1715 100TH PL SE 2025 Plans 2026-04-13 (3)
>
Address Records
>
100TH PL SE
>
1715
>
Plans
>
1715 100TH PL SE 2025 Plans 2026-04-13 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2026 2:55:02 PM
Creation date
4/13/2026 2:54:49 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH PL SE
Street Number
1715
Permit
M2506-016
Year
2025
Notes
Relocating 3 Refrigeration Systems
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOFTOP UNIT SUPPORT PLAN <br />SCALE: %" = V-0" <br />STRUCTURAL NOTES <br />GENERAL REQUIREMENTS <br />BUILDING CODE & REFERENCE STANDARDS: The "International Building Code" (IBC), 2021 Edition, as adopted and modified by the City of Everett, govems the <br />design and construction of this project. Reference to a specific wagon in the Code does not relieve the contractor from compliance with the entire materials <br />reference standards noted below. The latest edition of the materials reference standards shall be used. <br />SCOPE OF STRUCTURAL WORK: Sleeper and attachment design for (3) relocated rooftop HVAC units. <br />DEFINITIONS: The following definitions apply to these general notes: <br />• "Structural Engineer of Record" (EOR)- The Structural Engineer who is legally responsible for stamping& signing the structural documents for the <br />Project. The FOR is responsible for the design of the Primary Structural System. <br />NOTE PRIORITIES: Notes on the individual drawings shall govern over these general notes. <br />STRUCTURAL DETAILS: The structural drawings are intended to show the general character and extent of the project and are not intended to show all details of the <br />work. <br />ARCHITECTURAL DRAWINGS: Refer to the Architectural drawings for information including, but not limited to: dimensions, elevations, slopes, drains, depressions, <br />waterproofing, finishes and other nonstructural items. <br />CONTRACTOR RESPONSIBILITIES: The contractor is responsible for the means and methods of construction and all job -related safety standards such as OSHA <br />and WISHA. The contractor is responsible for the strength and stability of the structure during construction and shall provide temporary shoring, bracing and other <br />elements required to maintain stability until the structure is completed. It is the contractor's responsibility to be familiar with the work required in the construction <br />documents and the requirements for executing it property. <br />DISCREPANCIES: In case of discrepancies between these general notes, the contract drawings, and specifications, anchor reference standards, the FOR shall <br />determine which shall govern. Discrepancies shall be brought to the attention of the FOR before proceeding with the work. Accordingly, any conflict in or between the <br />Contract Documents shall not be a basis for adjustment in the Contract Price. <br />SITE VERIFICATION: The contractor shall verify all dimensions and conditions at the site prior to fabrication anchor construction. Conflicts between the drawings and <br />actual site conditions shall be brought to the attention of the FOR before proceeding with the work. <br />DESIGN CRITERIA <br />DEAD LOAD: <br />Wood Roof =15 pad <br />SNOW LOAD: <br />Roof Snow Load = 25 pat <br />WIND DESIGN: Wind load is determined using Chapter 26 & 29 of ASCE 7-16 in accordance with IBC Section 1609 with the following factors: <br />Basic Wind Speed (3-Second Gust) V = 98 MPH <br />W rid Importance Factor Iw =1.0 Risk -Category = II <br />Exposure Category = B Kzt =1.0 <br />SEISMIC DESIGN: Earthquake design is determined using Chapter 12 ASCE 7-16 in accordance with IBC Section 1613 with the following factors: <br />Importance Factor Is =1.0 <br />Risk Category= II <br />Ste =1,087 g <br />Site Class = D - Default Seismic Design Category= D <br />LIVE LOADS: <br />Roof (Live) 20 PSF <br />TESTS & INSPECTIONS <br />INSPECTIONS: All construction is subject to inspection by the Building Official in accordance with IBC Section 110. The contractor shall coordinate all required <br />inspections with the