3 <br />0 <br />0 <br />a <br />N <br />i <br />CD <br />z <br />z <br />0 <br />CIVIL SYMBOLS <br />STRUCTURAL SYMBOLS <br />SURVEY <br />UTILITY <br />SURFACE & LANDSCAPING <br />GENERAL <br />CONCRETE <br />SYMBOL DESCRIPTION (ABBR) <br />THEOR./ FOUND/ <br />EXIST. PROP. <br />p ANGLE POINT <br />BENCH MARK <br />PIPE <br />' ® MONUMENT <br />® MONUMENT (IN CASE) <br />® MONUMENT (SURFACE)' <br />0 TAX LOT / PARCEL # <br />ti OWNERSHIP TIE <br />x ELEV x ELEV SPOT ELEVATION <br />XX.XX MATCHLINE <br />MATCHLINE <br />SECTION DATA: <br />SYMBOL <br />EXIST. <br />] <br />o <br />a <br />® <br />a <br />� <br />x <br />w <br />Tv? <br />DESCRIPTION (ABBR) SYMBOL DESCRIPTION (ABBR) <br />PROP. PROP. PROP. <br />7 CAP/PLUG <br />o GUARD POST FIRE <br />DI REDUCER <br />THRUST BLOCK —F4—va— 4" FIRE LINE <br />IT WATER METER <br />K FIRE HYDRANT —Fs —vs— 6" FIRE LINE <br />�" AIR RELIEF FDC FIRE DEPARTMENT CONNECTION <br />g 0 FIRE HOSE CONNECTION <br />T BLOW —OFF FIRE EXTINGUISHER &^� <br />x LIFE RING CABINETS <br />oa GATE VALVE (X=UTILITY) <br />P.R.V. <br />WATER <br />PAD MOUNTED <br />TRANSFORMER —w—w— WATER MAIN <br />Tv? UTILITY VAULT no WATER PEDESTAL <br />SYMBOL DESCRIPTION <br />EXIST, PROP. <br />EMBANKMENT <br />� � NA <br />RIP RAP <br />NA <br />HEDGE <br />�w� LD—HEDGE <br />Q CD SHRUB <br />LD—SHRUB <br />�J TREE (Conifer) <br />V V LD—TR—C(L,M OR S) <br />TREE (Deciduous) <br />LD—TR—D(L,M OR S) <br />YARD OR STREET LIGHT <br />LT—YDLIT <br />GRE D ILI NE MARKER <br />GRID LINE <br />rx SOIL/SUBGRADE <br />RUM GRAVEL <br />OPENING IN FLOOR OR WALL <br />XX.XX MATCHLINE <br />MATCHLINE <br />— — REFERENCE LINE, EXISTING OR <br />ARCHITECTURAL ELEMENTS <br />A DIMENSION PER ARCHITECT <br />0 FOOTING TYPE AND <br />(440'-0") BOTTOM ELEVATION <br />— _X=X CONCRETE OVER STEEL <br />STUD FLOOR DECK —LONGITUDINAL <br />N `�'�X`--X`—I CONCRETE OVER STEEL <br />FLOOR DECK—TRANSVERSE <br />WWF <br />CONCRETE CURB/ <br />PARTIAL HEIGHT WALL <br />CONCRETE WALL <br />CONCRETE WALL <br />BELOW THIS LEVEL <br />% EDGE OF CONCRETE <br />` ` <br />IS IS <br />wo cam <br />® ® <br />MC MC <br />SECTION CENTER <br />SECTION CORNER <br />QUARTER CORNER <br />SIXTEENTH CORNER <br />CLOSING CORNER <br />MEANDER CORNER <br />® <br />o <br />� <br />E <br />1 <br />'C3 <br />o <br />® TRANSMISSION ►t <br />TOWER <br />o UTILITY POLE SEWER <br />b UTILITY POLE W/RISER <br />E— UTILITY