3815_PGSF WMVD Pkg 2_Vol 4-2_03.03.2026_BXWA_Certified
>
Contracts
>
Capital Contract
>
Capital Construction Contracts and Change Orders
>
3815_PGSF WMVD Pkg 2_Vol 4-2_03.03.2026_BXWA_Certified
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2026 2:55:34 PM
Creation date
4/22/2026 2:02:54 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
KLB Construction, LLC
Approval Date
4/22/2026
Council Approval Date
4/8/2026
Department
Public Works
Department Project Manager
Randy Loveless
Subject / Project Title
PGSF West Marine View Drive Storm and Combined Sewer, Package 2 Volume 4.2
Tracking Number
0005222
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1718
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
ASPECT CONSULTING <br />PROJECT NO. AS190583A-08 MAY 21, 2025 FINAL 19 <br /> <br />Tidal study data from nearshore monitoring wells REC7-MW-1, REC7-MW-2, <br />REC7-MW-3, REC7-MW-4, UST68-MW-5, and UST70-MW-2 (Figure 2-8) were <br />determined to exhibit suitable tidal response to allow application of the Ferris (1963) <br />methods. Because Upland Area groundwater’s highest beneficial use is discharge to the <br />East Waterway, it is appropriate to focus the K estimates on the shoreline area. Table 2-2 <br />presents the input data and the resulting K estimates for the six wells. The average <br />(geometric mean) of the K estimates from the two methods represents a best-estimate K <br />value for each well. <br />The estimated K ranges from 5 x 10-4 centimeters per second (cm/sec) at REC7-MW-1 in <br />Unit E to 3 x 10-2 cm/sec at UST70-MW-2 in Unit B 9 (Table 2-2). This K range, and a <br />site-wide geometric mean K of 5 x 10-3 cm/sec from the six wells’ estimates, are <br />considered reasonable for the sandy dredge fill comprising the bulk of the Upland Area fill <br />unit. <br />SLUG TESTING FOR LOG POND FILL AND SAWDUST UNIT <br />Because tidal response was not observed in Log Pond shoreline wells, the tidal study <br />method for estimating K specific to the Log Pond fill could not be conducted, as stated <br />above. Therefore, slug tests were performed to estimate K for subsurface materials in the <br />Log Pond area, in accordance with Aspect (2017b). Slug tests were conducted in wells <br />LP-MW-2, LP-MW-4, and REC6-MW-2 screened in the Log Pond fill, and wells <br />LP-MW-3, LP-MW-5, LP-MW-6, and LP-MW-7 screened across the deep sawdust layer. <br />Except for well LP-MW-2, two or three tests (rising and falling head) were conducted in <br />each well and the average K from the replicate tests were used to represent K for that <br />location. Because of the very long water level recovery during testing of well LP-MW-2, <br />only one test was conducted for that well. A geometric mean K was then calculated for the <br />Log Pond fill and for the sawdust layer hydrostratigraphic units using the respective well <br />estimates. Table 2-3 presents the slug test analysis parameters and results for the Log Pond <br />wells. <br />The geometric mean K for the Log Pond fill is 8 x 10-5 cm/sec, approximately 70 times <br />lower than the Site-wide average K for the dredge fill outside of the Log Pond. The low K <br />is consistent with the generally siltier fill material observed within the Log Pond. <br />2.4.4.2.4 Groundwater Velocity Estimates <br />The K estimates can be used, with measured nearshore tidally averaged hydraulic gradient <br />and estimated effective porosity, to estimate horizontal average linear (seepage) <br />groundwater velocities for the nearshore portion of the Upland Area. A groundwater <br />seepage velocity for the shoreline area is calculated using Darcy’s Law of the form: <br /> v = K * I / ne, where: <br /> v = seepage velocity (feet/year); <br /> K = hydraulic conductivity (feet/year); <br /> <br />9 For purposes of the RI/FS data analysis as described in Section 6.2, the Upland Area is divided into <br />five Units A through E, from south to north (see Figure 2-3).