My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1715 100TH PL SE 2025 Plans 2026-04-13 (2)
>
Address Records
>
100TH PL SE
>
1715
>
Plans
>
1715 100TH PL SE 2025 Plans 2026-04-13 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2026 2:53:41 PM
Creation date
4/13/2026 2:52:45 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH PL SE
Street Number
1715
Permit
B2501-018
Year
2025
Notes
INTERIOR RENOVATION (FULL SCOPE IN NOTES)
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEMOLITION SYMBOL LEGEND <br /> EXISTING WALLS TO BE DEMOLISHED wo <br /> MID ARCHITECTS <br /> EXISTING WALLS TO REMAIN <br /> an6p.S.IN 46216 <br /> 317.55-822 <br /> F EXISTING DOOR TO BE DEMOLISHED <br /> \ <br /> \� EXISTING DOOR TO REMAIN <br /> DEMOLITION GENERAL NOTES <br /> A. THE DEMOLITION DRAWINGS SHOWN AS PART OF THIS SET ARE INTENDED TO SHOW THE <br /> GENERAL SCOPE AND EXISTING CONDITIONS OF THE PROJECT AND THE GENERAL EXTENTS OF <br /> THE DEMOLITION.IT IS NOT THE INTENT OF THE DRAWINGS TO BE ALL INCLUSIVE OF ALL <br /> DEMOLITION NECESSARY FOR NEW CONSTRUCTION AND ARE MEANT TO AID THE CONTRACTOR <br /> IN EVALUATION OF THE EXTENT OF DEMOLITION.THE CONTRACTOR(S)ARE RESPONSIBLE FOR <br /> 6 8 VERIFYING ALL EXISTING CONDITIONS,COORDINATING ALL NECESSARY REQUIREMENTS AND <br /> A34 A34 PERFORMING ALL DEMOLITION REQUIRED FOR NEW CONSTRUCTION WHETHER SHOWN OR <br /> NOT. <br /> B. FIELD INSPECT DEMOLITION SCOPE PRIOR TO REMOVAL.INSURE REMOVAL DOES NOT IMPAIR <br /> STRUCTURAL INTEGRITY OF EXISTING STRUCTURE TO REMAIN.IF FIELD INSPECTION INDICATES <br /> STRUCTURAL INTEGRITY MAY BE IMPAIRED,CONTRACTOR(S)SHALL NOTIFY ARCHITECT/ <br /> STRUCTURAL ENGINEER AND OWNER IMMEDIATELY AND TAKE IMMEDIATE ACTION TO ENSURE <br /> SAFETY OF STRUCTURE WHILE PERMANENT SOLUTION IS DEVELOPED. <br /> C. DO NOT SCALE ANY DRAWINGS.FIELD VERIFY ALL EXISTING CONDITIONS.REPORTANY <br /> DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION. <br /> D. GENERAL CONTRACTOR TO COORDINATE ALL DEMOLITION WORK AMONG ALL TRADES. <br /> E. VERIFY ALL EXISTING WALL,FLOOR,CEILING,AND ROOF CONSTRUCTION TO DETERMINE <br /> _ EXTENT AND METHODS OF DEMOLITION REQUIRED FOR NEW CONSTRUCTION. <br /> b� • WH <br /> F. VERIFY LOCATION OF EXISTING UTILITIES AND UNDERGROUND CONDUITS,CHASES,AND SOIL <br /> i I L_ <br /> CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION <br /> 41 _ • G. MAINTAIN ALL EXISTING EXITS AND EGRESS FOR THE DURATION OF THE CONSTRUCTION. uj <br /> — 14 <br /> —— I EXISTING UNIT HEATER TO REMAIN H. ALL EXISTING SPACES IN OPERATION SHALL BE MAINTAINED WATER TIGHT THROUGOUT <br /> / 14 CONSTRUCTION.EXISTING SPACES REMAINING IN OPERATION SHALL BE MAINTAINED DUST <br /> 2 FREE THROUGHOUT CONSTRUCTION.PHASED AREAS OF WORK ACHIEVING TEMPORARY <br /> —— CERTIFICATE OF OCCUPANCY SHALL THEREAFTER BE MAINTAINED DUST FREE FOR THE <br /> A34 BALANCE OF CONSTRUCTION. \ Q <br /> o / N w <br /> j — I. IF HAZARDOUS MATERIALS ARE UNCOVERED DURING DEMOLITION OR CONSTRUCTION NOTIFY 00 (f) <br /> • • THE ARCHITECT AND OWNER IMMEDIATELY. 