1 2 3 4 5
<br /> D
<br /> DYKEMAN
<br /> EPS Monroe ES Portable #3 ARCHITECTURE + DESIGN
<br /> -dyke,an.ret � 17 6 West Marine View Drive
<br /> 6467 REGISTERED
<br /> ARCHITECT
<br /> C C
<br /> TI 0 Y JAM S EWETT
<br /> VICINITY MAP PROJECT LOCATION PROJECT INFORMATION GENERAL NOTES ARCHITECTURAL SYMBOLS SAT OF WASH GTON
<br /> LEGAL DESCRIPTION 1. CONTRACTOR SHALL VERIFYALL DIMENSIONS AND COORDINATE THE WORK DETAIL
<br /> OF ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT. 1 ,�INDICATES
<br /> " FIRCREST FIVE ACRE TRACTS BLK 001 D-02-PTN OF LOTS 9& INDICATES TYP.,SIM.,REV. PROJECT IDENTIFICATION:
<br /> 10 ALL OF LOT 11 PTNOF LOTS 12&13 BILK 1 BEG NW CDR OF 2. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL A3.0 SIM�(IF USED)
<br /> LOT 11 TH S89'22 16E ALG N LN OF LOT 11 10FT TPB TH S01'13 DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. SHEET NUMBER WHERE
<br /> 55E PILL W LN LOT 11 643.38FT TH S89.03 40E 21.13FT TH ON 3 CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF DETAIL IS LOCATED E P S Monroe ES
<br /> CRV TO L HAV RAD 319.08FT&CONSUMING AN ANG 24'15 03 . THE WORK AS INDICATED ON ALL DRAWINGS.IF ERROR IN LAYOUT, .{./.
<br /> 135.05FT TH ON CRV TO R RAD OF 379.08FT&CONSUMING AN DIMENSIONS,OR DETAILS ARE FOUND BETWEEN ARCHITECTURAL, Portable #3
<br /> ANG OF 24*15 03 160.45FT TH S89'03 40E 345.5OFT TH N00'56
<br /> 20E 584.97FTTO N LN LOT 10 TH N89'22 16W ALG N LN OF LOTS STRUCTURAL,MECHANICAL,ELECTRICAL,CIVIL OR LANDSCAPE DRAWINGS D7 SECTION NUMBER
<br /> 10&11 677.77FT TO TPB SUBJ ESE PUD#1 CONTACT THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING. FOR
<br /> m A5.3 SHEET NUMBER WHERE
<br /> 4. REGULATIONS,STANDARDS,CONSTRUCTION,MATERIALS AND SECTION IS LOCATED
<br /> TAX ACCOUNT NUMBER REQUIREMENTS FOR INSTALLATION OF MATERIALS SHALL CONFORM AND BE Everett Public
<br /> o,sc muse GOVERNED BY THE EDITION OF THE CODE IDENTIFIED IN THE CODES SECTION
<br /> OF THIS SHEET. Schools
<br /> x su„sc y, 00445400100902 r ,
<br /> 5. REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT DETAIL NUMBER
<br /> ,wur� APPLICATION OF DRAWINGS OR DETAILS. L _ _ J A7.5
<br /> SHEET NUMBER WHERE AT
<br /> °ssE ACREAGE 6. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS DETAIL IS LOCATED
<br /> t „mns se # fi 109°"' Ase ARE FOR GENERAL INFORMATION AND CONVENIENCE OF THE CONTRACTOR. 10901 27th Ave S E
<br /> 9.15 ACRES IN ADDITION TO MATERIALS AND FINISHES INDICATED OR SPECIFIED
<br /> ELSEWHERE IN THE DOCUMENTS. A INTERIOR ELEVATION NUMBER
<br /> SILVER LAKE Everett WA 98208
<br /> y aaa a
<br /> 7. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED FLOOR WHERE p2 -�INTERIOR ELEVATION
<br /> GOVERNING CODES INDICATED,OR RELATIVE TO DATUM NOTED ON DRAWINGS. D B VIEW DESIGNATION
<br /> A5.1
<br /> 8. N.I.C.EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS.CONTRACTOR IS SHEET NUMBER WHERE PERMIT SET
<br /> B 1. WAC 51-50INTERNATIONAL BUILDING CODE,2018 EDITION RESPONSIBLE FOR COORDINATING AS REQUIRED BY DETAILS OR SPECIFICATIONS OFOR EQUN AND IPM NT ING WORK C ELEVATION IS LOCATED 03/14/2025 B
<br /> 2. WAC 51-52 INTERNATIONAL MECHANICAL CODE,2018 EDITION INSTALLATION.
<br /> DOOR NUMBER BASED This drawing is:
<br /> 9. F.O.I.C.EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF 101 ON ROOM NUMBER
<br /> 3. WAC 51-54 INTERNATIONAL FIRE CODE,2018 EDITION THIS WORK.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE A 1.Copyright 2025 Dykeman,Inc.
<br /> f WORK AS REQUIRED FOR INSTSALLATION. DOOR LETTER 2.The Architect's Instrument of Professional Service.
<br /> 4. WAC 51-57 UNIFORM PLUMBING CODE,2018 EDITION 3.For use on this project only.Obtain Architect's
<br /> 10.DO NOT SCALE DRAWINGS:CONTACT ARCHITECT FOR ANY NEEDED <��� written permission for any other use or reproduction.
