES <br /> X HYDRAULIC PIPE ANCHOR 1. FOR AIR SYSTEM SEE DRAWING TNM111_AIR_COMPOSITE. <br /> HYDRAULIC PIPE GUIDE <br /> 7 Q 8 HYDRAULIC LOW POINT DRAIN T <br /> 2. FOR POTABLE AND PROCESSED WATER SYSTEM SEE <br /> HYDRAULIC RETURN SINGLE BLOCK AND BLEED DRAWING TNM110_WTR_COMPOSITE. <br /> VALVE CONFIGURATION <br /> D�DG HYDRAULIC SUPPLY DOUBLE BLOCK AND BLEED 3. IN ALL TUNNELS, UTILIDORS, AND TRENCHES WITH HYDRAULIC <br /> VALVE CONFIGURATION PIPING (EXCEPT PEDESTRIAN TUNNELS), PROVIDE THE FOLLOWING <br /> PIPE SUPPORT FLOOR COATING: <br /> NEOGARD 70714/70715 CHEMICAL RESISTANT PRIMER: 2 <br /> - - - - - - - - - - - - - - - - - - - - COMPONENT 100% SOLIDS EPDXY RESIN WITH A CYCOALIPHATIC <br /> AMINE HARDENER, AND <br /> NEOGARD 70714/70715 100% SOLIDS EPDXY (EP) COATING FINISH <br /> MATCH LINE SEE DWG UGM113 -I ®SEE STRUCTURAL DRAWING S665, DETAIL 10 FOR GUIDES. <br /> 5�SEE STRUCTURAL DRAWING S665, DETAIL 1 FOR ANCHORS. <br /> ❑ I ©FOR HYDRAULIC SUPPLY DOUBLE BLOCK AND BLEED VALVE <br /> ASSEMBLY, SEE DETAIL 3/M5XX. FOR HYDRAULIC RETURN SINGLE <br /> zBLOCK AND BLEED VALVE ASSEMBLY, SEE DETAIL 4/M5XX. <br /> FOR HYDRAULIC BERM CONTAINMENT DETAIL, SEE STRUCTURAL <br /> I 3"IW I DRAWING 5/S305. <br /> ❑ <br /> "x4" PIW I ®SEE STRUCTURAL DRAWING S665, DETAIL 8 FOR HYDRAULIC PIPE <br /> I <br /> SUPPORTS. <br /> I Eg-->SEE STRUCTURAL DRAWING S665, DETAIL 9 FOR HEAVY DUTY <br /> IEl HYDRAULIC PIPE SUPPORTS.I I <br /> PIW WALL ANCHOR <br /> SEE 1 10 SEE DRAWING 40-26-MXXX, DETAIL X FOR SPRAY SHIELD. <br /> UGM118 M551 1 DSEE ETAIL/M605-11 FOR HYDRAULIC SUPPLY LOW POINT DRAIN <br /> I I I I <br /> SP SUMP WITH PUMP PIW CLEANOUT I 12 SEE 2/M605-11 FOR HYDRAULIC RETURN LOW POINT DRAIN <br /> 73 30"O X 4' DEEP SEE DETAIL. <br /> SEE DETAIL A a UGM118 M551 <br /> UGM118 U�GM�506 0 13 SEE 2/M59X FOR HYDRAULIC SUPPLY HIGH POINT VENT DETAIL. <br /> 4"IW CLEANOUT SEE DETAIL 2 1/2 LIE>SEE 3/M59X FOR HYDRAULIC RETURN HIGH POINT VENT DETAIL. <br /> UGM118 M584 Z I 6 <br /> - 2H2 2H1 2H16 2 1H8- 4 T <br /> to REFERENCE DRAWINGS <br /> 1�41NVS— N N dS Nb5 NVS 3"PPCW T7N8 �-� I w 1. PIW CONTAINMENT PIPE ASSEMBLY: SEE LL <br /> N w UGM118 M551 <br /> 3"PPCW 1 2"D 2"D viH12 I I UP 3-1/2' CRP z <br /> (1-1/2' BELOW CEILING) 2 = 2. PIW CARRIER PIPE CENTRALIZERS: SEE 4 <br /> 4"IW 1"PPCW 1 I Q UGM 1 18 M551 <br /> z 7'-6" -2 2'-2" 12'-0" r6" <br /> 0 <br /> i 3. PIW CONTAINMENT PIPE SUPPORT: SEE 6 <br /> UGM118 M551 <br /> 11 _ _ 2" HYDRAULIC <br /> _ T ��-7 SUPPLY <br /> a I 3"D (5❑BELOW ^UGM118 UGM503 4" HYDRAULIC CONSTRUCTION NOTES <br /> 4"IW CEILING) RETURN 1 PROVIDE PPCW PIPE, LABEL PIPE AS "PUMPED