My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10809 16TH AVE SE 2025 Plans 2026-04-13
>
Address Records
>
16TH AVE SE
>
10809
>
Plans
>
10809 16TH AVE SE 2025 Plans 2026-04-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2026 8:28:07 AM
Creation date
4/13/2026 8:27:45 AM
Metadata
Fields
Template:
Address Document
Street Name
16TH AVE SE
Street Number
10809
Permit
FA2504-005
Year
2025
Notes
New Fire Alarm System
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRCP BATTERY CALCULATIONS SEQUENCE OF OPERATION MATRIX <br /> oft 0 � <br /> OCZ N <br /> FIRE ALARM SYSTEM MATRIX SYSTEM OUTPUTS O <br /> H <br /> Project Name:I EHA EVERGREEN COURTSENIOR APTS Standby Hours:24 FACP ANNUNCIATION NOTIFICATION FIRE SAFETY CONTROL = o <br /> 1080916TH AVENUE SE,EVERETT,WA 98208 Alarm Mins:O <br /> ' U) X <br /> AFC-100 Installed By: Efficiency Factor:20% 4 y _ o W 3 Q <br /> Battery&Voltage Drop Designed By:GUARDIAN SECURITY SLC Type:Class B F B $ 1. <br /> W y Llj <br /> Calculations ,, a o <br /> Date:4/4/2025 NAC Source Voltage:20.4 a o 'S H <br /> a - Za <br /> Model#: AFC-100 Max Panel Current(amps):5 <br /> Panel ID:FACP M o ru W LL - i <br /> User assumes all responsibility to ensure the quantities and current � � � < W o � u � <br /> Location:ELECRIC ROOM 133,1ST FLOOR draw values in this worksheet are accurate prior to submittal. w s e o - w <br /> Addressable Fire Panel Standby(amps) Alarm(amps) ° <br /> l PI 1 PI p o w p <br /> City Part it Description Each Total Each Total a _ _ - ; o - > _ <br /> 1 AFC-100 Analog Addressable FACP 0.130 0.130 0.220 0.220 " K ' w ' G w Q <br /> Panel Standby: o o o: LL c S LL o <br /> Y 0.130 Panel Alarm: 0.220 o <br /> Ss a iW'w r S M J <br /> P-LINK(RS-485) Standby Alarm f55 ai a ' ` LL 3 w 8 i n UJ <br /> 1 UD-2000/U D-1000 DACT Card 0.016 0.016 0.023 0.023 Q �° y f f s c 5 o w <br /> 1 RA-6500(R/F) Flush Mount LCD Annunciator 0.020 0.020 0.050 0.050 w w g q* q* g y a 0 5 o B _ <br /> **REQUIRED IF USING NOHMI PROTOCOLSLC DEVICES SYSTEM INPUTS C <br /> (Maximum current draw on P-Link limited to l Amp) P-LINK Standby: 0.036 P-LINK Alarm: 0.073 MANUAL PULL STATIONS X X X X X X X X <br /> *Only enter quantity if PLINK power is being used to power devices <br /> Standby AREA SMOKE DETECTORS X X X X X X X X m <br /> SLC Devices Y Alarm <br /> Un <br /> AREA HEAT DETECTORS X X X X X X X X > <br /> AFC if ARC/IPA Series-PAD100/200 <br /> SMOKE DETECTOR ELEVATOR LOBBY,1ST FLOOR X X X X X X X X X <br /> NEW 1 PAD100-PSSA/PSDA Addressable Pull Station Single/Dual Action 0.000200 0.000200 0.000200 0.000200 SMOKE DETECTOR ELEVATOR LOBBY,3ND FLOOR X X X X X X X X X <br /> NEW 2 PAD300-SIM Single Input Module 0.000240 0.000480 0.000240 0.000480 <br /> NEW 2 PAD300-DIM Dual Input Module 0.000240 0.000480 0.000240 0.000480 SMOKE DETECTOR ELEVATOR LOBBY,SRD FLOOR X X X X X X X X X <br /> NEW 3 PAD300-RM Relay Module 0.000240 0.000720 0.000240 0.000720 <br /> CONVENTIONAL TEMP HEAT I FOR DETECTOR BOTTOM OF PIT X X X X X X X X X V) <br /> AFC/ARC/IPA Series-PAD300 z <br /> SMOKE DETECTOR IN ELEVATOR MACHINERCOM X X X X X X X X X X N z <br /> NEW 47 PAD300-PD Analog Photo Smoke 0.000300 0.014100 0.000300 0.014100 O <br /> NEW 3 PAD300-HD Analog Fixed Temp Heat 0.000300 0.000900 