My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11014 19TH AVE SE 2021 O REILLY AUTO 2026-01-06
>
Address Records
>
19TH AVE SE
>
11014
>
O REILLY AUTO
>
11014 19TH AVE SE 2021 O REILLY AUTO 2026-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 9:30:14 AM
Creation date
1/6/2026 9:28:39 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
11014
Tenant Name
O REILLY AUTO
Permit
M2103-119
Year
2021
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NON-POWERED GFCI OUTLET OPERATION CHECK <br /> INSTALLATION INSTRUCTIONS <br /> 1. Turn power ON. Press the RESET button fully on the GFCI <br /> 1. Turn power OFF to unit and power source used to power the outlet. Plug in a GFCI plug tester(also known as a Receptacle <br /> outlet. Tester) into the GFCI outlet. There should be 3 indicator lights <br /> 2. Locate the outlet on your unit. It will be near the control box on the GFCI tester to show the condition of the powered outlet. <br /> area.The wire harness for this outlet will be labeled and located Refer to the GFCI tester indicator lights to ensure correct wiring <br /> within the control box(7.5-12.5 Ton Only). is made. Proceed to Step 2 if it is correct. Proceed to Step 5 if <br /> it is wrong. <br /> 3. Remove gasket and outlet. 2. Next,press the TEST button on the GFCI to trip the device.The <br /> 4. Bring power into the outlet box as shown. Ensure the wiring is GFCI tester should shut OFF and there should be no indicator <br /> suitable for outdoor conditions. Connect the Neutral (white') lights on the GFCI tester. The RESET button will be slightly <br /> wire to the LINE NEUTRAL terminal(Silver). popped-out on the GFCI outlet. To restore power, press the <br /> RESET button on the GFCI. <br /> 5. Connect the 208V/120V(black')wire to the LINE HOT terminal 3. With the power back ON, The GFCI tester should have the <br /> (Brass). indicator lights back ON. Look for a TEST button on the GFCI <br /> 6. Connect a 6-inch bare copper(or GREEN) 12 or 14 AWG wire tester -it is usually located on the top of the tester -and press <br /> to the grounding terminal on the GFCI, and a similar wire to the TEST button on tester. The GFCI will trip and the RESET <br /> the grounding terminal on the box. Connect the ends of these button will slightly pop-out on the GFCI outlet.The GFCI tester <br /> wires to the LINE cable's bare copper(or GREEN)wire using a should show no status or indicator lights;the GFCI is confirmed <br /> wire connector. and passed the GFCI testing.To restore power,press the RESET <br /> button on the GFCI. <br /> 7. Fold the wires into the box,keeping the grounding wire away from 4. If the malfunction indicator light(end-of-life indicator LED)(RED) <br /> the LINE NEUTRAL and HOTterminals. Screw the receptacle lights up, the GFCI has stopped functioning and needs to be <br /> to the box. replaced. <br /> 8. Install cover as per instructions. 5. If the outlet does notwork as described,turn the power OFF and <br /> NOTE: Colors are for wiring color per industry standard. <br /> check the wire connections against the diagram shown above. <br /> Ensure that there are not loose wires or loose connections.If the <br /> RESET button does not work, check the LINE and LOAD con- <br /> nections;they could be reversed.If there are no wiring mistakes, <br /> UNIT ELECTRICAL BOX BLACK the receptacle could be damaged and will need to be replaced. <br /> ° If the connections are rewired to the GFCI, please perform the <br /> ° o ° o Operation Check again. <br /> op o <br /> NOTE: For non-powered outlets that is powered by building power, <br /> e ®� WHITE check power source from building to make sure fuses or breaker <br /> LEAVE YELLOW is not tripped. If the breaker has been tripped, check for shorts in <br /> = o -.... STICKER IN PLACE the wiring. <br /> o , oe TO COVER <br /> ° o ° o o LOAD TERMINALS <br /> Check the TEST and RESET buttons monthly to assure proper <br /> LINE CABLE operation. <br /> BRINGS BACKWIREHOLES SCREWTERMINALS In I <br /> si°e was <br /> POWER "� <br /> TO GFCI <br /> Page 15 of 32 <br />