My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10809 16TH AVE SE 2025 Plans 2026-04-13
>
Address Records
>
16TH AVE SE
>
10809
>
Plans
>
10809 16TH AVE SE 2025 Plans 2026-04-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2026 8:28:07 AM
Creation date
4/13/2026 8:27:45 AM
Metadata
Fields
Template:
Address Document
Street Name
16TH AVE SE
Street Number
10809
Permit
FA2504-005
Year
2025
Notes
New Fire Alarm System
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EHA <br /> EVERGREEN COURT SENIOR APTS " 0, <br /> z N <br /> O G <br /> EV`T7 Permit#: FA2504-005 <br /> FIRE ALARM SYSTEM Stat• site Address 10809 i6[h Ave SE L Z o <br /> Everett Fire Dept.Permit Review Applicant: Guardian Security = <br /> Status:Approved Q <br /> Application Date:New Fire Al 1„ <br /> Reviewed By:kbrown Description: New Fire Alarm System r <br /> 04/10/2025 10:51:04 Review Date: 04/10/2025 <br /> AM w <br /> 10809 16TH AVENUE SE, EVERETT, WA 98208 <br /> za <br /> w <br /> - o <br /> SHEET INDEX MONITORING COMPANY SYMBOLS LEGEND o uJ <br /> SHEET # SHEET TITLE (NWAMS) NORTHWEST ALARM MONITORING SERVICES QUANTITY SYMBOL DESCRIPTION MODEL MANUFACTURER BACKBOX MOUNTING HEIGHT Q a <br /> 1743 1ST AVE. S., SEATTLE, WA 98134 1 FACP CONTROL PANEL UD-2000 TO FIRE ALARM AFC-100 POTTER PROVIDED 72" A.F.F. <br /> J A.F.F. <br /> FA-01 SYSTEM INFORMATION 1-(800) 826-9503 w <br /> RADIO WALL MOUNT - ~ <br /> GENERAL NOTES E ®E COMMUNICATOR 7707P-88-ULP-M AES PROVIDED NEAR FRCP <br /> FA-02 TYPICAL WIRING DETAILS & DEVICE MOUNTING HEIGHTS EXISTING <br /> FOR POTTER SYSTEM: REMOTE BOOSTER 66" A.F.F. <br /> DO NOT INSTALL ADDRESSABLE INITIATING DEVICES UNTIL PREPROGRAMMED 2 ""� POWER SUPPLY PSN-106 POTTER PROVIDED TO TOP <br /> FA-03 FACP, AES, NAC1 & NAC2 & DEVICE WIRING DETAILS WITH DEVICES ADDRESS. r <br /> 1. NUMBERS ADJACENT TO DEVICE SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS DEVICE 1 Faa FARE ALARM RA-6500FR POTTER PROVIDED 66" A.F.F. <br /> a <br /> FA-04A FIRE ALARM SYSTEM CALCULATIONS & MATRIX 01-1-02 WOULD BE THE SECOND DEVICE ON ADDRESSABLE LOOP 1. w <br /> 2. DETECTOR AND AUDIBLE CIRCUIT POLARITY SHALL BE OBSERVED. 1 ooc DOCUMENT SS000685 SPACE AGE N/A 66" A.F.F. <br /> FA-04D NAC1 & NAC2 CALCULATIONS BOX ELECTRONICS TO TOP <br /> 3. AUDIBLE/VISUAL CIRCUIT WIRING IS SUPERVISED. NO PARALLEL BRANCHING IS <br /> PERMISSIBLE. s SMOKE SENSOR PAD300-PD WITH 4S DEEP <br /> 47 OP PAD300-6B BASE POTTER W/ 1G RING CEILING <br /> FA-05 1ST FLOOR FIRE ALARM LAYOUT ADDRESSABLE <br /> 4. INSTALLATION SHALL BE IN STRICT CONFORMANCE WITH THE NATIONAL ELECTRIC z <br /> CODE, NFPA 72, LOCAL CODE(S), AND/OR AUTHORITY HAVING JURISDICTION. 