3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2026-01-02 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/2/2026 12:03:14 PM
Creation date
1/2/2026 12:00:02 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2407-044
Year
2024
Notes
Waste Water System and Process Water System Tank Cleanout
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND <br /> AWR = AQUEOUS WASH RETURN <br /> T <br /> 9.5 10 0.5 1 1 1 1 <br /> GENERAL NOTES <br /> 2" TEE WITH CAP FOR 1. FOR TOILET ROOM PLAN AND RISER DIAGRAMS <br /> SEE DWG M1M503 <br /> FUTURE CONNECTION (TYP) TEE FROM EXISTING. 1/2" DOM. CW, ROUTE 2. FOR TOILET ROOM WASTE AND VENT PIPING SIZES <br /> SEE DETAIL 2 ON FENCE AND DOWN TO FILTER AND S/0 <br /> 1M129 M501 1/2" CW & 2" V DN TO EWC-1 VALVE 1/2" CW & 2" V DN TO EWC-1 I I SEE DWG M1M505 <br /> 2 1/2" PSAN DN TO <br /> HUB DRAIN 2 1/2" PSAN 1 CW 1 2"CW DN TO DRINKING FOUNTAIN 3. PIPING INSTALLATION SHALL CONFORM TO UNIFORM <br /> / MATCHLINE / PLUMBING CODE AND LOCAL REGULATIONS. <br /> 4" CW DN SEE DWG 1M124 1/2 <br /> O 2" A DN 3" 1 2 ��OWT4'A� 4. SEE 40-026-MOi FOR PIPING SPECIFICATIONS <br /> I - - - - n - - - - FILTER P <br /> A A II q <br /> 7- 3" V DN DIN TAP <br /> OE REMOVAL NOTES <br /> w 4" HUB DRAIN MEZZANINE ABOVE <br /> TOILET ROOM REMOVE AQUEOUS WASH AW PIPE LABEL ON <br /> 51� 2"V A CLOSE TO STEEL BEAMS TOWTOTE I ( ) <br /> 3"AW E 40-026-TN-P/10-CW-6 BOTTOM OF BEAMS EL = 117'-9" BOP-1 40-026-TN I <br /> 1 1/2"AWR 40-026-TN-P/10-CW-5 ENTIRE RUN OF PIPING. <br /> P 11-CW-1 <br /> 40-026-TN-P/10-CW-4 1 1/2' A 3" V TO MEZZANINE TOILET ROOM. 2 REMOVE AQUEOUS WASH RETURN (AWR) PIPING. <br /> 2" SAN CAPPED 1 1/2" SAN HOLD TO 2ND FLOOR FRAMING. 40-026-TN <br /> EXPANSION 40-026-TN-P/10-CW-3 AT FLOOR. UP TO EWC 2A 40-0P/11 W-2 <br /> TANK <br /> x ��x/ x x x x X -y-1 <br /> E-L 2"W Up 3"CW UP O O O� 40-026-TN-P/10-CW-9 3 C LO 1" H & CW AND 2" SAN <br /> UP TO F 5 TYP <br /> CO 2 W YAW UP� 0 40- 26 N-P/10- HA(2) 3/4" <br /> 1 1/2"AWR UP� I 4 - - N-P/10- -81/4" A CAPPED AT <br /> GENERAT 10 WL �, <br /> UP I EXTERIOR WALL <br /> 1/2"CW UP 32„ q 1 1/2"cCOl 0 CRI c® SAN IC01� ® ® HCW-12 <br /> 3/4" H & CW & 3" SAN UP TO SS CO 03P10 <br /> 2" SAN > r u u ®i I <br /> FET2 14" RWL (OFD) UP FD UP TO r } 1 r L W 12, SEE 1 <br /> TP 12" RWL (OFD) UP (7 NP) b d <br /> b ' ® ® b I 1M129 M501 <br /> 1 2"TP UP STAIR R10 b +j ® ob E 107'-11" ° STAIR R11 <br /> u <br /> — ToA I 1 1 14- - .. . <br /> — R <br /> — — — — — — <br /> O (4) 1/2" FROM TRAP PRIMER 1H <br /> 4" SAN FROM BELOW TRAP PRIMER 14" RWL DIN <br /> MECH ROOM TO FD. 4" SAN DN (4) 1/2" FROM UP AND DN <br /> CAP 6" ABOVE FLOOR IE 107'-7 1/4" TRAP PRIMER <br /> 102P9 O SPILL OFD 1"W TO TOTE 4" SAN UP TO FD & FS. 2 V UP AND DN <br /> 110 <br /> l'-6" ABOVE GRADE 4" SAN FROM FIRE RISERS (R F) <br /> 14" RWL (RD) UP AND DN BELOW CAP <br /> 6" ABOVE FLOOR <br /> 3 5 7 9 <br /> I t <br /> 0.9 11' <br /> B DG 40 O25 <br /> * * * * * N <br /> 1M11011 Mill IIM11211M11311M1141 <br /> PARTIAL FIRST FLOOR PLUMBING PLAN *� - *� * ' N.3 01 <br /> SCALE: 1/8"=l'-0" FINISH FLOOR EL 100'-0° V 1 M 1 1 5 1 M 1 1T61 1 1 7 1 M 1 18 1 M 1 19* * * * N.7 0 <br /> 11M12011M12111M12211M12311M1241 m <br /> P <br /> M125 1M126 1M127 1M128 1M129 <br /> - R <br /> FUTURE BLDG 40-027 <br /> * DENOTES PLANS <br /> NOT INCLUDED <br /> BUILDING 40-026 IN THIS DWG. <br /> KEY PLAN SET <br /> SCALE: NONE N <br /> 8' 4' 0 4' 8' 16' <br /> F#MEERS <br /> REMOVALISSUED FOR CONSTRUCTION <br /> PROFESSIONAL STAMP & SIGNATURE <br /> APPLIES TO WORK WITHIN THE CLOUDED Seattle//Spokane//Baltimore DESIGN BY FSi DATE 03.14.2-L <br /> REVISION AREAS ONLY AS INDICATED <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> MA Cy ACCEPTABILITY RKE 07,17.92 <br /> pp we A� THIS DESIGN AND/OR CHECKED PARTIAL FIRST FLOOR PLUMBING PLAN-REMOVAL W8861360 03.14.24 <br /> RECORD DRAWING ISSUED TO OWNER MGM DJH 06.30.94 E AQUEOUS WASH POS 3— RECORD WBS 252 JAL PSG 12.19.18 1p� SPECIFICATION IS APPROVED RKE 07,17.92 SHEET <br /> A INSTALL DRAIN AND SINK MCS 03.23.00 F 737 NORTH LINE— 40-26 WING TANK CLEANOUT W8861360 FSi KMC 03.14.24 APPROVED By DEPT. DATE RKEN 07.17.92 TITLE 737 NORTH LINE — 40-26 WING TANK CLEAN06T 1 M 129R <br /> BOE//VG CHECKED <br /> B DEMO CHEM CRIB JM 11.22.04 LMM 07.17.92 BUILDING 40-026 APPROVED JOB N0. COMP N0. <br /> C RECORD DRAWING CLEAN—UP J#555672-04 DER GROUP KAP 10.14.05 ss�oxni EHc LMM 07.17.92 <br /> D 787 FA RECORD SET 555886 WH J. MENIKETTI 06.22.07 APPRovED MECHANICAL MASTER COL P—R/9-11 EVERETT, Wq DWI N0. 40-026-1M129R <br />