0) <br /> J. OWNER WILL REMOVE FURNISHINGS AND LOOSE EQUIPMENT PRIOR TO DEMOLITION. W a a <br /> 5 9 ` K. REMOVE AND/OR DEMOLISH ITEMS INDICATED.THE OWNER HAS THE RIGHT OF FIRST REFUSAL <br /> STORAGE ON EXISTING MATERIALS AND EQUIPMENT REMOVED FROM THE SITE.VERIFY WITH OWNER ALL <br /> 15 \\ g EXISTING MATERIAL,CASEWORK,EQUIPMENT,LIGHT FIXTURES,SYSTEM FURNISHINGS,DOORS, <br /> �\ \ OR FRAMES WHICH SHALL BE SALVAGED PRIOR TO REMOVAL.TURN OVER SALVAGE �/ W Q <br /> Unconditioned EXISTING ROOMS LL <br /> \ \ — MATERIALS TO OWNER ANDIOR STORE ON SITE AS INDICATED BY THE OWNER.CONTRACTOR Ii TO REMAIN- SHALL PROPERLY DISPOSE OF REMAINING ITEMS AND REMOVE FROM THE SITE IMMEDIATELY. a <br /> UNCONDITIONED W <br /> 10 \ / SPACES L. O <br /> \ // 2 Lu O <br /> M. REFER TO MECHANICAL,ELECTRICAL,PLUMBING,AND STRUCTURAL DRAWINGS FOR LL.I O <br /> \ / / ADDITIONAL INFORMATION,DEMOLITION WORK,AND COORDINATION REQUIREMENTS. J <br /> \ \ / N. FOR INFILLING ALL PLUMBING TRENCHES IN CONCRETE,TIE NEW AND EXISTING CONCRETE J <br /> LL <br /> TOGETHER USING#4 REBAR @ 16"D.C.TYP. uj Z <br /> 0. REMOVE ALL EXISTING WINDOW TREATMENTS(MINI-BLINDS,ETC)AND PATCH WINDOW JAMBS <br /> 4 OR HEADS AS REQUIRED. Ir— <br /> EXISTING COLUMNS CD <br /> J <br /> \ ` STORAGE TO REMAIN P. ALL EXISTING LIGHTING,EXIT LIGHTING,EMERGENCY LIGHTING TO REMAIN UNLESS OTHERWISE W CD O <br /> NOTED ON REFLECTED CEILING PLAN OR ELECTRICAL LIGHTING PLAN. <br /> Unconditioned (' � w <br /> p % \ Q. ALL CASEWORK TO BE REMOVED THROUGHOUT. <br /> 14 �,,° / / y STORAGE Q o <br /> R. <br /> PR THE <br /> EXISTING <br /> TO DETERMINE THE EXACT LOCATION OF THE EXISTING � <br /> Unconditioned SANITARY LINE.(GP <br /> S. IT IS THE GENERAL CONTRACTOR'S CHOICE TO REPLACE THE EXISTING GYPSUM BOARD ALONG <br /> 7 \ / \ THE EXTERIOR KNEE WALL IN ITS ENTIRETY WITH NEW GYP.BOARD IF DEEMED MORE O <br /> \ ECONOMICAL AT NO ADDITIONAL COST TO THE OWNER.INDICATE CHOICE WITH BID <br /> \ SUBMISSION. <br /> \ T. ADDITIONAL DEMO WORK MAY BE REQUIRED FOR NEW RECESSED EQUIPMENT,REFER TO <br /> \ B EQUIPMENT PLANS FOR MORE INFORMATION. <br /> \\\ DEMOLITION KEYNOTES <br /> \ II <br /> REMOVE ALL EXISTING SUSPENDED CEILING TILE,DIFFUSERS,AND LIGHTING THROUGHOUT. <br /> \ EXISTING CEILING GRID TO REMAIN. <br /> \\ 2 <br /> O EXISTING SUSPENDED CEILING GRID,TILE TO REMAIN.EXISTING LIGHTING TO BE REMOVED AND <br /> REPLACED. <br /> GARAGE \\\ O PAN OR GYPSUM <br /> NEW CEILIOARD NG WORKING AND LIGHTING TO BE