3003 W CASINO RD 2023 BLDG 40-03 Plans 2026-01-16
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-03
>
Plans
>
3003 W CASINO RD 2023 BLDG 40-03 Plans 2026-01-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/16/2026 9:45:54 AM
Creation date
1/2/2026 1:17:12 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-03
Permit
K2309-014
Year
2023
Notes
BLDG 40-03 RELOCATION OF RACK SYSTEM AND REPLACE 17 HEADS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit# <br /> K230 <br /> 14 <br /> Site 3003 CA GENERAL NOTES: <br /> I oW AMddress: N CASINO ^ZJ 1.THE BOEING EVERETT FIRE NSPECTION DEPARTMENT <br /> Tenant: BOEING /� <br /> (208$55$800)SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL <br /> Hydraulic Information App.' 9/9/2023 \,t�/ VALVE CLOSURES,FLUSHING,AND HYDROSTATIC TESTS ON THE C Permit Type: FIRE SUPPRESSION FIRE PROTECTION SYSTEM.THE MAXIMUM DURATION OF A SYSTEM <br /> RS IFICAArea 1 Suhrype: FIRE SPRINKLER WATER BASED SYSTEM CLOSURE IS 8 HOURS UNLESS PERMISSION IS GRANTED BY THE <br /> OCCUPANCY CLASi1FICATION ESFR Description: BLDG 4GO3 RELOCATION OF RACK SY M <br /> IM II.END HEAD PRESSURE iS.e60(ESFR) FIRE CHIEF. <br /> AND REPLACE 17 HEADS Ts✓ <br /> TOTAL HOSE STREAMS 6M.M �� 2.A CONTRACTOR'S MATERIAL AND TEST CERTIFICATE WILL BE I <br /> A TOTAL HEADS FLOIMWO 4 _- Reviewed S REQUIRED UPON COMPLETION OF THE TESTING.THE CERTIFICATE <br /> /1 K-FACTOR 14 ,Office Set _lab Site Set MUST BE SIGNED OFF BY THE BOEING EVERETT FIRE INSPECTOR <br /> TOTAL WATER REQUIRED SN.72 <br /> DEPARTMENT PRIOR TO COMMENCING ADDITIONAL WORK ON THE <br /> TOTAL PRESSURE REQUIRED 119.214 - FIRE PROTECTION SYSTEM. <br /> SASE of RISER(1 SM.72- 3.PIPE HANGERS SPACING SHALL BE PER NFPA#13. <br /> SASE or RISER(psi) tte.2/4 4.ALL SPRINKLER PIPING 3"AND SMALLER SHALL BE SCHEDULE 40 <br /> SAFETY MAR"(mil +14.M(11.1%) ASTM A-53 GRADE B BLACK STEEL.ALL PIPING 4"AND LARGER <br /> SHALL BE ASTM A-53 SCHEDULE 40 FOR VERTICAL RISERS, <br /> HORIZONTAL MAINS,AND CROSS MAINS. <br /> ._.___ D 5.SPRINKLER SYSTEM PIPE FITTINGS SHALL BE 150 LB.THREADED <br /> SEP 18 2023 MALLEABLE IRON FOR 1-W AND SMALLER,AND VICTAULIC <br /> O TP.O.C. <br /> GROOVED FITTINGS FOR 2-1/2"AND LARGER.PIPE FITTINGS FOR 2" <br /> CITY Oit EVERETTE I TI A E H E - I ET 1MAY BE EITHER 150 LB.THREADED MALLEABLE RON OR VICTAULIC <br /> Permit Services GROOVED. <br /> 8.COUPLINGS FOR GROOVED PIPE AND FITTINGS SHALL BE <br /> 3 VICTAULIC STYLE 07 ZERO-FLEX UNLESS OTHERWISE NOTED. <br /> HYDROSTATIC TEST:PRESSURE-225 PSIG DUFATION-2 HOURS. <br /> o D L -- 10 I 9 8 4 MT 7.SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH <br /> _ O1 102 103 104 - 3 2 6 T �'' (4) FM STANDARDS.SEE FM DATA SHEETS 2-8,"EARTHQUAKE <br /> 1 xV PROTECTION FOR WATER-BASED FIRE PROTECTION SYSTEMS"FOR <br /> I 101 + =. 