2 OF HEAT DETECTOR PAD300-HD WITH POTTER 4S DEEP CEILING o z <br /> FA-06 2ND FLOOR FIRE ALARM LAYOUT (ADDRESSABLE) PAD300-6B BASE W/ 1G RING > o <br /> 5. INSTALLATION MATERIALS (I.E. CONDUIT, WIRE, FITTINGS, HANGERS, STANDARD t HEAT DETECTOR PC-2H POTTER 4S DEEP VERIFY LOCATION <br /> BOXES, FIBER OPTICS CABLE, FITTINGS, AND ASSOCIATED EQUIPMENT) ARE NOT F/RR CONVENTIONAL PC-6D8 BASE W 1G RING IN FIELD <br /> FA-07 3RD FLOOR FIRE ALARM LAYOUT SUPPLIED BY SIEMENS CERBERUS DIVISION. 1 ❑F MANUAL PULL STATION PAD100-PSDA POTTER 4S DEEP 48" A.F.F. w N <br /> 6. DETECTORS SHALL NOT BE MOUNTED IN DIRECT AIR STREAM OF AIR SUPPLY (ADDRESSABLE) W/ 1G RING To CENTER Of z <br /> FA-08 RISER DIAGRAM OUTLETS. PER NFPA 72, 2-3.5.1 DUAL INPUT 4S DEEP VERIFY LOCATION <br /> 2 ®2 MONITOR MODULE PAD100-DIM POTTER W/ 1G RING IN FIELD o <br /> 7. WIRING SHALL BE PER PLAN WITH RESPECT TO CONDUCTOR SIZE & OR CABLE a <br /> TRAY,TYPE, QUANTITY AND COLOR CODE. CONDUCTORS SHALL BE PERMANENTLY AND SINGLE INPUT PAD100-SIM POTTER 4S DEEP VERIFY LOCATION y <br /> UNIQUELY MARKED FOR FUTURE IDENTIFICATION. 2 MONITOR MODULE W/ 1G RING IN FIELD <br /> 8. INSTALLING CONTRACTOR SHALL RETURN ONE SET OF ACCURATELY MARKED RELAY MODULE 4S DEEP VERIFY LOCATION w N <br /> SCOPE OF WORK DRAWINGS FOR "AS BUILT" PURPOSES. 3 ® WITH SINGLE INPUT PAD100-RM POTTER W/ 1G RING IN FIELD a <br /> o � <br /> TYPE OF WORK: BUILDING FIRE ALARM SYSTEM 9• FOR ADDITIONAL INSTALLATION INSTRUCTIONS, REFER TO CATALOG CUT 2 OR MULTI—VOLTAGE <br /> ULTI-OLTAGE MR-101/C AIR PRODUCTS N/A VERIFY LOCATION c <br /> SHEETS AND/OR INSTALLATION INSTRUCTIONS. o aQ <br /> NEW FIRE ALARM SYSTEM 10 THE 120vac POWER ELECTRICAL WORK SUPPLYING FIRE ALARM SYSTEM PANELS 75 LOW FREQUENCY LFH-24W POTTER 4S DEEP 80" <br /> MUST COMPLY WITH ARTICLE 725 AND 760 OF NFPA 70, N.E.C. AND NFPA 72, LF AUDIBLE SOUNDER W/ 1G RING TO BOTTOM <br /> SPECIFICALLY SECTION 1-5.2.5.2: IN REFERENCE TO DEDICATED BRANCH POWER LOW FREQUENCY 4S DEEP 80" A.F.F. <br /> CODE ANALYSIS SOURCES. 120vac POWER SHALL NOT BE APPLIED TO FIRE ALARM PANEL 4 Ir lLF AUDIBLE SOUNDER LFHS-177W POTTER W/ 1G RING TO BOTTOM Cl) <br /> WITHOUT DIRECT SUPERVISION OF FIRE ALARM TECHNICIAN. HORN STROBE <br /> APPLICATION CODES: 11. ALL PANEL NUMBERS AND CIRCUITS WILL BE ON THE RECORD DRAWINGS SET. 16 FIRE ALARM HS-24WW POTTER 4S DEEP 80" A.F.F. w <br /> OCCUPANCY TYPE: "R-1/ A3 MIXED OCCUPANCY HORN/STROBE W/ 1G RING TO BOTTOM <br /> TYPE OF CONSTRUCTION: V - 1 HOUR 2021 INTERNATIONAL BUILDING CODE (IBC) 12. ALL 120VAC CIRCUITS ARE FROM DEDICATED CIRCUITS FROM THE EMERGENCY 4S DEEP 80" A.F.F. <br /> BUILDING IS FULLY SPRINKLERED 2021 INTERNATIONAL FIRE CODE (IFC) GENERATOR. 