My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2000 TOWER ST 2025 PARKS STUDENT UNION Plans 2026-04-10 (2)
>
Address Records
>
TOWER ST
>
2000
>
PARKS STUDENT UNION
>
Plans
>
2000 TOWER ST 2025 PARKS STUDENT UNION Plans 2026-04-10 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2026 11:29:56 AM
Creation date
4/10/2026 11:29:55 AM
Metadata
Fields
Template:
Address Document
Street Name
TOWER ST
Street Number
2000
Tenant Name
PARKS STUDENT UNION
Permit
E2501-246
Year
2025
Notes
1ST FLOOR STUDENT UNION BLDG, Controls, Lighting Upgrades
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d� <br /> �o <br /> N <br /> o L� C7 Cb <br /> £- c O O <br /> Z E V) N CV <br /> ua ® CU N <br /> w � CT <br /> M <br /> o� j, C-4 <br /> U) N N•� co0c)ca � <br /> LJJ C71 <br /> v <br /> w; 1Vo �. =o <br /> N � <br /> cn <br /> TYPICAL GENERAL DEMOLITION NOTES(APPLIES TO ALL DEMOLITION DRAWINGS) 1 J :L N v <br /> ELECTRICAL LEGEND <br /> 1. THESE PLANS DELINEATE THE BASIC SCOPE OF WORK FOR THE REMOVAL OF EXISTING MATERIAL.THE SYMBOL DESCRIPTION SYMBOL DESCRIPTION I 0 c, j N <br /> DEMOLITION <br /> LIMI SOFWORK.T/ECO TRACTORSHALINGS AND NOTES ARE RBE AMIILAOVIDED IRWITH HETH THE ESTEANDCO DITONSNT TO GENERALLY SHEIREON;BE ANDSHALL IS ONTI]HO �lAlOTCHEB S ANDQ L� ~ <br /> NOT RELY SOLELY ON REVIEW OF THE BIDDING DOCUMENTS IN DETERMINING THE EXTENT OF DEMOLITION <br /> WORK REQUIRED.COORDINATION OF THESE DRAWINGS WITH REQUIREMENTS FOR CONTRACT WORK IS THE 7_1 RECESSED LIGHT FIXTURE $ SINGLE POLE SWITCH <br /> RESPONSIBILITY OF THE CONTRACTOR.DISCREPANCIES BETWEEN OR WITHIN THE CONTRACT DOCUMENTS y,.BIT <br /> SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.THE CONTRACTOR SHALL PROVIDE CLARITY SKETCHES, O SURFACE OR PENDANT MOUNT LIGHT FIXTURE(CIRCLE INDICATES RECESSED OR CONCEALED JUNCTION BOX) $LV4 LOW VOLTAGE 4 BUTTON DIMMING SWITCH 4 g of WAgg if <br /> DIAGRAMS,AND FIELD DIMENSIONS OF EXISTING CONDITIONS AT THE REQUEST OF THE ENGINEER IFIWHEN CONFLICTS ARE IDENTIFIED. 11 SURFACE OR RECESSED LIGHT FIXTURE El CEILING MOUNTED OCCUPANCY SENSOR LIGHTING CONTROL) G' <br /> 2. REMOVE ALL WIRES,CABLES,SURFACE MOUNT RACEWAYS AND ALL APPURTENANCES WHICH SERVE DEVICES O SURFACE OR RECESSED LIGHT FIXTURE VS CEILING MOUNTED OCCUPANCY SENSOR(LIGHTING CONTROL) <br /> �f <br /> BEING REMOVED.CUT CONDUIT FLUSH TO CEILING OR WALL WHEN CONCEALED,AND SEAL OFF WITH SPRAY ® EXIT LIGHT FIXTURE(PROVIDE DIRECTION ARROWS AS INDICATED)PROVIDE ADDITIONAL UNSWITCHED HOT LEG. nn �a��n n n nn O n n�a 'osa�ts $o�1 <br /> FOAM.ABANDON FLUSH BOXES AND NON-ACCESSIBLE CONDUIT,PROVIDE COVER PLATES FOR ALL BOXES TO EMERGENCY BATTERY PACK WITH TWIN HEAD FLOOD PROVIDE ADDITIONAL UNSWITCHED HOT LEG.