My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Earthwork Solutions, LLC 1/14/2026
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Earthwork Solutions, LLC 1/14/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 2:09:51 PM
Creation date
1/14/2026 2:01:24 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Earthwork Solutions, LLC
Approval Date
1/14/2026
Council Approval Date
1/7/2026
Department
Public Works
Department Project Manager
Laura Claywell
Subject / Project Title
RRFB PEDESTRIAN SAFETY
Tracking Number
0005072
Total Compensation
$715,108.86
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
RRFB PEDESTRIAN SAFETY October 31, 2025 <br />STATE FUND # HLP-PB25(004) <br />WO 3807 <br />Page 65 of 82 <br />1 One long life photocell compatible with the seven pin (PCR7) receptacle shall be provided for <br />2 each service cabinet. The following photocells are pre-approved for use: <br />3 <br />4 Ripley Lighting Controls Long Life II 6390LL-BK-2.8 <br />5 Sun-Tech TRS-2-8190 <br />6 Dark to Light DLL Elite 127-2.8 IR <br />7 <br />8 The LED nominal correlated color temperature shall be 4000”K +/- 200”K with a CRI ≥ 70. The <br />9 light emitting diodes shall be high flux, high power white LED producing a minimum of 90% of <br />10 initial intensity at 70,000 hours of life. The LEDs shall provide a copy of their test documentation <br />11 to the Engineer for the IES LM-80 testing procedure. The LEDs shall be mercury and lead free. <br />12 Nominal lumen efficacy shall exceed 108 lumens/W. <br />13 <br />14 Individual micro-lens optics shall produce IES Type 2 or Type 3 full cutoff distributions with 0% <br />15 lumens above 90” nadir. The power supply shall have less than 20% total harmonic distortion <br />16 and a minimum power factor of 0.90. The EMC shall meet or exceed FCC CFR Part 15. <br />17 Transient voltages shall comply with ANSI C62.41 Cat. A. An integral surge protector shall <br />18 meet ANSI/IEEE C62.45, C62.41.2, IEC61000-4-2, and IEC 61000-4-4. Each luminaire shall <br />19 be provided with a standard 3 x 3 ANSI label indicating the wattage and the light source type <br />20 (LED), using black letters on a reflective white background. <br />21 <br />22 The finish shall be a fade and abrasion resistant, epoxy polyester powder coat with a light gray <br />23 color. The luminaire shall meet UL listing for wet locations and maintain an IP66 rating for the <br />24 optics compartment and an IP54 rating or better for the power compartment. <br />25 <br />26 The Street Luminaires shall meet or exceed the following initial delivered lumen output: <br />27 <br />28 <br />29 Large Luminaire (400W HPS relative equivalent): <br />30 Type 3 distribution:≥ 18,000 lumens <br />31 <br />32 The following listed fixtures meet the required specifications: <br />33 <br />34 <br />35 Large Luminaire: <br />36 <br />37 Type 3 distribution: <br />38 Leotek GCM3-60J-MV-40K-3R-GY-185-PCR7-4B-RWG-WL-BSK <br />39 Schreder SMART3-US-48L185-NW-T3M-SV-GY-D01-AA-AB <br />40 LED Roadway NXT-72M-5-7-3LB-7-GY-3-UL-X-4H-BIRD <br />41 <br />42 CNH 8-20.4 MEASUREMENT.RTF <br />43 8-20.4 Measurement <br />44 The first sentence of Section 8-20.4 is revised to read: <br />45 <br />46 No specific unit of measurement will apply to the lump sum items for illumination system, <br />47 intelligent transportation system (ITS), or traffic signal systems, but measurement will be <br />48 for the sum total of all items for a complete system to be furnished and installed. <br />49 <br />50
The URL can be used to link to this page
Your browser does not support the video tag.