Building Official. Submit copies of all inspection reports to the ArchmoVEOR for review. <br />WOOD FRAMING <br />REFERENCE STANDARDS: Conform to: <br />(1) IBC Chapter 23 "WOOD.' <br />(2) NDS and NOS Supplement - "National Design Specticabon for Wood Consructior." <br />ALTERNATES: Atemates for specified item may be submitted to the FOR for review. Contractor shall submit a current ICC-ESRIIAPMO-ER report identifying that an <br />alternative component has the same or greater load capacity than the specified tem. <br />IDENTIFICATION: All sawn lumber and pre -manufactured wood products shall be identified by the grade mark or a certificate of inspection issued by the certifying <br />agency. <br />MATERIALS: <br />Sawn Lumber: Conform to grading rules of WWPA, WCLIB, or NI -GA. Finger jointed studs acceptable at interior non-structural walls only. <br />Member Use size Sm'. Grade <br />Sleepers 4x HF No.2 <br />Joist Hangers and Connectors: Simpson Strong -Tie Company Inc. as spedfied in their latest catalogs was used as the basis of design for this project. Alternate <br />connectors by other manufacturers may be substituted provided they have current ICC-ESRIIAPMO-ER approval for equivalent or greater load capacities and are <br />reviewed and approved by the FOR prior to ordering. Connectors shall be installed per the manufacturer's instructions. <br />PRESERVATIVE TREATMENT: Wood materials are required to be 'treated wood" under certain conditions in accordance with IBC Sec 2304.12 "Protection against <br />decay and termites." Conform to the appropriate standards of the American Wood -Preservers Association (AWPA) for sawn lumber, glued laminated timber, round <br />Pa, <br />wood piles, and marine piles. Fallow American Lumber Standards Committee (ALSC) quality assurance procedures. Products shall bear the appropriate mark. <br />Coal all ends of al pressure treated framing with treatment complying with AWPA U1. <br />METAL CONNECTORSIPT WOOD: All metal hardware and fasteners in contact with pressure treated lumber shall be stainless steel Type 316L. At the Owners risk <br />and discretion, hot -dipped galvanized metal hardware and fasteners may be investigated for use in lieu of stainless steel provided that the finish has a minimum zinc <br />content of at least 1.85 oz./SF and its use is coordinated by the Contractor and Wood Supplier for the expected environment and moisture exposure for appropriate <br />use based tin the method of preservative treatment of the wood. <br />(1) %"0 x 3%" SIMPSON SIDS <br />SCREW UNIT -TO -SLEEPER <br />@ EA CORNER OF EA UNIT. <br />CENTER IN SLEEPER. <br />SLEEPER FOR ADJACENT <br />UNIT, WHERE OCCURS. <br />CENTER SPLICE OVER <br />(E) JOIST <br />,_I WW„ MIN, TYP. <br />MIN, TYP. <br />(1) 0.220"0 x 8" SIMPSON <br />SOWS SCREW <br />SLEEPER -TO -JOIST, TYP <br />EA JOIST @ SLEEPERS <br />PERPENDICULAR TO <br />JOISTS. COUNTERSINK <br />FOR 1 YV PENETRATION TO <br />JOIST TOP CHORD <br />ROOFTOP UNIT PER PLAN <br />SLEEPER PER <br />PLAN,TYP. <br />(E) JOIST, <br />T/SHTG <br />NOTE: FIELD VERIFIY UNIT BASE MATERIAL AT SCREW ATTACHMENT IS 27 MILS (22 GAUGE) MIN. <br />TYPICAL RTU ATTACHMENT <br />SCALE: N.T.S. �D12 <br />M <br />U M <br />0 <br />Z rn <br />C!i <br />ti <br />LU C rya <br />LJJ - Y <br />Z <br />�— aJ <br />Z bA i <br />LU y of o <br />LJO <br />J �y � CZJ <br />Wm o N <br />_ co <br />LO <br />1 0 4 <br />?@9:::W4V <br />SEAL: <br />S. COZZJ� <br />R R� p4 WA8g�Qyd� <br />a� <br />� r4 <br />�39519 C <br />,�IortAt � <br />07/15/2025 <br />CO <br />LU 00 <br />U 00 <br />M <br />Q <br />LJJ 0 <br />N � � <br />L0_ U Luu <br />Z 0 LLi <br />L LJ LJ Cl) <br />LU <br />� a- <br />Qc O <br />G 0:� Ln <br />0 <br />PROJECT#: 25-094 <br />DRAWN BY: JCM <br />DESIGNED BY: JCM <br />DATE: DESCRIPTION <br />04.24.2025 PERMIT <br />07.15.2025 COMMENT RESP. <br />JURISDICTIONAL STAMP: <br />SHEETTITLE: <br />ROOFTOP PLAN & <br />DETAIL <br />SHEET NUMBER: <br />S1.0 <br />City of Everett Permit Services <br />EVERETT Reviewed for Permit 07/29/2025 <br />