POLE ANCHOR s s <br />EUTILITY POLE SIDEWALK 0° <br />ANCHOR O <br />1 STREET LIGHT ASSEMBLY O <br />Tfq TELEPHONE RISER ♦ <br />o SAN. SEWER CLEAN OUT STORM <br />VALVE <br />FIRE HYDRANT <br />SEWER LINE <br />DUMP STATION <br />SEWER PUMP <br />SEWER HOSE RACK, <br />SEWER CONNECTION <br />NO SEE BORING SOIL BORING <br />�PLAN SF—BORNG <br />M/E DIMENSION PER MECHANICAL <br />OR ELECTRICAL <br />EL 43'-6" TOP OF STRUCTURE ELEVATION <br />(TOP OF ELEMENT INDICATED) <br />[-14"] ELEVATION POINT <br />(TOP OF ELEMENT INDICATED) <br />WP <br />WORKPOINT <br />DIRECTION OF SPAN <br />CONCRETE COLUMN <br />F_ --I CONCRETE COLUMN <br />LJ BELOW THIS LEVEL <br />CHANGE OF SLAB <br />THICKNESS <br />RAISED SLAB <br />PC-1 PILE CAP IDENTIFICATION <br />CHANNELIZATION <br />SYMBOL DESCRIPTION <br />EXIST. PROP. <br />DISABLED SYMBOL <br />((41 SP—HANDY <br />L1IJ STOP LEGEND <br />NORTH <br />(2) <br />(9 SD MANHOLE TYPE 1—SD—SD— <br />STORM DRAIN <br />NNJJu a NNJJu <br />Cl�o� <br />a SP—STOP <br />@ <br />@ SD MANHOLE TYPE 2 ❑ <br />EXISTING CATCH BASIN <br />STOP BAR <br />LIMIT OF SPAN <br />SH—DATUM <br />® <br />In CATCHBASIN Q <br />PROPOSED CATCH BASIN <br />SLOPE <br />SCALE <br />IN FEET <br />@ <br />@ CATCHBASIN TYPE 2 <br />OUTFALL <br />SURFACE — SLOPE UP <br />20 o <br />20 40 <br />O <br />CW_ <br />—F <br />— FM — <br />OO STORM DRAIN INLET <br />STORM DRAIN CULVERT ® <br />—CW— COLD WATER LINE ® <br />—F FIRE LINE <br />— FM — FORCE MAIN EI <br />TRENCH DRAIN TYPE 1 <br />TRENCH DRAIN TYPE 2 <br />TRENCH DRAIN TYPE 3 <br />SURFACE — SLOPE DOWN <br />1TT� SURFACE — SLOPE TWO WAYS <br />— SS — <br />— SS — SANITARY SEWER LINE <br />—SD— <br />COG <br />DSo <br />—SD— STORM DRAIN LINE OTHER <br />• SANITARY SEWER CLEANOUT <br />FIRE DEPARTMENT CONNECTION ® <br />DOWNSPOUT <br />CONSISTS <br />UTILITY STATERION PEDESTAL <br />OF ONE WATER PEDESTAL & <br />ONE ELECTRICAL PEDESTAL) <br />SURFACE — STEPPED <br />SURFACE — STEPPED & SLOPED <br />® <br />ELECTRICAL <br />X — FENCE <br />PEDESTAL <br />PROJECT LIMITS <br />— R/W — RIGHT—OF—WAY <br />• ...... • • • LIMITS OF FILL <br />TITLES <br />TEXT <br />STEEL <br />FASTENERS <br />SECTION/ELEVATION LETTER <br />PLAN TITLE OR DETAIL/VIEW NUMBER SHEET NUMBER WHERE DRAWN <br />SCALE: 1/8" = 1'—O" SEE 1/S21 FOR INDICATES DIRECTION <br />ADDITIONAL INFO OF CUTTING PLANE <br />TEXT NOTATION LETTER INDICATES <br />A