My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1920 100TH ST SE 2022 Plans 2026-01-12
>
Address Records
>
100TH ST SE
>
1920
>
Plans
>
1920 100TH ST SE 2022 Plans 2026-01-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2026 10:36:07 AM
Creation date
1/12/2026 10:36:01 AM
Metadata
Fields
Template:
Address Document
Street Name
100TH ST SE
Street Number
1920
Permit
M2210-099
Year
2022
Notes
MODIFY EXISTING DUCT SYSTEM, ADD EXH FAN, DUCTWORK
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: M22 LO-099 <br /> Site Address: 192C 100TH ST SE BLDG A <br /> SubjectTo Field Inspection Owner. SEA-MAR COMMUNITY HEALTH CENTER <br /> Tenant SEA MAR COMMUNITY HEALTH CENTERS <br /> HVAC ABBREVIATIONS HVAC LEGEND HVAC NOTES App P,,tp te: 10/16/2022 <br /> Proposed Use:COMMERCIAL MECHANICAL(PLAN REVIEW <br /> REQUIRED) <br /> AFF ABOVE FINISHED FLOOR 1. DUCT INSULATION TO NzET THE REQUIREMENTS OF SECT- De—peon: MODIFY EXISTING DUCT SYSTEM,ADD <br /> BOO BACKDRAFT DAMPER 0 INL NE EXHAUST FANS O ION C403.10 OF THE 20',8 WSEC AND SECTION 604 OF EXH1 WSr FAN,DUCTWORK FOR NEW <br /> BTUH BRITISH THERMAL UNIT PER HOUR GR PLA <br /> CD CEILING DIFFUSER THE IECC(INTERNATIONAL ENERGY CONSERVATION CODE). Reviewed By <br /> ��Lt Date: o .s Z�ZL <br /> CFM CUBIC FEET PER MINUTE ROOFTOP EXHAUST FAN 2. SMOKE DETECTOR(S)INSTALLED IN MAIN RETURN AIR Dm_e set ;N1_iob Site Set _Fire/Planningset <br /> CU CONDENSING UNIT 0 DUCTS PER SECTION 606 OF THE 2018 IMC.HVAC SMOKE <br /> DB DECIBEL DUCT DETECTORS SHALL SHUT DOWN POWER TO THE <br /> DH DUCT HEATER UNIT UPON ACTIVATION AND A"SUPERVISORY"ZONE SHALL THIS SET OF <br /> DOAS DEDICATED OUTSIDE AIR SYSTEM SIDEWALL EXHAUST FAN BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT R HAL <br /> ON DOWN BE ON J <br /> EC EVAPORATOR COIL DETECTOR ACTIVATION.2018 IMC SECTION 606.4&604.6.1. <br /> EER ENERGY EFFICIENCY RATIO 3. SUPPLY&RETURN AIR DUCT IS MIN.OUTSIDE <br /> UNCONDITIONED U ^V \y/ M1 <br /> EF EXHAUST FAN VAV FAN BOX SPACES&MIN.R-8 WHEN LOCATED OUTSIDE OF BUILDING u�J 1J �/ nu u <br /> EG EXHAUST GRILLE AS PER THE 2018 WSEC C403.10.1.2. �10�0��W ��EOM <br /> ERV ENERGY RECOVERY VENTILATOR 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED uuuul uuuu uu JU <br /> ESP EXTERNAL STATIC PRESSURE CEILING EXHAUST FAN WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION AIR CONDITIONING-HEAT PUMPS-REFRIGERATION- <br /> EXH EXHAUST <br /> FCU FAN COIL UNIT INSTRUCTIONS PER 2018 IMC,SECTION 403 AND SHALL CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF <br /> OPERATE PER 2018 WSEC,SECTION C403.5.1. AUBURN: (253)939-5501 TACOMA <br /> FD FIRE DAMPER,FLOOR DRAIN O GAS METER (253)922-3141 <br /> SEATTLE: (253)839-212E FAX: (253)735-3432432 <br /> FPM FEET PER MINUTE 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE <br /> FSD FIRE AND SMOKE DAMPER ZD12 FOR INSPECTIONS. P.O.BOX ERSAL AFRIGERUB 70NWAS DRAWIN-201 <br /> GA GAUGE VVi DAMPER ©UNNERSAL REFRIGERATION DRAWING-2001 <br /> GF GAS FURNACE 6. ALL HVAC EQMT.TO BE LABELED TO THE SPACE SERVED. <br /> GRD GRILLE,REGISTER,DIFFUSER 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE z <br /> HP HORSEPOWER,HEAT PUMP T THERMOSTAT VERTICAL AT 124,MAX.,HORIZONTAL AT 10'-0"MAX. O <br /> ID INSIDE DIMENSION WITH STRAP,OR 8'-0"MAX.TRAPEZE SUPPORT. L <br /> IHP INDOOR(SECTION)HEAT PUMP n- <br /> IRH INFRARED