My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Earthwork Solutions, LLC 1/14/2026
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
Earthwork Solutions, LLC 1/14/2026
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 2:09:51 PM
Creation date
1/14/2026 2:01:24 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Earthwork Solutions, LLC
Approval Date
1/14/2026
Council Approval Date
1/7/2026
Department
Public Works
Department Project Manager
Laura Claywell
Subject / Project Title
RRFB PEDESTRIAN SAFETY
Tracking Number
0005072
Total Compensation
$715,108.86
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
RRFB PEDESTRIAN SAFETY October 31, 2025 <br />STATE FUND # HLP-PB25(004) <br />WO 3807 <br />Page 71 of 82 <br />Category 2: Sensitive information <br />1 <br />2 <br />3 DIVISION9.GR9 <br />4 Division 9 <br />5 Materials <br />6 <br />7 KEL 9-29.1 CONDUIT.RTF <br />8 9-29.1 Conduit, Innerduct, and Outerduct <br />9 Section 9-29.1 is supplemented with the following: <br />10 <br />11 Pull String <br />12 All conduit shown in the plans, proposed and existing conduit to receive conductors, <br />13 and conduit installed for future use, shall have flat woven polyester tape installed and <br />14 secured at either end of the run. Tape shall be detectable, ‰ minimum width and <br />15 printed with sequential footage markings. Pull strength shall be 900lbs minimum. <br />16 <br />17 Conduit Sealing <br />18 Mechanical plugs for cabinet conduit sealing shall be one of the following: <br />19 <br />20 1. Tyco Electronics - TDUX <br />21 2. Jackmoon Triplex Duct Plugs <br />22 3. O-Z Gedney Conduit Sealing Bushings <br />23 <br />24 The mechanical plug shall withstand a minimum of 5 psi of pressure. <br />25 <br />26 9-29.1(2) Rigid Metal Conduit Fittings and Appurtenances <br />27 Section 9-29.1(2) is supplemented with the following: <br />28 <br />29 Conduit Coatings <br />30 Electroplated couplings are not allowed. <br />31 <br />32 Surface Mounting Conduit Attachment Components <br />33 Channel supports and all fastening hardware components shall be Type 304 <br />34 stainless steel. Conduit clamps shall be one piece, two bolt units with lock <br />35 washers. <br />36 <br />37 9-29.1(4) Non-Metallic Conduit <br />38 Section 9-29.1(4) is supplemented with the following: <br />39 <br />40 PVC conduit shall be either Schedule 40 or Schedule 80, as indicated on the plans. <br />41 Schedule 80 shall be required for all street crossings and for the bottom 10’ of pole <br />42 risers. Schedule 80 shall be used for all conduits that are installed using Directional <br />43 Bore method. Bell end bushings shall be installed on all conduit ends. Conduit runs, <br />44 without innerduct, installed using directional boring method shall be Schedule 80 high <br />45 density polyethylene (HDPE) if the runs enter/cross the traveled way or shoulder, and <br />46 Schedule 40 HPDE for runs that do not enter or cross the traveled way or shoulder. <br />47 <br />48 CNH 8-20.2(9-29.2) Junction Box.RTF <br />49
The URL can be used to link to this page
Your browser does not support the video tag.