SECTION/ELEVATION TITLE SECTION OR ELEVATION <br />S1.1 SCALE: 3/4" = 1'—O" S <br />53.2 <br />/ \ <br />0 PHASE, DIAMETER <br />& AND <br />FEET, MINUTES <br />INCHES, SECONDS <br />DEGREE <br />o AT <br />CL CENTERLINE <br />R PLATE <br />NUMBER <br />BEAM/GIRDER <br />1��� STEEL IN CROSS SECTION <br />PLAN SECTION <br />+ t CONCRETE ANCHOR BOLT <br />+ DRILLED IN CONCRETE ANCHOR <br />t <br />+ + BOLT <br />+ T NAIL <br />1 DETAIL/VIEW TITLE <br />1 <br />N SHEET NUMBER <br />SECTIOSECTION IS <br />WHERE <br />SHOWN <br />% PERCENT <br />S2.1 SCALE: 3/4" = 1'—O" <br />E <br />S2.1 <br />2 NUMBER INDICATES <br />DETAIL OR VIEW <br />SECTION/ELEVATION/DETAIL/VIEW <br />LABELS <br />ELEVATION <br />S2. <br />SHEET NUMBER WHERE <br />DETAIL DETAIL/ELEVATION IS SHOWN <br />` City of Everett Permit Services <br />EVERETT Reviewed for Permit 07/14/2025 <br />SECTION/ELEVATION/DETAIL/VIEW <br />IDENTIFIERS <br />WASHINGTON <br />IF THIS DRAWING IS NOT 22"x34" SCALE ACCORDINGLY. <br />A S —BUILT S <br />Port O <br />E� ,I„ �, <br />P.O. BOX 536 <br />EVERETT, WA 98206 <br />(425) 259-3164 <br />® ® 3240Eas,ShiAvm981 <br />I I P: 206.. Wa1387 on 98102 <br />P: 206.G24.1387 <br />ENGINEERS, INC.—pndengineers.com <br />AD <br />7//2+ <br />1/2]/25 <br />JBK <br />JBK <br />AS—BUILTS <br />ISSUED FOR PERMIT &BID <br />END ENGINEERS, INC. IS NOT RESPONSIBLE FOR SAFETY <br />PROGRAMS, METHODS OR PROCEDURES OF OPERATION, OR THE <br />CONSTRUCTION OF THE DESIGN SHOWN ON THESE LED OUT, <br />WHERE SPECIFICATIONS ARE GENERAL TO NOT CALLED OUT, <br />THE SPECIFICATIONS SHALL CONFORM TO STANDARDS OF <br />INDUSTRY. DRAWINGS ARE FOR USE ON THIS PROJECT ONLY <br />AND ARE NOT INTENDED FOR REUSE WITHOUT WRITTEN <br />APIN PROVALFROM END. DRAWNGS <br />THAT WOULD CONSTITUTE A SO NOT TO BE USED <br />DIRECTLY OR INDIRECTLY TO PND. <br />_�N BR <br />,S �sH , <br />/ ��� /NF <br />A <br />� <br />AOa 2789 �o �� <br />�sSA0NAL0.E�G\ <br />PROJECT ENGINEER: <br />J. KEISER <br />SCALE: <br />NOTED <br />PORT OF EVERETT <br />DWG. NO. <br />G1.02 <br />DESIGNED C S <br />C. CASTONA <br />DATE <br />JANUARY 2025 <br />C 2 BUILDING ABATEMENT <br />& DEMOLITION <br />GENERAL SYMBOLS M B 0 LS <br />CIP N0. <br />6-8-oo]-O, <br />DRAWN BY: <br />G. DEAN <br />CHECKED BY: <br />W. THOMPSON <br />PROJECT <br />NO. PD—WP-2025-03 <br />APPROVED BY <br />SHEET N0. 3 OF 26 <br />No. <br />DATE <br />ev <br />REVISION <br />