(E INDICATES EXISTING TO IIW U LL Ln H V U SIONAL <br /> REMAIN.CUT CONDUIT FLUSH TO FLOOR AND SEAL WITH GROUT. E BE RETAINED) <br /> Oi CONSTRUCTION NOTES 1-/27/2025 <br /> 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR ALL CUTTING,PATCHING AND COMBINATION EXITITWIN HEAD FLOOD(PROVIDE DIRECTION ARROWS AS INDICATED)PROVIDE ADDITIONAL FINISH WORK. O0o E UNSWITCHE REUSE OF DOCUMENTS <br /> D HOT LEG.(E INDICATES EXISTING TO BE RETAINED) O DEMOLITION NOTES THE DRAWINGS AND SPECIFICATIONS CONTAINED <br /> HEREIN ARE THE PROPRIETARY,UNPUBLISHED <br /> W W INDICATES WEATHERPROOF FOR ALL DEVICES,PROVIDE LOCKING COVER ON RECEPTACLES. PROPERTY OF BCE ENGINEERS AND SHALL NOT <br /> 4. UNLESS NOTED OTHERWISE DISCONNECT AND REMOVE ALL DEVICES INDICATED.MAINTAIN CONTINUITY OF ALL D BE REPRODUCED,COPIED,OR DISCLOSED IN <br /> EC <br /> REMAINING DEVICES&EQUIPMENT.PROVIDE JUNCTION BOXES,CONDUIT AND WIRE TO EXTEND EXISTING R EPTAC LES �� WHOLE OR PART WITHOUT THE WRITTEN <br /> CIRCUITS AS REQUIRED. ALL DEVICES WITH LIGHT LINE WEIGHT INDICATES EXISTING TO BE RETAINED PERMISSION OF BCE ENGINEERS. <br /> DUPLEX RECEPTACLE(E INDICATES EXISTING) <br /> __„';; ALL DEVICES WITH DASH LINE INDICATES EXISTING TO BE REMOVED <br /> FOURPLEX COMBINATION UNSWITCHED DUPLEX RECEPTACLE AND CONTROLLED(SWITCHED)GREEN DUPLEX RECEPTACLE <br /> TYPICAL ELECTRICAL GENERAL NOTES(APPLIES TO ALL DRAWINGS) IEQUOPNIE T AA,WOROM H DD RACEWAYS HIETWOR W H I QSTRUCTUR Z <br /> 1. MATERIALS AND WORKMANSHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST <br /> �� CONDUIT STUB OUT(PROVIDE CONCRETE MARKER ON EXTERIOR) COMMUNICATION/DATA OUTLET-WALL MOUNT WITH(2)DATA PORTS AND(2)CAT6 CABLES(4/S BOX WITH SINGLE GANG <br /> EDITION OF THE NATIONAL ELECTRICAL CODE(NFPA 70),WASHINGTON STATE MUDRING AND COVER PLATE)ANDS TO ACCESSIBLE CEILING SPACE,MOUNT INDICATES <br /> AFF UNLESS NOTED OTHERWISE.(A ZD <br /> ADMINISTRATION CODE(WAC)AND TACOMA MUNICIPAL CODE(TMC).ALL WORK AND MATERIAL f_ DEDICATED CONDUIT HOMERUN TO PANEL&CIRCUIT NUMBERS AS INDICATED ON PLANS CV3 INDICATES ADMINISTRATIVE HANDSET,D INDICATES DESKTOP HANDSET,C INDICATES MOUNTED ABOVE COUNTER,S <br /> TO BUILDING STANDARDS AND CODE UNLESS NOTED OTHERWISE. INDICATES SURFACE MOUNT,SS INDICATES STAINLESS STEEL COVER PLATE WITH MOUNTING STUDS)(#INDICATES QUANTITY <br /> RACEWAY CONCEALED IN WALL OR CEILING OF DATA PORTS AND CABLES,IF DIFFERENT THAN 2). Z <br /> 2. MAINTAIN CONTINUITY AND OPERATION OF ALL EXISTING BUILDING TENANT POWER,LIGHTING, CEILING MOUNTED,DATA OUTLET-WITH(1)DATA PORT AND(1)CAT6A CABLE.MAINTAIN THE COMMUNICATION/DATA OUTLET - Lu <br /> LU 00 <br /> AND LOW VOLTAGE SYSTEMS DURING CONSTRUCTION.PROVIDE JUNCTION BOXES,CONDUITS MARKS INDICATE NUMBER OF#12 AWG UNLESS NOTED OTHERWISE O REQUIREMENTS.COVER PLATE TO BE FLUSH WITH THE BOTTOM OF THE ACCESSIBLE CEILING.