2727 MAPLE ST 2025 Plans 2026-04-09
>
Address Records
>
MAPLE ST
>
2727
>
Plans
>
2727 MAPLE ST 2025 Plans 2026-04-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2026 11:26:47 AM
Creation date
4/9/2026 11:26:44 AM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2727
Permit
FA2504-013
Year
2025
Notes
Replacement of two failed silent knight NAC power supplies.
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2504-013 <br /> Site Address: 2727 Maple St <br /> Everett Storage Depot Description: <br /> Date Replacement <br /> Alarm Inc:(ELEC) � t ADescription: Replacement oftwo falent <br /> kni General notes: <br /> ght NAC power supplies. _ <br /> Review Date: 04/23/2025 y <br /> 1.Scope of work:This project includes the consolidation and replacement of tw <br /> Fire Alarm System failed Silent Knight NAC power supplies into one Potter NAC power supply. 3 gNNN`�� <br /> Field load calcualtions will need to be done in order to verify operations. <br /> v <br /> EVERETT <br /> Everett Fire Dept.Permit Review 2.These drawings are diagrammatic.Refer to the architectural drawings for <br /> Status:Approved exact dimensions. <br /> Reviewed By:KBrown <br /> 04/23/2025 3 52:39 3.Installation shall comply with NEC,NFPA 72 and all other applicable codes as <br /> PM required by the local authority having jurisdiction. <br /> i <br /> 4.Wiring depicted on these plans is schematic,actual wire locations may differ <br /> from these plans.Wiring shall be performed as actual building construction <br /> ( r ; conditions allow and to minimize penetrations through area separation walls Q <br /> and fire rated walls.The use of a raceway is permitted as long as no 110 V or <br /> '^ ° higher voltage cables are in the same raceway. Z o <br /> O5.Final ratings shall be maintained for all penetrations through fire rated <br /> { \' construction. <br /> 8'Power for all fire alarm panels and fire alarm power supplies must be provided 4 <br /> by a dedicated AC branch circuit.The location of the branch circuit breaker <br /> shall be permanently identified at the control unit. Where a circuit breaker is a <br /> the disconnecting means,an approved breaker locking device shall be installed. <br /> a For fire alarm and/or signaling systems,the circuit disconnecting means shall N <br /> • have a red marking. <br /> + c s 7.Power limited in non-power limited circuit wiring must remain separated in N <br /> cabinet.All power limited circuit wiring must remain at least a quarter inch a <br /> Existing Power Supply away from any non-power limited circuit wiring.Furthermore,all power limited o <br /> Vacinity Map "ill and non-power limited circuit wiring must enter and exit the cabinet through <br /> different knockouts and or separate conduits. <br /> I B.When utilizing class A circuits,separate outgoing and return conductors of <br /> oto1O1cuX class a circuits by a minimum of 12 inches were run vertically and 48 inches m <br /> were run horizontally. <br /> El El <br /> 9.AII fire alarm cabling shall be acceptable to the fire alarm equipment <br /> manufacturer for the intended purpose. a <br /> 10.Smoke detector shall not be installed until after construction cleanup is <br /> completed and final. <br /> Jesse Houfek,SE T140509 <br /> 11.1-ocate smoke detectors a minimum of 3 feet from mechanical supplies. <br /> epsl Wall-mounted smoke detectors shall be located a minimum of 4 inches and a Fireaann yatema,Level Iv <br /> maximum of 12 inches from ceilings. <br /> is- <br /> REVISION 1: <br /> p 12.Provide synchronization of all visual notification appliance circuits. Review <br /> /\ 13.Upon completion of the fire alarm system installation and programming,the 04/22/25 <br /> •- Q installing contractor shall perform final testing of the entire system,per all REVISION 2: <br /> P P applicable codes,and shall coordinate and perform a final fire alarm system <br /> /\ /\ / / /\ / ,slca / .�..n❑O�. o .®®ems inspection. <br /> p P ,rvacs �Jv� <br /> 14.Provide off site monitoring as required by the international fire code,section REVISION 3: <br /> ❑oo❑ _ ,0. ;o; ;o, \ \ 907.6.6 and the local authority having jurisdiction. <br /> _ ;O; b; \ ;O ;O; a.un,q <br /> � E]1-1 � "'" "plral 15.Installing contractors show physically label all initiating devices and <br /> notification appliance circuit and of lines(when wiring class B).These labels <br /> shall be in place prior to start up in testing. <br /> PSN-106 <br /> SPS2 "Cr 0 <br /> Q <br /> (D o <br /> N <br /> Fire Alarm Riser L <br /> 00 d <br /> CD <br /> (Typical) Power Supply Wiring < Ijn <br /> SYSTEM OUTPUTS <br /> (Typical) Required Fire Safety Control <br /> Control Unit Annunciation <br /> 0) <br /> L ILL! <br /> & O H <br /> £m g <br /> .M Symbol Legend A Any ya p sr q 2 W cr14 <br /> SYMBOL DESCRIPTION MANUFACTURER PART NUMBER QUANTITY <br /> o ra a <br /> P31.1 6AMP,120VAC POWER SUPPLY(Existing) SILENT KNIGHT SK4'S6 1 � , 1 1 I <br /> P52. NAC POWER SUPPLY I0 AMPS OUTPUT POTTER ELECTRIC SIGNAL PSN-106 1 r r r <br /> STROBE,MC,WHITE,WALL(Example Only) POTTER ELECTRIC SIGNAL S-24W W 18 <br /> SYSTEM INPUTS A B C D E F G H I J K L M N O <br /> ♦♦ ♦♦♦♦ ♦♦ 1 <br /> MORN/STROBE,2 WIRE,MC 1 Manual Fire Alarm Boxes,WXITE,WALL(Example Only) POTTER ELECTRIC SIGNAL MS-24WW 24 2 Smoke Detectors ♦♦ ♦♦♦♦ ♦♦ 2 DESIGNED BY: <br /> Imo„ Poue6 EOL,5.1K Ohms POTTER ELECTRIC SIGNAL EOL3.1 6 3 Heat Detectors ♦♦ ♦♦♦♦ ♦♦ 3 JH <br /> 4 Waterflow ♦♦ ♦♦♦♦ ♦♦♦4 <br /> Mounting Equipment Elevations 5 IN-Duct Smoke Detectors ♦♦ ♦ 5 <br /> 6 Sprinkler Control Valve ♦♦ ♦ 6 <br /> (Typical) 7 Fire Alarm AC Power Failure ♦♦ ♦ 7 DATE: <br /> 8 Fire Alarm System Low Battery ♦♦ ♦ 8 <br /> 8 1 Open Circuit ♦♦ ♦ 8 04/22/25 <br /> 10 Ground Fault ♦♦ ♦ 10 <br /> 11 Notification Appliance Circuit Short ♦♦ ♦ 11 <br /> A B C D E F G H I J K I L M I N 10 1 JOB NUMBER: <br /> A Fire Alarm Title Sheet <br /> 27155-1 <br /> Opperational Matrix <br /> (Typical) SHEET NUMBER: <br /> FA-1 .0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.