7 FIRE ALARM STROBE s-24ww POTTER W/ 1G RING TO BOTTOM <br /> NUMBER OF STORIES: 3 2021 INTERNATIONAL MECHANICAL CODE (IMC) 13. PER NFPA 72, SECTION 5-3.6.1.3 DETECTORS SHALL NOT BE ,�, WALL MOUNT <br /> INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS 1 UWP STROBE HS-24WW-WP POTTER WPBB VERIFY LOCATION Q <br /> WEATHERPROOF IN FIELD <br /> 2021 UNIFORM PLUMBING CODE (UPC) COMPLETE AND FINAL. EXCEPTION: WHERE REQUIRED BY THE AUTHORITY HAVING [L <br /> JURISDICTION FOR PROTECTION DURING CONSTRUCTION. DETECTORS THAT HAVE 1 T LOW TEMPERATURE RTS-0 POTTER 1G BOX VERIFY LOCATION Q <br /> 2023 NATIONAL ELECTRICAL CODE (NEC) BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR ® SWITCH IN FIELD <br /> 2021 WASHINGTON STATE ENERGY CODE (WSEC) REPLACED IN ACCORDANCE WITH NFPA 72, CHAPTER 7. - - <br /> BATTERY POWER SONIC <br /> 2 - PS-12180 W LL <br /> 14. WIRING SHALL RUN CONTINUOUS FROM FACP TO FIRST DEVICE ON A CIRCUIT 12V 18AH BATTERY <br /> AND THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER Z w wN O <br /> WIRE DESIGNATIONS & MISCELLANEOUS ABBREVIATIONS BACK BOXES OF DIFFERENT CIRCUITS. _ BATTERY POWER SONIC - - I-�00 <br /> 4 12V 8AH PS-1280 BATTERY w Z O <br /> NOTE: 15. ALL AND�FREEGOFSHALL <br /> SHORTS BETWEEN CON VERIFIED <br /> DUCTORSBAND00 HER CIRCUITS PRIOR GROUND <br /> FINAL BELL PDC-10-24 POTTER - - to>Q <br /> WILL UTILIZE EXISTING FIRE ALARM WIRES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. E �g E H 2 Q� II <br /> EQUIPMENT TRIM. WP (EXISTING) EXISTING Cr SH- LPL <br /> WIRE DESIGNATION 16. ALL CABLES SHALL BE MARKED AS INDICATED ON FIRE ALARM RISER WITH A WATERFLOW - VERIFY LOCATION c~oLU <br /> PERMANENT LABEL AT ALL DEVICES, JUNCTION BOXES AND FACP. F.B.o. 0 SWITCH F.B.O. F.B.O. IN FIELD Q rcC <br /> O Lu M Lu _ <br /> SYMBOL DESCRIPTION NUMBER OF CONDUCTORS SIZE TYPE COLOR CODE TAMPER - VERIFY LOCATION U 9j W LU <br /> 17. THE ELECTRICAL CONTRACTOR SHALL CLEAN ALL DIRT AND DEBRIS FROM THE F.B.O. ❑� SWITCH F.B.O. F.B.O. N FIELD ILL 0 <br /> OUTSIDE AND INSIDE OF THE FIRE ALARM BACK BOXES AND JUNCTION BOXES <br /> A ANNUNCIATOR NETWORK TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) AFTER COMPLETION OF THEIR INSTALLATION. DOOR Z T <br /> D DATA ADDRESSABLE LOOP TWISTED PAIR WITH SHIELD #16 FPL/FPLR RED (JACKET) F.B.O. DH E HOLDER F.B.O. F.B.O. _ VERIFY LOCATION Uj <br /> N FIELD <br /> I INITIATION CIRCUIT TWO #16 FPL/FPLR RED (JACKET) 18. DETECTORS MUST BE RATED FOR TEMPERATURE