(E INDICATES EXISTING TO BE Z E F Q <br /> AND WIRE TO EXTEND EXISTING CIRCUITS AS REQUIRED. GROUNDING CONDUCTOR RETAINED) w� <br /> Lu <br /> 3. ELECTRICAL CONTRACTOR TO REPAIR ANY DAMAGE DONE DURING CONSTRUCTION. /2f2 FLEXIBLE CONDUIT Z O Lu <br /> 4. ELECTRICAL CONTRACTOR TO COORDINATE ANY EXISTING CEILING LIGHT FIXTURES,FIRE III GROUNDING SYSTEM PER CODE o w <br /> ALARM,LIGHTING CONTROL DEVICES THAT WILL REQUIRE REMOVAL AND RE-INSTALLATION TO "I <br /> FACILITATE THE HVAC EQUIPMENT AND DUCTWORK REPLACEMENT. Q JUNCTION BOX-SIZE PER CODE(F INDICATES FIRE ALARM SYSTEM) <br /> a EXISTING PANELBOARD TO BE RETAINED <br /> C/) <br /> PLAN REVIEW REQUIREMENT NOTES <br /> ry <br /> 1. THE ELECTRICAL SCOPE FOR THIS PROJECT IS TO SUPPORT LIGHTING AND HVAC EQUIPMENT Q <br /> REPLACEMENT THAT ARE LIKE-FOR-LIKE OR WILL RESULT TO NO LOAD INCREASE OR LESS <br /> THAN 5%LOAD INCREASE OF THE RATED CAPACITY OF THE ELECTRICAL EQUIPMENT <br /> SUPPLYING THE MODIFIED LOAD.PER WAC-296-4613-900(3)(a)(ii)AND(iii),ELECTRICAL PLAN LIGHTING FIXTURE SCHEDULE <br /> REVIEW IS NOT REQUIRED FOR THIS PROJECT. <br /> SYMBOL FIXTURE DESCRIPTION MANUFACTURERIMODEL# LAMPS V j W MOUNTING&REMARKS QUANTITY TOTAL WATTAGE LLJ <br /> ORACLE LIGHTING# LED 120/ <br /> LIGHTING LOAD SUMMARY <br /> RL1A 1'X4'SURFACE MOUNT FLAT PANEL LED FIXTURE 1 40 PROVIDE WITH 1'X4'SURFACE MOUNT KIT 150 6000 Q <br /> 4FLP1-LED-0OOOL-)=-MVOLT-0OK�5-14-FPL1-LEDSMK 4000 277 Z <br /> ORACLE LIGHTING# LED 120/ Q LLJ <br /> EXISTING LIGHTING REMOVED- RL1B 1'X4'SURFACE MOUNT FLAT PANEL LED FIXTURE 30 PROVIDE WITH TXT SURFACE MOUNT KIT 111 3330 0 = <br /> 14FLP1-LEDSOOOL-LED -MVOLT-0OK-85-14-FPLI-LEDSMK 3000 277 <br /> ::=.;, EXISTING 1X4-(2)32W TS=59W X(291)=17,169W Z U <br /> ORACLE LIGHTING# LED 120/ LLJ C/) <br /> EXISTING 2X4-(2)32W T8=59W X(41)=2 4� 19W RL2 1'X4'SURFACE MOUNT FLAT PANEL LED FIXTURE 1¢FLPi-LED-3000L-XXX-MVOLT-0OK-85-14FK 3000 277 30 PROVIDE WITH TXT FLANGE MOUNT KIT 30 900 w Lu <br /> ` ORACLE LIGHTING# LED 120/ <br /> EXISTING CAN LIGHT-(1)33W CPL=33W X(1)=33W RL3 2'X4'SURFACE MOUNT FLAT PANEL LED FIXTURE 40 PROVIDE WITH ZX4'FLANGE MOUNT KIT 41 1640 J F- <br /> 24FPL1-LED-3000L-XXX-MVOLT-40K-80-24FK 4000 277 Q X <br /> TOTAL=19,621 W U ILL- <br /> REMOVED FIXTURE WATTAGE=7 6�96W RL4 6"RECESSED CAN LED FIXTURE 10 1 10Cf HC6-10-D010-XXX 1000 277 H- Z <br /> ELi EMERGENCY 2 HEAD BUGEYE LED FIXTURE 120/277 277 5 9 45 � = <br /> LLI <br /> TOTAL NEW FIXTURE 11925 J <br /> WATTAGE <br /> CONSTRUCTION NOTES <br /> O ELECTRICAL CONTRACTOR TO SET UP LUMEN OUTPUT REVISIONS <br /> N0. DESCRIPTION GATE <br /> AS INDICATED <br /> DRAWN BY: AB <br /> CHECKED BY: HS <br /> PROJECT MANAGER: HS <br /> DRAWING No. 1 of TOTAL <br /> E0.01 <br /> ELECTRICAL LEGEND AND LIGHTING FIXTURE SCHEDULE DATE: 01/1612025 <br /> SUBMITTAL: PRICING SET <br /> PROJECT No. 240-253 <br />
The URL can be used to link to this page
Your browser does not support the video tag.