<br /> 5. WAC 51-11 WASHINGTON STATE ENERGY CODE,2018 EDITION CLARIFICATION. U WINDOW AND RELITE TYPE
<br /> 6. 2015 EDITION NFPA STANDARD 72,13,13-D,13-R 2002
<br /> 11.CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER PROJECT NUMBER,
<br /> OWNER ELECTRICAL ENGINEER ICC/ANSI A117.1-2009 ACCESSIBLE AND USABLE BUILDINGSAND FACILITIES MEMBRANE AT THE FLOOR SLAB,WALLS,AND ROOF.BACKER ROD,SEALANT, ROOM_-ROOM NAME
<br /> AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND NAME 2025-013
<br /> ALL EXTERIOR DOORS,WINDOW PENETRATIONS,AND OTHER AREAS OF
<br /> EVERETT PUBLIC SCHOOLS HARGIS ENGINEERS POTENTIALAIR INFILTRATION,INCLUDING STRUCTURAL,MECHANICAL,AND 101 ROOM NUMBER
<br /> 'ELECTRICAL PERMIT D RAW I N G INDEX ELECTRICAL PENETRATIONS.THE CONTRACTOR SHALL REPAIR ANY DAMAGE
<br /> 3900 BROADWAY 1201 THIRD AVENUE,SUITE 600 SUBMITTED TO VAPOR BARRIER OR REPLACE THEM PRIOR TO COVER AS APPROVED.
<br /> EVERETT,WA 98201 SEATTLE,WA 98101 SEPARATELY GENERAL 12.WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDING,THEY - -11h Sol-WALL TYPE TAG MARK DATE DESCRIPTION
<br /> Contact: JENNIFER COLLINS Contact: JEFF HOOVER G01 TITLE SHEET,PROJECT INFORMATION SHALL BE SLOPED AWAY FROM THE BUILDING AS NOTED,BUT IN NO CASE
<br /> Phone: (425)385-4195 Phone: (206)448-3376 LESS THAN 1/8":12".
<br /> Fax: - Fax: (206)448-4450 n'\
<br /> Email: jcollins@everettsd.org Email: jeff.hoover@hargis.biz ARCHITECTURAL A, REVISION IDENTIFICATION
<br /> AS1.0 OVERALL SITE PLAN BUILDING CODE INFO ��REVISION CLOUD
<br /> ARCHITECT RAMPS AND LANDINGS AST.1 PARTIAL SITE PLAN-PORTABLES
<br /> OCCUPANCY. E
<br /> DYKEMAN,INC. WELCOME RAMP SYSTEMS WELCOME RAMPS,LANDINGS, AND STAIRS TYPE OF CONSTRUCTION: VB,NON-SPRINKLERED(PORTABLE) r�WORK POINT,CONTROL POINT,
<br /> 1 OF 1 STANDARD PLANS AND DETAILS OR DATUM POINT •-
<br /> OJECT
<br /> 1716 WEST MARINE VIEW DRIVE 2361 SOUTH 2O0TH STREET BLDG.SQ.FT: 887 SF,ONE STORY TEAM:
<br /> EVERETT,WA 98201 SEATTLE,WA 98198 1.0 KEYED NOTE PRINCIPAL IN CHARGE:!TJJ
<br /> Contact: ZACH HAM Contact: TERRI GORDON 28X32 PORTABLE PLANS BLDG.HEIGHT: 15'-9"
<br /> PROJECT MANAGER: !ZH
<br /> Phone: (425)259-3161 Phone: (866)935-9255 T-1 TITLE SHEET PORTABLE CLASSROM CLUSTER: 887 SF<6,000 SF PROJECT ARCHITECT:1-A-
<br /> A-1 FLOOR PLAN,DOOR AND WINDOW SCHEDULE JOB CAPTAIN: ! M
<br /> Fax: (425)259-5242 Fax: (877)468-3090 A-2 SECTIONS,FASTENING SCHEDULE AND MATERIALS LIST MATERIAL CALLOUT
<br /> OCCUPANT LOAD 45
<br /> A Email: zachh@dykeman.net Email: sales@welcomerampsystems.com A-3 EXTERIOR ELEVATIONS : A
<br /> A-4 DETAILS
<br /> A-5 REFLECTED CEILING PLAN AND DETAILS FIRE PROTECTION: NFPA 72AlIlil
<br /> STRUCTURAL ENGINEER M MECHANICAL PLAN TITLE SHEET, PROJECT
<br /> M-2 MECHANICAL SCHEDULE AND SECTION �INDICATES DIRECTION OF
<br /> E-1 ELECTRICAL PLAN MAGNETIC NORTH
<br /> BRIGGS ENGINEERING,INC E-2 ELECTRICAL SCHEDULE AND DETAILS NORTH INFORMATION
<br /> PO BOX 140537
<br /> F-1 PLANS,NOTES,MODULAR FOUNDATION DEFERRED SUBMITTALS
<br /> GARDEN CITY,ID 83714
<br /> Contact: DEAN BRIGGS FIRE ALARM
<br /> Phone: (208)871-0200 \ BREAK LINE
<br /> Fax: - V
<br /> Email: bdggsengineedng@msn.com
<br /> L City of Everett Permit Services
<br /> EVERETT Reviewed for Permit 04/24/2025
<br /> 1 2 3 4 5"
<br />
|