IN THE ENVIRONMENT IN WHICH 20. (EXISTING) LLJ <br /> P DEVICE OR ANNUNCIATOR POWER TWO #14 FPL/FPLR RED (JACKET) IT IS LOCATED. END-OF-LINE VERIFY LOCATION Ir W <br /> - <br /> S STROBE CIRCUIT Two #14 FPL/FPLR RED (JACKET) 19. ALL WIRING BETWEEN FLOORS SHALL BE LOCATED IN CONDUIT. RESISTOR F.B.O. F.B.O. IN FIELD <br /> T POWER SUPPLY TRIGGER TWO #14 FPL/FPLR RED (JACKET) EXISTING Ir <br /> 20. NFPA 72, 6.4.2.2.2 ALL STYLES OF CLASS A CIRCUITS USING 22. PHYSICAL - E DEVICE - - - - W <br /> DEVICE ADDRESSING MISC. ABBREVIATIONS CONDUCTORS (E.G., METALLIC, OPTICAL FIBER) SHALL BE INSTALLED SUCH THAT rn <br /> THE OUTGOING AND RETURN CONDUCTORS, EXITING FROM AND RETURNING TO THE W `/J <br /> DEVICE ADDRESS DESCRIPTION MISC. DESCRIPTION CONTROL UNIT, RESPECTIVELY, ARE ROUTED SEPARATELY. THE OUTGOING AND <br /> X-XXX X- LOOP# RETURN (REDUNDANT) CIRCUIT CONDUCTORS SHALL NOT BE RUN IN THE SAME Q <br /> (SLC ADDRESSABLE DEVICE) XXX = DEVICE# E EXISTING TO REMAIN CABLE ASSEMBLY(I.E., MULTI-CONDUCTOR CABLE), ENCLOSURE, OR RACEWAY. _ <br /> SX-X-x <br /> Sx= BPS# 21. NFPA 72, A.6.4.2.2.2 A GOAL OF 6.4.2.2.2 IS TO PROVIDE ADEQUATE w <br /> x=CIRCUIT# ER EXISTING RELOCATED TO REMAIN SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES. THIS SEPARATION IS <br /> (VAC ADRESS) X=DEVICE <br /> REQUIRED TO HELP ENSURE PROTECTION OF THE CABLES FROM PHYSICAL <br /> #cd #=VISUAL CANDELA RATING DEMO EXISTING DEVICE To BE REMOVED DAMAGE. THE RECOMMENDED MINIMUM SEPARATION TO PREVENT PHYSICAL SCALE:AS NOTED <br /> (CANDELA) DAMAGE IS 305 MM (1 FT) WHERE THE CABLE IS INSTALLED VERTICALLY AND 1.22 <br /> M (4 FT) WHERE THE CABLE IS INSTALLED DESIGNENBY: <br /> L. ALL <br /> VX-X VX= AMP CIRCUIT# TBD TO BE DETERMINED DRAWN/DESIGNED BY: <br /> . . <br /> (SPEAKER ADDRESS) X=DEVICE# 22. LOCKOUT SHALL BE INSTALLED ON THE MAIN POWER DISCONNECT CIRCUIT BREAKER. S. BURNAM <br /> NFPA 72, 10.6.5.4 CHECKED BY: <br /> #W SPEAKER TAP SETTING A.F.F ABOVE FINISHED FLOOR TAHARM MUHAMMAD T. MUHAMMAD <br /> (wnrrs) #= 23. THE MAIN POWER DISCONNECT CIRCUIT BREAKER SHALL HAVE A RED MARKING. DarE:oa/oa/zs <br /> NFPA 72, 10.6.2.3 NICET LEVEL IV <br /> JOB NUMBER:7B630-1 <br /> F.B.O FURNISHED BY OTHERS 24. PER IFC 509-1 MOUNT A FIRE ALARM CONTROL PANEL SIGN WITH 2 INCH WHITE CERT. 138245 EXP.01/07/2026 SHEET <br /> LETTERS <br /> FIR A RED E PANEL BACKGROUNDLOCATED ON THE OUTSIDE OF THE DOOR LEADING TO THEFA-01 <br /> Proprietary & Confidential, Copyright 2013 by Guardian Secuirilty Systems, Inc. All Ricihis Reserved <br />
The URL can be used to link to this page
Your browser does not support the video tag.