2% 6 SPECIFIC DETAILS.SPRINKLER DESIGN SHALL EE IN ACCORDANCE <br /> 1_ • • • • • • • • • • Ay • 4 11'-1 WITH THE LATEST VERSIONS OF NFPA 13 AND FIA GLOBAL DATA <br /> _ SHEET 2-0. <br /> 2'/."FIRELOOP m"\+ 8.AUTOMATIC SPRINKLER HEADS SHALL BE 155-165 DEGREE F. <br /> - ��\� 5 i TEMPERATURE RATED. <br /> A 9.ALL EQUIPMENT SHALL BE UL LISTED AND FM APPROVED FOR <br /> 5 — <br /> c 1--11 E 1E r _ IF <br /> FIRE SERVICE. <br /> F F DESIGN CRITERIA: _ <br /> 1.PROVIDE 14K ESFR FIRE SPRINKLER <br /> PROTECTION UNDER THE HORIZONTAL BARRIER TO <br /> PROTECT THE OPEN SHELF DOUBLE AND SINGLE <br /> ROW RACKS,STORING UNCARTONED EXPANDED <br /> PLASTICS UP TO 16 FEET HIGH. <br /> 2.SPRINKLERS SHALL BE LOCATED A MINIMUM OF 3 <br /> 1 ++ FEET ABOVE THE TOP OF STORAGE AT EVERY <br /> I i>I A TRANSVERSE FLUE SPACE,NOT TO EXCEED A <br /> MAXIMUM SPACING OF 8'-0 <br /> NUMBER OF SPRINKLERS CALCULATED:4 <br /> DISCHARGE MINIMUM:50 PSI <br /> I <br /> `1 CONSTRUCTION NOTES <br /> " �SPRINKLER MAIN.MECH <br /> TEE TO ATTACH TO EX STING 8" <br /> I - _ EXISTING FOUR SECTION RACK.40'W X 170"L X I68"H PER RACK, <br /> RELOCATED FROM BUILDING 40.31. <br /> jj If If EXISTING RACK INTERGRATED SPRINKLER HEADS TO BE <br /> REPLACED. <br /> I 4�RACK TO BE LOCATED F-0 MINIMUM FROM FURTHEST POINT OF <br /> I k } SPRINKLER VALVE ASSEMBLY FACE. <br /> r SUPPORT PIPE WITH CLEVIS HANGERS AT 12'O.D.USE 1/2" <br /> THREADED ROD TO SUPPORT CLEVIS HANGERS TO CEILING, <br /> ANCHOR THREADED ROD TO STRUCTURE USINC TOP BEAM CLAMP <br /> OR TRAPEZE STYLE HANGER(SEE DETAILS ON I9524). <br /> W ( w SYMBOL LEGEND <br /> E�EoVE� <br /> MT MECHANICAL TEE <br /> IF fI SEP 09 2023 <br /> W i I W EXISTING SPRINKLER PIPE <br /> J , J NEW SPRINKLER PIPE CITY OF EVERETT <br /> _ -� = Permit Services <br /> H <br /> ! <br /> 6 7 7 8 9 9 D 1 1 12 4 6 t <br /> :v <br /> if <br /> - $ NE�GpTEpkW,1 y E <br /> FIRE P�gRO�N SPRINKI�TEMS 1M260 1M261 1M262 1M263 1M264 D <br /> 9719.0108-C r Level3 D <br /> _._ -.----_.--. _ - - - - - -- - :: .- I Fire Syystems Weal,Inc. <br /> FIRESW1140B7 1M266 iM266 iM267 114266 1M269 S <br /> j IF j If <br /> 8ignatur9 .. 1ti A <br /> -� KEY PLAN <br /> J H LI E EE ;HT - <br /> HANGER LEGEND SPRINKLER HEADS <br /> SYM. TYPE _ SYM. TYPE MFGIMODEL SIN# SIZE TEMP. FINISH CANOPY GTY. <br /> /1e TOP BEAMCLAMP • PENDENT TYCO ESFR-14 TY6236 314" 166-F BRASS N/A 17 S A { Fire Systiams West <br /> FIRE SPRINKLER - PARTIAL FIRST FLOOR PLAN /a PIPE TRAPEZE <br /> /a POWER STRUT ---- _ - -'����__ 206 FRONTAGEPACIFIC, A 98047H,SUITE C <br /> — - - — �� (253)833.1248 FAX:(253)735-0113 <br /> r - TOTAL THIS SHEET 13 DESIGNER:WB FONJOSP-11.12157 DATE:SEPT.1,M22 <br /> SYM REVISION -Y APPROVED DATE SYM RE'JI510N BY AVPROVED DATE ACCEPTABILITY mTu R ;;; Rea L�901,23 <br /> THISDESICNANDroRFIRE PROTECTION R 1211218 AA0 KIP FATIGUE TEST SYSTEM MJP SRZ 10,21.98 �,AV" ® SPECIFICATON IS APPROVEDcr�o _A PRIT/PRAT TOOL RELOCATION SAZAN - 06.22.23 <br /> PRIT/PRAT TOOL RELOCATION 1M2613a <br /> - — --- �o BUILDING 40-003 N <br /> r MECHANICAL MASTER COL C-E/11-13 EVERETT,WA I'I ' 40-03-11111 <br />
The URL can be used to link to this page
Your browser does not support the video tag.