PROCESS COLD <br /> VALVE ASSEMBLY: 40-26-5-1 <br /> ❑ PIPE RUNNING 4'-6" WATER". <br /> VALVE ASSEMBLY: 40-26-R-1 I BELOW CEILING, 6" <br /> TYP DN 3' (4'-6" BELOW CEILING) I OFF WALL <br /> 13 VALVE NUMBER: 40-26-S-2 <br /> 2"HYDRAULIC SUPPLY G <br /> 4" HYDRAULIC RETURN—,, 14 VALVE NUMBER: 40-26-R-1 <br /> I ❑ 11 VALVE NUMBER: 40-26-S-2 <br /> 12 VALVE NUMBER: 40-26-R-1 <br /> I UGMt18M548 4" HYDRAULIC FLUID FILL 6%4" PIW <br /> FO IN THIS <br /> AREA SEE DWG M718 o <br /> UP 1' (6" BELOW o o ❑ Z 6"PSAN I 0.9 1 <br /> CEILING, 1' FROM WALL) 1 1/2"CW <br /> 1 1/2"HS (3) --------- ----------------------- - ----- ------------- - EIFDG 40f25 I�� <br /> 2"HR (3) PIPE RUNNING 14" <br /> BELOW CEILING 4"x6"PIW SUPPORT WITH HANGERS I I�GM110.JGM1111UGM112IUGM1131_1GM114jj N <br /> _ FLEX NO GUIDES THIS SECTION <br /> t 4"IW COUPLING - - - - - - - - I - - ---- <br /> SEE 40-026-M718 °' �I1GM11 �UGM116UGM117UGM1181 GM11dj <br /> MATCH LINE SEE DWG UGM123 FOR FOR CONTINUATION 8"_0" I '_-___ _-___ _-___ <br /> 4%6"PIW LEAK DETECTION/DRAIN IIPGM12gUGM121NGM122jUGM123ttPGM121 <br /> 5 <br /> 4"HYDRAULIC FLUID FILL ON 4" SEE UGM12�UGM126tGM1271GM128UGM12 CO <br /> (18" BELOW CEILING UGM118 M551 - - -- -- - - - - <br /> PARTIAL UNDERGROUND PLAN N BLDG 4oi27 <br /> SCALE: 1/8"=1'-O" FINISH FLOOR EL. 92'-0" <br /> KEY PEAN <br /> F�MEERS <br /> ISSUED FOR CONSTRUCTION scALE: NON8' 4' 0 4' 8' 16, <br /> PROFESSIONAL STAMP & SIGNATURE <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY FSi DATE 03.14.24 SCALE: <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> M. cH ACCEPTABILITY PIKE 7-n-sz PARTIAL UNDERGROUND PLUMBING PLAN qo THIS DESIGN AND OR H K W8861360 03.14.24 <br /> RECORD DRAWING ISSUED TO OWNER MGM DJH 06-30-94 E 40-027 BUILDING - RECORD 15477651 SAZAN 08.05.16 �p�°� ,0 SPECIFICATION IS APPROVED PIKE 7-17-92 SHEET <br /> A 787 FA RECORD SET 555886 WH J. MENIKETTI 06.22.07 F MOVED AIR&WATER TO COMPOSITES - JPO - 03.23.17 �O` ® `" -APPROVED BY DEPT. BATE PIKE 7-17-g2 TITLE 737 NORTH LINE - 40-26 WING TANK CLEANOUT M KED UGM 118 <br /> B 787 SURGE LINE - RECORD WH SAG 10.15.12 G 737 NORTH LINE - 40-26 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 �i• _EC <br /> LMM 7-17-92 BUILDING 40-026 <br /> JOB N0. COMP N0, <br /> C PIW SYSTEM EVAL JD WL/JJ 04.13.15 H 737 NORTH LINE - HYDRAULICS W8861360 FSi KMC OL25.24 APPROVED <br /> 7-17-92 <br /> D 787 PS SELANT HEAT AND HUMIDIFICATION W2638149 FSI REG 12.17.15 APPROVED MECHANICAL MASTER COL. N.3-N.7/7-9 EVERETT, WA 1DWG No. 40-026-UGM118 <br />
The URL can be used to link to this page
Your browser does not support the video tag.