REMOVED.REFER TO REFLECTED CEILING <br /> IMF EXISTING Unconditioned \\\ qO EXISTING GYPSUM BOARD CEILING TO REMAIN.ANY EXISTING LIGHTING TO BE REMOVED AND <br /> REPLACED.PATCH CEILING TO MATCH EXISTING FINISH.REFER TO REFLECTED CEILING PLAN FOR <br /> NEW WORK. <br /> THE 5 REMOVE EXISTING PLUMBING FIXTURE IN ITS ENTIRETY. —I <br /> q (S)ANDI GARAGE SPACES(S--STING SPACES W USED BYDE LTO E BOY SCOUTS OF AMWER LEVEL)WERE IERICA.ALLGINALLY TTOHEESEE O REFER TO PLUMBING PLANS FOR REMOVAL OF EXISTING FLOOR DRAINS AND DRAIN LINES. 8 B AR G ITEC <br /> SPACES WERE UNCONDITIONED EXCEPT FOR THE STAIR(S102)FROM ABOVE.THE <br /> STREET(UPPER)LEVEL FLOOR CONTAINS THE BUSINESS(B)OFFICES OF THE BOY �7 REMOVE CONCRETE SLAB IN THIS CROSS HATCHED AREA.COORDINATE EXACT LOCATIONS OF <br /> SCOUTS OF AMERICA AND ARE CONDITIONED. DEMOLITION WORK WITH ARCHITECTURAL FLOOR PLAN'S NEW CONSTRUCTION. aue ws <br /> OF WASH ON <br /> Og REMOVE PORTION OF WALL FOR NEW DOOR/OPENING.REFER TO ARCHITECTURAL PLAN&DOOR _ `bti — <br /> EXISTING COLUMN SCHEDULE FOR INFORMATION. _ <br /> TO REMAIN O REMOVE PORTION OF WALL AS REQUIRED FOR NEW WORK..REFER TO ARCHITECTURAL PLAN& <br /> DOOR SCHEDULE FOR INFORMATION. <br /> 10 REMOVE EXISTING DOOR AND FRAME AS REQUIRED FOR NEW WORK.PATCH AND REPAIR WALL <br /> AS REQUIRED BY NEW WORK.STORE DOOR FOR POSSIBLE REUSE. <br /> oa� <br /> 11 REMOVE EXISTING SECTIONAL DOOR AND FRAME AS REQUIRED FOR NEW WORK.COORDINATE <br /> WITH OWNER WHETHER OR NOT TO BE SALVAGED.NEW WALL INFILL TO BE INSTALLED AT <br /> EXISTING OPENING MATCH EXISTING MATERIALS AND FINISHES. <br /> AREA IS CONDITIONED SPACE FROM LEVEL ABOVE- EXISTING WINDOW TO REMAIN.REMOVE THE EXISTING SECTIONAL DOOR IN ITS ENTIRETY.PATCH <br /> 109 SQUARE FEET-APPROX. 12 AND REPAIR WALLS AND CEILING AS REQUIRED BY NEW WORK. 00 <br /> 13 REMOVE ALL CASEWORK/SHELVING IN ITS ENTIRETY. <br /> AREA IS SEMI-CONDITIONED SPACE WITH UNIT <br /> HEATERS ONLY-4,561 SQUARE FEET-APPROX. 14 REMOVE WOOD STAIRS,LANDING AND RAILINGS IN THEIR ENTIRETY. <br /> 15 GC TO VERIFY CONDITION OF WOOD PLATFORM FLOOR UNDER EXISTING TOILET.REFRAME AND <br /> PROVIDE 1 1/2"CONCRETE TOPPING TO BE FLUSH WITH ADJACENT SLAB AS NECESSARY. <br /> Q <br /> PLOT DATE JAN 10 <br /> 11 <br /> 025 <br /> PROJECT NUMBER: 2 O-S <br /> SHEET: DEMOLITION FLOOR <br /> PLAN_ <br /> PHASE 1 <br /> A07 <br /> N <br /> n FIRST FLOOR EXISTING PLAN WI DEMO "�F�,pOFS.NTT.GIVEN IN <br /> A07 114"=1'-0" oNLYPuaBTFCT WITH <br /> City of Everett Permit Services Mo<RE`w NT S pj <br /> EVERETT Reviewed for Permit 05/20/2025 NO BEMADEWITHOUr THEPRIORAY <br /> "•••,•••'• WRITTEN CONSENT OF <br /> COMMON'W RIGHTS TARE HEREBY <br />
The URL can be used to link to this page
Your browser does not support the video tag.