My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5301 SOUND AVE 2025 Plans 2026-04-10
>
Address Records
>
SOUND AVE
>
5301
>
Plans
>
5301 SOUND AVE 2025 Plans 2026-04-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2026 11:06:33 AM
Creation date
4/10/2026 11:06:20 AM
Metadata
Fields
Template:
Address Document
Street Name
SOUND AVE
Street Number
5301
Permit
B2506-119
Year
2025
Notes
replace existing rear deck on 2ND STORY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Everett Permit Services <br /> EVERETT Reviewed for Permit 07/10/2025 <br /> WASHINGTON 11 <br /> O <br /> N <br /> 00 <br /> PROJECT SUMMARY � <br /> r <br /> 2 <br /> THE PROJECT INVOLVES DEMOLISHING THE i <br /> u NON-CONFORMING WRAP-AROUND PATHWAY DECK, (n > <br /> i REPLACING THE MAIN 18'X12' DECK WITH A NEW 7 <br /> PRESSURE-TREATED WOOD STRUCTURE FEATURING O W LLI <br /> '` <br /> ' AND GLASS <br /> RAILING,P' Ix ' UPGRADING POSTS AND FOUNDATIONS TO SUPPORT p 0 Q <br /> A SECOND-STORY DECK. Q <br /> O C <br /> U <br /> 7 <br /> C 0 � <br /> PROJECT INFORMATION � v � M <br /> s Oo aLo <br /> >ys ` OWNER: Vf <br /> DANTONIO MARYLOU 0 <br /> PROJECT ADDRESS: <br /> /C\ \ 5301 SOUND AVE, EVERETT, WA 98203 <br /> C N <br /> O <br /> GENERAL NOTES 0 a •� <br /> cao �n <br /> • CODE COMPLIANCE <br /> N M <br /> ALL WORK SHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE (IRG), INTERNATIONAL BUILDING CODE • DECK ATTACHMENT SUPPORT <br /> (IBC), WASHINGTON STATE BUILDING CODE (WSBC), AND ALL APPLICABLE LOCAL REGULATIONS. ALL STRUCTURAL CONNECTIONS SHALL BE INSTALLED PER APPLICABLE CODES AND MANUFACTURER <br /> WHERE CONFLICTS ARISE BETWEEN CODES, THE MOST STRINGENT REQUIREMENT SHALL APPLY. GUIDELINES. <br /> THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK MEETS OR EXCEEDS THE MINIMUM LEGAL THE CONTRACTOR IS RESPONSIBLE FOR ENSURING PROPER ANCHORING OF STRUCTURAL COMPONENTS USING a a a a <br /> REQUIREMENTS. APPROVED FASTENERS AND BRACKETS. <br /> IF CONDITIONS ARISE THAT REQUIRE MODIFICATIONS, THE CONTRACTOR MUST OBTAIN WRITTEN APPROVAL <br /> • SITE INSPECTION f VERIFICATION BEFORE MAKING CHANCES. <br /> THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS PRIOR TO CONSTRUCTION. u >M <br /> ANY DISCREPANCIES, UNFORESEEN CONDITIONS, OR CONFLICTS BETWEEN PLANS AND ACTUAL SITE CONDITIONS CONTRACTOR DISCRETION I JUSTIFICATION 0) <br /> MUST BE REPORTED BEFORE PROCEEDING. THE CONTRACTOR MAY MAKE FIELD ADJUSTMENTS AND MODIFICATIONS, PROVIDED THEY: 0 C O (D <br /> THE CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND UNDERSTANDING ALL PROJECT DOCUMENTS AND SITE COMPLY WITH ALL APPLICABLE CODES, REGULATIONS, AND INDUSTRY STANDARDS. z � <br /> CONDITIONS. DO NOT COMPROMISE STRUCTURAL INTEGRITY OR PROJECT INTENT. <br /> ARE JUSTIFIABLE BASED ON SITE CONDITIONS OR PRACTICAL CONSIDERATIONS. V u <br /> • WORKMANSHIP f STANDARDS IF REQUESTED, THE CONTRACTOR MUST PROVIDE JUSTIFICATION FOR ANY DEVIATIONS FROM THE DRAWINGS. W <br /> ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER, CONSISTENT WITH INDUSTRY STANDARDS AND ANY MAJOR DEVIATIONS OR MODIFICATIONS MUST BE DOCUMENTED AND REPORTED TO THE OWNER OR <br /> BEST PRACTICES. ARCHITECT. u <br /> THE CONTRACTOR SHALL ENSURE THAT ALL MATERIALS USED MEET OR EXCEED APPLICABLE CODES ANDuj <br /> MANUFACTURER RECOMMENDATIONS. INSPECTION I APPROVAL � IQ <br /> ANY PROPOSED SUBSTITUTIONS OR DEVIATIONS MUST BE APPROVED IN WRITING BEFORE IMPLEMENTATION. THE CONTRACTOR SHALL SCHEDULE AND PASS ALL REQUIRED INSPECTIONS B WORK OR COVERING ANY WOR OR Q � <br /> PROCEEDING TO THE NEXT PHASE OF CONSTRUCTION. <br /> • STRUCTURAL REQUIREMENTS THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH INSPECTORS TO ENSURE COMPLIANCE WITH ALL LLI <br /> ALL STRUCTURAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH PRESCRIPTIVE SPAN TABLES OR APPLICABLE CODES. J •� <br /> AN APPROVED ENGINEERED DESIGN. ANY MODIFICATIONS REQUIRED BY INSPECTORS SHALL BE COMPLETED IN ACCORDANCE WITH THEIR DIRECTION <br /> FOOTINGS SHALL BE SIZED AND INSTALLED PER LOCAL DEPTH AND LOAD REQUIREMENTS. AT THE CONTRACTOR'S EXPENSE. <br /> DECK FRAMING SHALL BE CONSTRUCTED USING APPROVED MATERIALS SUITABLE FOR OUTDOOR USE, SUCH AS <br /> PRESSURE-TREATED WOOD OR CERTIFIED STEEL (OR OTHER) FRAMING SYSTEMS. SITE CLEANUP I SAFETY <br /> ALL FASTENERS, CONNECTORS, AND HARDWARE SHALL BE CORROSION-RESISTANT AND COMPATIBLE WITH THE THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A GLEAN AND SAFE JOB SITE AT ALL TIMES. designed by IP ,DESIGN <br /> MATERIALS USED. ALL WASTE MATERIALS SHALL BE DISPOSED OF IN COMPLIANCE WITH LOCAL REGULATIONS. ilia@ipdesign.group <br /> THE CONTRACTOR SHALL IMPLEMENT NECESSARY SAFETY MEASURES TO PROTECT WORKERS, PROPERTY, AND <br /> THE PUBLIC DURING CONSTRUCTION. Page 1/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.