1715 100TH PL SE 2025 Plans 2026-04-13 (4)
>
Address Records
>
100TH PL SE
>
1715
>
Plans
>
1715 100TH PL SE 2025 Plans 2026-04-13 (4)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2026 2:58:09 PM
Creation date
4/13/2026 2:57:46 PM
Metadata
Fields
Template:
Address Document
Street Name
100TH PL SE
Street Number
1715
Permit
M2503-020
Year
2025
Notes
MECH T/I FOR BASEMENT & 1ST FLR, FULL SCOPE IN NOTES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYMBOLS LEGEND <br />EXISTING DUCT WORK, GRILLS AND EXISTING UNITS <br />NEW SUPPLY AIR DUCT WORK, GRILLS AND NEW UNITS <br />NEW RETURN AIR DUCT WORK AND GRILLS <br />NEW EXHAUST DUCT WORK, GRILLS AND FANS <br />NEW ERV DUCT WORK, GRILLS AND UNITS <br />FLEX DUCT WORK SUPPLY OR RETURN <br />L M UNIT SUPPLY AIR DUCT DROPS <br />® N UNIT RETURN AIR DUCT DROPS <br />® SUPPLY AIR GRILLS <br />® SUPPLY AIR GRILLS <br />® SUPPLY AIR GRILLS <br />c�i SIDEWALL SUPPLY AIR GRILLS <br />RETURN AIR GRILLS <br />SIDEWALL RETURN AIR GRILLS <br />Z ® EXIS I ... ... ,, <br />12 <br />GRILL COLLAR SIZE <br />250 <br />CFM AT GRILL <br />20X20 <br />GRILL SIZE <br />120 <br />DUCT WORK SIZE <br />HAND DAMPER TO ADJUST CFM <br />❑F <br />CEILING FAN <br />-� <br />INLINE FAN <br />OT <br />THERMOSTAT <br />Z-1 <br />NEW ZONE# <br />ZD-1 <br />NEW ZONE DAMPER WITH MOTOR <br />R/D <br />REDUCT EXISTING GRILL <br />M <br />MOVE EXISTING GRILLS, THERMOSTAT AND UNIT <br />DUCT CONNECTION <br />.. ■ ... <br />MAINTENANCE SPACE <br />S/D <br />SMOKE DETECTOR <br />F/S/D <br />FIRE SMOKE DAMPER <br />C/R/D <br />CEILING RADIATION DAMPER <br />ALL WORK, ALL EQUIPMENT, <br />ALL PARTS TO BE INSTALLED, <br />WILL BE IN FULL COMPLINCE <br />WITH ALL CODES BELOW. <br />2021 <br />WSEC <br />2021 <br />IMC <br />2021 <br />WSIMC <br />2023 <br />NEC <br />2021 <br />IFC <br />2021 <br />IBC <br />2021 <br />UPC <br />ALL EQUIPMENT WILL BE TESTED <br />WITH REPORT PER CODE C408.2 AND <br />SECTION C403. <br />ALL SUPPLY AIR GRILLS WILL AIR <br />FLOW TESTED AND ADJUSTED WITH <br />REPORT PER CODE. <br />ALL DUCT WORK WILL BE INSULATED <br />TO CODE PER 2021 IMC AND 2021 WSEC. <br />ALL NEW FLEX DUCT WORK WILL BE NO <br />LONGER THAN 7 FEET. <br />IF APPLICABLE TO THIS JOB ALL DUCT <br />WORK TO BE WILL BE RATED FOR <br />PLENUM RETURN AIR SYSTEM <br />TABLE G03.10.1.2 <br />SUPPLY. RETURN, EXHAUST, and RELJEFAIR DUCTWORK INSULATION <br />Duct Location end Us <br />Climone <br />od <br />Oiled- <br />4C <br />R-8 <br />See Section C403.10.1.2 for <br />Air <br />outside the bullding(outdoors and <br />details <br />o I,p <br />or Return <br />exposed to weathert <br />Air <br />SupplyAir <br />Outside the building (outdoors and <br />5B <br />R-12 <br />See Section C403.10.1.2 for <br />or Return <br />exposed to weather <br />details <br />Air <br />SupplyAlr <br />Unconditioned space (enclosed but not in <br />4Cand <br />R-6 <br />See Section C403.10.1.2for <br />or Return <br />the building conditioned envelope) <br />SB <br />details <br />Air <br />Supply Air <br />Unconditioned space where the duct <br />4Cand <br />R-3.3 <br />See IMC Section 603.12 for <br />or Return <br />coneys al rlhatiswlthln l5°F of the air <br />SB <br />additional requirements for <br />Air <br />remperawre of the surrourlding <br />condensation control at <br />unconditioned space <br />ductwork <br />SupplyAlr <br />Where located In a building envelope <br />4Cand <br />R-16 <br />Duct or plenum is separated <br />or Return <br />assembly <br />56 <br />from building envelope <br />Air <br />assembly with the minimum <br />Insulation value <br />SupplyAir <br />Within conditioned space where the <br />4Cand <br />R-3.3 <br />See Section C403.10.1.2 for <br />supply duct conveys air that is less than <br />58 <br />details <br />55°F or greater the n 105°F <br />Supply Air <br />Within conditioned space that the duct <br />4Cand <br />None <br />See Section C403.10.1.2 for <br />directly serves where the supply duct <br />56 <br />detalls <br />conveys air that is less than 55°F or <br />greater than 105°F <br />Supply Alr <br />Within conditioned space where the <br />4Cand <br />None <br />supply duct conveys air that is 55°For <br />58 <br />greater and 105°F or less <br />Return or <br />Within conditioned space, downstream of <br />4C <br />R-B <br />Exhaust <br />an energy recovery media, upstream of <br />Air <br />an utomoR shutoff damper <br />Return or <br />Within conditioned space, downstream of <br />SB <br />R-12 <br />Exhaust <br />an ene ecowry media, upstream of <br />Air <br />an uromav shutoffdamper <br />Reliefor <br />CondiOonetl space and downstream of <br />4Cand <br />116 <br />Exhhalust <br />an utomaU shutoffdamper <br />sa <br />GENERAL NOTES <br />DUCTWORK <br />1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH <br />DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4" TO EACH DIMENSION IF THE <br />DUCTWORK IS ON THE INTERIOR OF THE BUILDING. <br />1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND IS <br />THE HEIGHT. <br />1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS <br />THAN 25 AND A FLAME SMOKE DEVELOPMENT LESS THEN 50, PER ICM 602.2.1. <br />1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN <br />112 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT <br />PRESSURES ABOVE 112 WATER COLUMN SHALL BE SEALED IN ACCORDANCE WITH <br />STANDARD RS-7. <br />1.5 ALL DUCT GAUGES PER SMACNA, ICM 603-4. <br />1.6 ALL DUCT SUPPORTS PER SMACNA, ICM 603-10. <br />1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR PER ICM <br />1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. <br />INSULATION <br />2A INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. <br />2.2 INSULATE REFRIGERANT & CONDENSATE PIPING PER 2021WA. STATE ENERGY <br />CODES. <br />GENERAL CONTRACTOR <br />3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, <br />FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE <br />PROOF LININGS PER IMC & IBC. <br />3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH <br />ERL BEFORE FRAMING OPENINGS. <br />3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS <br />REQUIRED FOR MECHANICAL WORK. <br />3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED <br />FOR MECHANICAL WORK. <br />3.5 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL <br />MECHANICAL EQUIPMENT. <br />3.6 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE <br />ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. <br />3.7 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OR T-BAR CEILING <br />AS REQUIRED FOR HVAC INSTALLATION. <br />3.8 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED <br />FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL <br />BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC, <br />ELECTRICAL <br />4.1 ASH TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED <br />BY ELECTRICAL CONTRACTOR. <br />4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, <br />DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. <br />4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS, <br />WITH ASH MECHANICAL PLAN AND WITH FIELD LOCATIONS. <br />4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT <br />SWITCH. <br />4.5 ASH TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH <br />CAPABILITY OF 5°F DEADBAND. <br />4.6 ASH TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. <br />4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF <br />EACH PIECE OF MECHANICAL EQUIPMENT. <br />PLUMBING <br />5.1 PLUMBING CONTRACTOR OFFSETS VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH <br />AIR INTAKES OR 3' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1 <br />5.2 CONDENSATE DRAINS FROM RTU BY ERL TO DRAIN WITHIN 12" OF UNIT. CONDENSATE <br />DRAINS FOR AIR HANDLERS BY PLUMBER. <br />ENERGY CODE COMPLIANCE <br />6.1 THE SUPPLY HEATING AND COOLING ENERGY TO EACH ZONE SHALL BE CONTROLLED <br />BY INDIVIDUAL THERMOSTATIC CONTROLS CAPABLE OF RESPONDING TO <br />TEMPERATURE WITHIN THE ZONE. AT MINIMUM, EACH FLOOR SHALL BE CONSIDERED <br />A ZONE. <br />6.2 OUTDOOR AIR SUPPLY, EXHAUST OPENINGS AND RELIEF OUTLETS SHALL BE <br />PROVIDED WITH CLASS IA MOTORIZED DAMPERS WHICH CLOSE AUTOMATICALLY <br />WHEN THE SYSTEM IS OFF PER WW SECTION C403.79.13. <br />MECHANICAL CODE COMPLIANCE <br />7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS <br />IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. <br />DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. <br />TABLE C403.10.1.1 <br />OUTDOOR AIR DUCTWORK INSULATION <br />Minlmu <br />Duc <br />uLY Loc■tlon an <br />Iima t <br />n <br />IrR <br />Note <br />nstalled Du <br />Insulation lP <br />e <br />alu <br />Inside conditioned <br />See Section <br />Outdoor <br />space and u stream <br />4C and <br />a 2800 <br />C403.10.1.1 for <br />Air <br />of rRomaN shutoff <br />56 <br />CFM <br />R-16 <br />additional <br />damper <br />requirements <br />Inside conditioned <br />Outdoor <br />space and downstream <br />of InomaN shutoff <br />4C <br />z 2800 <br />R-8 <br />Air <br />CFM <br />damper to HVAC unit or <br />room <br />Inside conditioned <br />Outdoor <br />space and downstream <br />of trtomati shutoff <br />513 <br />Z 800 <br />R-12 <br />Air <br />damper to HVAC unit or <br />CFM <br />IFM <br />room <br />See Exception 1 <br />Outdoor <br />Inside conditioned <br />4Cand <br /><2800 <br />to Section <br />Air <br />space <br />5B <br />CFM <br />R-7 <br />C403.10.1.1 for <br />additional <br />details <br />folent Marl <br />Project <br />Project Address: - <br />mfomm0on <br />Cernaed CommissioningProfessional: <br />Type of CCeFhfication and Number: -- <br />13 'Vlan uals, record documents and training have been completed or are scheduled (Section C103.6) <br />Supporting <br />Documents <br />° Buiding, operations and maivtevance ridbenabou (C103.6.2) have, been submitted to the owneror <br />sefieduled date: <br />Mamie is (C103.6.2.1) bane been submitted to the turner or scheduled date- <br />° CompliIince documentation (C103.6.3) has been proi-ided to the enner or scheduled date: <br />• System operation training (Cl 03:5-4) has been Provided to the owner or scheduled date: <br />Commissioning Plan <br />❑ Commissioning Plan was used dining construction (Section C408.12) <br />Cammtselonifng Report <br />LJ Camunissianing Report has been submitted Seeman MOR_1.3 <br />LI _'Mechanical Systems were included to the commissioning Process Secnon C408 2 <br />❑ Testing, adjusting and baianang . complete (Section C4D8.2.2) <br />❑ There are unresolved deficiencies with the mechanical systems_ These are described m the attached <br />Cotntnissioning Report submitted to the Oc ner_ <br />❑ Service Water Heating Systems were included in the cnmmissica ing process (Section CG90S3) <br />L7 There are unresolved deficiencies with the service matey headingsys tems- These are described in the <br />attached Commsssioning Report submstted to the i3m, r <br />❑ Controlled receptacles and lighting control systems were included m the commissioning process <br />(Section C408-4} <br />I <br />Corrariissioned <br />Systems <br />❑ There are umresohn-d deficiencies wcrh the electrical pewee and7or automatic lighting controls These arc <br />lesrbed m the attached Commisuoniue Report submitted to the Owner. <br />❑ Additional systems were included in the mmmissioaing process (Section C408.5) <br />❑ 79aere are xmresolvad deficiencies with sz=s[ems ed by C406 ar C407- These are described in the <br />attached Commiestowng Report submitted to the ner. <br />❑ l4feteiing systems were included in the commissioning process (Section C408.6) <br />❑ Thexe are snresolved deficiencies with the metering s stem. These are d---bed in the attached <br />C.-miSsienitig Report submitted to the Omer. <br />❑ Refrigeration systems vrer included in the commissioning process (Sefton G408.7) <br />❑ ilsere aze uneesolved deficiencies with systems required b3' Soctian C410. These are described in the <br />attached Comm_s urnming Report subnomed in the Cmcner. <br />I hereby c t relqurrement5 or Sochan C40S System Comtntssaonmg 'e en comg eted m <br />accordance with the 5S asltington State Energy Code mcltldiug al] items abo�z. <br />Certification <br />Certified Conunissionvtg professional Date <br />❑ I hereby certify thud. requuemeats fat Section C40& Syst,.m Cat1>mmssianhLe have been completed in <br />accordance tutYh the p7ashisaz#on State F �� Code, mcludiin5 all iYema ataoce- <br />Building Owner or Gunn s Rq-ecratrve Data <br />00 <br />CD <br />N <br />00 <br />W <br />W <br />W <br />W <br />fin <br />J <br />_ <br />I- <br />C:) <br />C:) <br />L0 <br />L City of Everett Permit Services <br />EVERETT Reviewed for Permit 07/03/2025 <br />
The URL can be used to link to this page
Your browser does not support the video tag.