0.000300 0.000900 HEAT DETECTOR IN ELEVATOR MACHINE ROOM X X X X X X X X X a <br /> NAC Circuits(See NAC Configuration below) Standby(amps) Alarm(amps) <br /> Ckt Use Description Total Total WATERFLOW SWRCX X X X X X X X X X w o <br /> 1 Notification FP-1 0.00000 0.21800 DUCT SMOKE DETECTOR X X X X X X X i <br /> 2 Notification POWER SUPPLY TRIGGER 0.00000 0.00000 <br /> NAC Standby: 0.00000 NAC Alarm: 0.21800 VALVE TAMPER SWITCH X X X X X Q <br /> 0 <br /> Battery Calculation Summary Standby(amps) Alarm(amps) COMMUNICATION FAULT X X X <br /> Panel Current: 0.13000 0.22000 z <br /> P-Link Current: 0.03600 0.07300 GENERAL TROUBLE,OPEN CIRCUIT,GROUND FAULT,WIRE TO WIRE SHORT X X X X X <br /> SLC Device Current: 0.01688 0.05288 NOTES: N <br /> NAC Circuit Current: 0.00000 0.21800 <br /> (NOTE 1) DUCT SMOKE DETECTOR ACTIVATION SHALL SHUTDOWN ONLY THE AIR HANDLING UNIT AND FIRE SMOKE DAMPERS IT CORRESPONDS TO. � Y <br /> 1/0 Circuit Current: 0.00000 0.00000 0 <br /> a <br /> SLC Loop Type: Class B Total Standby: 0.182880 Total Alarm: 0.56388 <br /> Device Addresses Used 58 Standby Hours: 24 Alarm Mins: 5 <br /> Device Addresses Available: 100 AH Required: 4.39 AH Required: 0.05 as <br /> Total Combined Standby&Alarm AmpHours Required: 4.44 x <br /> Efficiency Factor:20% rr^^ <br /> Required Battery AmpHours: 5.33 v) Q <br /> Battery AmpHours Provided: Ig <br /> Note:The cabinet will house two 8 AH or IS AH batteries.The charging circuit is rated W z <br /> for up to two 55 AH batteries. C <br /> MG O <br /> I..L <br /> NAC Circuit Configuration&Voltage Drop EHA EVERGREEN COURT SENIOR APTS 4/4/2025 � <br /> 0 <br /> NAC 1 MAX Circuit Current(amps): 3 Source Voltage Used(VDC):20.4 Q LL- <br /> Usage: Notification Description:FP-1 O <br /> U <br /> Ire iype ms en -Way Actual Ohms Max Load(amps) Volts In o s eq W z <br /> #14 Solid 3.19 100 0.638 0.218 20.26 1 16 W W00 W <br /> Circuit Devices Standby(amps) Alarm(amps) W _00 <br /> Qty Lookup Type Description Each Total Each Total WQ �w <br /> NEW 1 Horn strobes otter - - - - c, O.000O202 0.000000 0.198000 0.198000 U) <br /> EXISTING 1 other Notification Potter PDC-10-24 Bell 0.00.0, 0.000000 0.020000 0.020000 Q oZ5 <br /> mal manday:1 0.00000 Total Alarm:1 0.21800 C=F <br /> g F- Z <br /> NAC 2 MAX Circuit Current(amps):3 Source Voltage Used(VDC):20.4 0 Q Ir 0 <br /> rO W O1W � <br /> Usage:Notification Description:POWER SUPPLY TRIGGER U LL oW <br /> Ire pe ms en -Way Actual Ohms Max Load(amps) Volts In o s eq z T- U <br /> #14 Solid 3.19 10 0.064 0.000 20.40 16 W J <br /> Circuit Devices Standby(amps) Alarm(amps) W U <br /> City Lookup Type Description Each Total Each Total <br /> W <br /> otal Standy: 0.00000 Total Alarm: 0.00000 CC � <br /> ***(12V 18AH BATTERIES PROVIDED)*** W <br /> W <br /> _ Q <br /> W M <br /> Li <br /> SCALE:AS NOTED <br /> DESIGNED BY: <br /> L. ALLEN <br /> DRAWN/DESIGNED BY: <br /> TAHARKA MUHAMMAD S. BURNAM <br /> CHECKED BY: <br /> NICET LEVEL IV T. MUHAMMAD <br /> CERT. 138245 EXP. 01/07/2026 DATE:04/04/25 <br /> FIRE ALARM SYSTEM CALCULATIONS & SEQUENCE OF OPERATIONS MATRIX JOB NUMBER:78630-1,/ <br /> SHEET <br /> FA-04A <br /> Proprietary & Confidential, Copyright 2013 by Guardian Secuffly Systems, Inc. All Rights Reserved ( ) <br />