HEATER B. THERMOSTAT TO BE SEVEN-DAYTYPE AND HAVE NIGHT <br /> KW KILOWATT T-BAR SUPPLY DIFFUSER SETBACK WITH 5 DEGREE DEADBAND. U <br /> M <br /> MCD MOTORIZED CONTROL DAMPER THOUSAND BTU PER HOUR FE <br /> 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL LU <br /> 0 <br /> NC NOISE CRITERIA CD SECTIONS OF 2018 WSEC C408 HAVE BEEN SATISFIED.THIS <br /> NIC NOT IN CONTRACT ❑ T-BAR RETURN GRILLE SHALL INCLUDE AS-BUILT DRAWINGS,SUBMITTALS,0&M O D <br /> MANUALS,SYSTEM BALANCE REPORT,AND A COMMIS-NOT TO SCALE cn <br /> OBD OPPOSED BLADE DAMPER SIONING REPORT. �j <br /> OC ON CENTER Z HARDLID SUPPLY DIFFUSER 10.DUCT SEALING SHALL MEET REQUIREMENTS OF 2018 WSEC LLI <br /> OD OUTSIDE DIMENSION OR DIAMETER <br /> C403.10.2. DUCT WORK WHICH IS DESIGNATED TO w <br /> OHP OUTDOOR HEAT PUMP OPERATE AT PRESSURES ABOVE 1/2"WATER COLUMN a <br /> OSA OUTSIDE AIR HARDLID RETURN GRILLE <br /> STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: <br /> OSCI OWNER SUPPLIED CONTR.INSTALLED LU FD �— FIRE DAMPER � I <br /> POC POINT OF CONNECTION 1. STATIC PRESSURE 1/2INCH TO 2INCHES:SEAL ALL <br /> RA RETURN AIR TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. p p <br /> RAG RETURN AIR GRILLE SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT <br /> RPM REVOLUTIONS PER MINUTE FSD FIRE SMOKE DAMPER WORK DO NOT REQUIRE SEALING;HOWEVER,OTHER ; <br /> RTU ROOFTOP UNIT SEAMS SHALL BE SEALED. DJ <br /> SA SUPPLY AIR VOLUME DAMPER 11.2018 WSEC FORMS,DUCT PLANS,BALANCING FEATURES, cc <br /> SG SUPPLY GRILLE AS WELL AS VENTILATION REQUIREMENTS(AS PER TABLE <br /> SP STATIC PRESSURE 403.3.1.1,2018 IMC MINIMUM VENTILATION RATES)AND <br /> SSG SIDEWALL SUPPLY GRILLE SD SMOKE DETECTOR OCCUPANCY,ALONG WITH A MECHANICAL PERMIT AT THE <br /> TBD TO BE DETERMINED TIME OF THE TENANT IMPROVEMENT PERMIT. CID <br /> TG TRANSFER GRILLE FLEXIBLE DUCT SA RA <br /> TYP TYPICAL O <br /> UH UNIT HEATER ® IN <br /> VFD VARIABLE FREQUENCY DRIVE ROUND DUCT UP SCOPE OF WORK VTR VENT TO ROOF <br /> VVT VARIABLE VOLUME AND TEMPERATURE JOB# 22X)OC LU <br /> O ROUND DUCT DOWN 1. INSTALL(1)EXHAUST FAN W./ASSOC.VENTING. r Q <br /> 10x10 CD 2. MODIFY EXISTING DUCT DISTRIBUTION SYSTEM TO BEST L� <br /> 1 CFM-CD DIFFUSER TAG ACCOMMODATE NEW TENANT IMPROVEMENT FLOORPLAN. <br /> 3. INSTALL DUCTWORK,GRILLES®ISTERS. L u <br /> _J �� LL <br /> APPROVED �..1 W OI6d CommuNp•,Planning 6 Eeonomfc Dewbpngnt � <br /> PLANNING DEPARTMENT 1 <br /> NNI DATE:I o z (�j W <br /> l o a: w <br /> a < <br /> �'- � <br /> E'er T_ <br /> Additional Permits Are Required C;� O <br /> For This Project To Include: `` r <br /> aAfrr a /5 4✓�EPE�DC✓f UeQr SuoP6�r ❑ Plumbing ❑Sprinkler L� <br /> �LAf /tYL4Cry 4 PE/L QScF /6 tr L/r Mechanical Fire Alarm �il <br /> Electrical r n � <br /> EXCE6ps ZD LBS. ") <br /> T <br /> PRINT/PLOT D>TE: <br /> FAN SCHEDULE <br /> DRAFTER: <br /> �'ID BRAND NAME MODEL NUMBER CFM SP HP/AMP FLOW WPH SOUND DUCT LOCATION ARW <br /> RATING <br /> DESIGNER: <br /> EF-1 NUTONE QTXEN150 150 .10 .5 A CV 120/1 1.4 SON ES 6"0 I.T.ROOM SS <br /> PROJECT MANAGER: <br /> SS <br /> JOB NUMBER: <br /> :'iTY CJF EyERETT 22xxx <br /> REVIEWED FOR PERMIT SHEET NUMBER: <br /> M-C <br /> PENDING CITY APPROV/ L_ <br /> NOTE:These plans are diagrammatical only. <br /> Please verify all dimensions at job site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.