My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
KLB Construction, LLC 4/21/2026 (3)
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
KLB Construction, LLC 4/21/2026 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2026 2:02:45 PM
Creation date
4/21/2026 1:47:14 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KLB Construction, LLC
Approval Date
4/21/2026
Council Approval Date
4/8/2026
Department
Public Works
Department Project Manager
Randy Loveless
Subject / Project Title
PGSF West Marine View Drive Storm and Combined Sewer, Package 2 Volume 3
Public Works WO Number
UP3815-02
Tracking Number
0005222
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
PLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLPLTCETCETCETCETCETCETCETCETCETCETCETCETCETCETCETCETCETCETCETCE <br />PORT OF EVERETT <br />NORTON TERMINAL <br />50.00'25.00'192'± <br />LIMITS OF TEMPORARY <br />CONSTRUCTION <br />EASEMENT FOR ACCESS <br />TCE AREA 2 <br />KEEP AREA CLEAR FOR <br />SHARED ACCESS <br />2 <br />7 <br />3 <br />7 <br />3 4 <br />6 <br />1 <br />FEDERAL AVE <br />WEST MARINE VIEW DRIVE <br />BNSF ROW <br />TEMPORARY GATE <br />TERMINAL AVEEXIST GATE 2 <br />7 25'7 <br />7 <br />EXIST FENCE <br />CORNER <br />EXIST FENCE <br />CORNER <br />2 <br />10 <br />EXIST FENCE <br />CORNER <br />72 <br />850.00'10 <br />EXISTING CITY <br />UTILITY EASEMENT <br />EX PAVEMENT <br />STRIPING <br />11 <br />Designed <br />ACTION APRVDDATE <br />Drawn <br />Checked <br />REVISIONDATENO.APRVD <br />PLANS ISSUED FOR 3200 Cedar Street <br />Everett, WA 98201 <br />425.257.8800 everettwa.gov <br />PORT GARDNER STORAGE FACILITY <br />WEST MARINE VIEW DRIVE <br />STORM AND COMBINED SEWER DESIGN <br />WORK ORDER UP3815-02 <br />ACTION APRVDDATE ACTION APRVDDATE <br />BID CONST <br />Design Review Level <br />142RECORD <br />Of Total <br />Sheet No. <br />Drawing <br />PRELIMINARY44572 <br /> <br />GENERAL <br />NORTON TERMINAL <br />TCE ENLARGEMENT PLAN 1 <br />G-2015 <br />7 <br />K. WEBER <br />T. FRANKLIN <br />K. WEBERSurveyed By # Date # Control Monument # City of Everett Field Book/Starting Page # / #Filepath\FilenameC:\USERS\TFRANKLIN\DC\ACCDOCS\BC ACC PROJECT HUB\103977 - EVERETT CONVEYANCE PACKAGES A_C_E\PROJECT FILES\300 DESIGN\UP3815-02\CAD\001 G\SHEETS\3815-02-G-2015.DWGPlot date 12/8/2025 9:26 AM Plotted by Travis Franklin Last saved by TFranklin Plot style Everett-2016.stb Sheetset Name #####################20 804040FEET0 <br />1 PROVIDE TEMPORARY FENCING PER SECTION 01 56 26 <br />AND DETAIL 2/CD-2613. <br />2 PROTECT EXISTING PORT SECURITY FENCE IN PLACE. <br />3 REMOVE AND REPLACE EXISTING SECURITY FENCE AND <br />GATES AS REQUIRED TO COMPLETE THE WORK. SEE <br />ADDITIONAL INFORMATION ON CX-2001 AND CX-2002. <br />4 PROVIDE TEMPORARY 25 FT GATE. KEEP ACCESS CLEAR <br />FOR SNOPUD AND PORT ACCESS. COORDINATE LOCATION <br />WITH THE CITY. <br />6 CLEAR AND GRUB AREA. PROVIDE TEMPORARY HAUL <br />ROAD PER DETAIL 3/CD-2611. <br />7 PROVIDE TESC BMP TO PREVENT MIGRATION TO SURFACE <br />WATER, SEDIMENT OR DEBRIS INTO THE PORT SITE OR <br />ADJACENT PROPERTIES. BMP SHALL BE INCLUDED IN <br />CONTRACTOR'S TESC PLAN. AT A MINIMUM, PROVIDE SILT <br />FENCING IN UNIMPROVED AREAS AND COMPOSITE SOCK <br />ON PAVED AREAS UNLESS OTHERWISE REQUIRED OR <br />APPROVED. <br />8 AT THE COMPLETION OF CONSTRUCTION AND USE, <br />RESTORE THE EXISTING ASPHALT TO PRE-CONSTRUCTION <br />CONDITION INCLUDING GRADE AND DRAINAGE, ALL <br />MARKERS, STRIPING, SEALANTS, AND OTHER <br />IMPROVEMENTS. AT A MINIMUM, MILL AND OVERLAY <br />2-INCH OF ASPHALT PAVEMENT. <br />9 REMOVE AND REPLACE EXISTING IMPROVEMENTS AND <br />LANDSCAPING AS REQUIRED TO COMPLETE THE WORK <br />AND PROVIDE ACCESS FOR TRANSIT THROUGH THE SITE. <br />MAINTAIN ACCESS AT ALL TIMES. <br />10 PROVIDE INLET PROTECTION ON ALL STORM CHANNELS, <br />BASINS, AND MANHOLES (BMP C220 - STORM DRAIN INLET <br />PROTECTION OR COE STD 210). PROTECT EXISTING TRENCH <br />DRAIN IN PLACE. <br />11 CONNECT TEMPORARY FENCE TO EXISTING FENCE. <br />CONNECTION MUST MAINTAIN SECURITY OF THE PORT <br />SITE AT ALL TIMES. <br />1.DEMOLISH EXISTING SECURITY FENCE AS REQUIRED TO <br />COMPLETE THE WORK. PROVIDE TEMPORARY FENCE TO <br />SECURE PORT SITE. CONTRACTOR TO PROVIDE SECURABLE <br />GATE FOR TRANSIT THROUGH PORT DURING <br />CONSTRUCTION ACTIVITIES. TCE FOR ACCESS SHARED WITH <br />PORT GARDNER STORAGE FACILITY PROJECT CONTRACTORS. <br />PORT SITE SECURITY MUST BE MAINTAINED AT ALL TIMES. <br />SEE ADDITIONAL REQUIREMENTS PER SECTION 01 12 16 <br />WORK SEQUENCE. <br />2.WORK AROUND POWER AND GAS UTILITIES MUST BE <br />PERFORMED IN ACCORDANCE WITH PSE AND SNOPUD <br />REQUIREMENTS. COORDINATE CONSTRUCTION ACTIVITIES <br />AND SCHEDULE WITH UTILITY OWNER'S. SEE SECTION 02 01 <br />10 AND SECTION 02 01 20. <br />GENERAL NOTES <br />KEY NOTES <br />LEGEND <br />TCE AREA 1 - TRUCK TRANSIT AREA (OUTSIDE <br />SECURE PERIMETER) 67,508 SF <br />TCE AREA 2 - TRUCK TRANSIT AREA (WITHIN <br />SECURE PERIMETER) 103,625 SF <br />TCE AREA 3 - CONSTRUCTION USE <br />20,248 SF FOR STAGING <br />PE AREA 4 - EXISTING CITY EASEMENT STAGING <br />45,585 SF <br />PE AREA 5 - EXISTING CITY EASEMENT FOR <br />TRANSIT XX SF <br />12/09/2025
The URL can be used to link to this page
Your browser does not support the video tag.