My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
KLB Construction, LLC 4/21/2026 (3)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
KLB Construction, LLC 4/21/2026 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2026 2:02:45 PM
Creation date
4/21/2026 1:47:14 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KLB Construction, LLC
Approval Date
4/21/2026
Council Approval Date
4/8/2026
Department
Public Works
Department Project Manager
Randy Loveless
Subject / Project Title
PGSF West Marine View Drive Storm and Combined Sewer, Package 2 Volume 3
Public Works WO Number
UP3815-02
Tracking Number
0005222
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
PLPLPLPLPL215 <br />226 <br />50271 <br />MIC <br />24.82 <br />29051900203400 <br />UNKNOWN <br />29051900201900 <br />UNKNOWN <br />29051900200300 <br />1900 W MARINE VI <br />E <br />W <br /> <br />D <br />R <br />B <br />CD-2610 <br />LOWER NORTON AVE <br />WEST MARINE VIEW DRIVE <br />EX 12" FM DIP <br />EX 16" W DIP <br />EX 12" SD CONC <br />EX 6" P PVC <br />EX 30" SS DIP <br />EX 6" HPG <br />29281520251617181921222324262714 <br />15 <br />FM FM3 <br />4 <br />1 <br />1 <br />C-2065 <br />FMFMFM <br />FM FMCONFIRM LOCATION <br />OF EX GAS LINE <br />12" DIP <br />(FULLY RESTRAINED) <br />EX 12" FM DIP (REMOVED) <br />ENCASE 30" CO01 BELOW <br />PIPE AND FITTING <br />CONNECT TO EX 12" DIP <br />EX 12" FM DIP <br />12"x12"x12" TEE DIP <br />RELOCATE EX WRONG <br />WAY/SPEED LIMIT SIGN(S) <br />6 <br />3 <br />51 <br />4 <br />45° VERT BEND <br />N:364284.99, E:1302279.07 <br />?Surveyed By # Date # Control Monument # City of Everett Field Book/Starting Page # / ###Filepath\FilenameC:\USERS\TFRANKLIN\DC\ACCDOCS\BC ACC PROJECT HUB\103977 - EVERETT CONVEYANCE PACKAGES A_C_E\PROJECT FILES\300 DESIGN\UP3815-02\CAD\002 C\SHEETS\3815-02-C-2065.DWGPlot date 12/8/2025 10:39 AM Plotted by Travis Franklin Last saved by TFranklin Plot style Everett-2016.stb Sheetset Name ####################### <br />0 FEET20 20 4010 <br />CIVIL <br />UTILITY RELOCATION PLAN - 6 <br />C-2065 <br />27 <br />B. O'NEILL <br />T. FRANKLIN <br />K. WEBER <br />PLAN <br />SCALE: 1"=20" <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER STORAGE FACILITY <br />WEST MARINE VIEW DRIVE <br />STORM AND COMBINED SEWER DESIGN <br />WORK ORDER UP3815-02 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />142RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PRELIMINARY44572 <br /> MATCHLINE SEE DRAWING C-2065Know what's below. <br />before you dig.Call <br />RMATCHLINE SEE DRAWING C-2064GENERAL NOTES <br />1.THE EXISTING UNDERGROUND UTILITIES SHOWN <br />HEREIN ARE APPROXIMATE LOCATIONS ONLY BASED <br />ON THE FIELD LOCATION OF UTILITY LOCATE PAINT <br />MARKS AND PHYSICAL FEATURES VISIBLE ON OR <br />ABOVE THE GROUND SURFACE. THE CONTRACTOR <br />SHALL DETERMINE THE LOCATION OF ANY AND ALL <br />UNDERGROUND UTILITIES BEFORE BEGINNING <br />WORK. THE CONTRACTOR SHALL BE RESPONSIBLE <br />FOR ANY AND ALL DAMAGES ARISING OUT OF THEIR <br />FAILURE TO EXACTLY LOCATE AND PROTECT ALL <br />EXISTING UTILITY FACILITIES. <br />2.WORK AROUND POWER AND GAS UTILITIES MUST <br />BE PERFORMED IN ACCORDANCE WITH PSE AND <br />SNOPUD REQUIREMENTS. COORDINATE <br />CONSTRUCTION ACTIVITIES AND SCHEDULE WITH <br />UTILITY OWNERS. SEE SECTION 02 01 10 AND <br />SECTION 02 01 20. <br />3.EXISTING WATER LINE CAN BE REMOVED FROM <br />SERVICE DURING INSTALLATION PER SECTION 01 12 <br />16 AND SECTION 02 01 10 SOUTH OF THE PGSF <br />FACILITY. MAINTAIN WATER SERVICE AT THE PGSF <br />FACILITY AND TO THE NORTH AT ALL TIMES. <br />FORCE MAIN CONSTRUCTION NOTES <br />1 REMOVE AND REPLACE EX 12" FM DI AS SPECIFIED <br />AND AS REQUIRED TO COMPLETE THE WORK. <br />PROVIDE BYPASS PUMPING PER SECTION 33 01 30.50. <br />3 CONNECT TO EXISTING NAVY SS FM MAIN IN <br />ACCORDANCE WITH SECTION 02 01 10. POTHOLE <br />LOCATION PRIOR TO PROCUREMENT OF DIP PIPE AND <br />APPURTENANCES. CONNECTION TO EXISTING FM <br />MUST BE FULL RESTRAINED. <br />4 PROVIDE 12" DIP IN ACCORDANCE WITH SECTION 33 <br />05 31. FM SHALL BE FULLY RESTRAINED. MATCH <br />EXISTING FM COVER, MIN 3-FT COVER. <br />5 PROVIDE DR17 HDPE PIPE PER SECTION 33 05 33.23. <br />6 PROVIDE 12" PLUG VALVE. <br />NAVY FORCE MAIN CONNECTION TO CO03 <br />SCALE: 1"=5' <br />1 <br />C-2065 <br />NOTE: <br />PRIOR TO PROCUREMENT OF PIPE, FITTINGS, VALVES, <br />VALVE ACTUATORS, OR COVERS, CONFIRM DEPTH OF <br />COVER ON EX 12" DIP AND VALVES, AND LOCATION <br />OF EX GAS. FIELD LOCATE VALVES, FITTINGS AND <br />CONNECTION AS REQUIRED. <br />12/09/2025
The URL can be used to link to this page
Your browser does not support the video tag.