LEGEND ELECTRICAL DEMOLITION & REMODEL GENERAL NOTES <br /> O FIXTURE TYPE Ny�� <br /> 0 HIGHBAY LIGHT FIXTURE ELECTRICAL CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DEMOLITION AND PHASING PLANS FOR THE SCOPE OF <br /> 01 WALL MOUNTED FIXTURE CORRESPONDING ELECTRICAL DEMOLITION WORK. <br /> ®I COMBINATION EXIT/EGRESS FIXTURE WITH BATTERY PACK FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. W d u \ sue <br /> ©I EGRESS/EMERGENCY FIXTURE W/ BATTERY PACK nn w <br /> REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING W cxi �Or <br /> O LED LIGHT FIXTURE BACK TO THE NEXT ACTIVE OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. <br /> FIXTURE ON EMERGENCY LIGHT CIRCUIT W BATTERY BACK PACK U <br /> Oa / REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE WIRES. <br /> (� SUB-LETTER INDICATES CONTROLLING SWITCH REMOVE ALL UNUSED SURFACE RACEWAYS. rOr <br /> OUTER LAMP(S) ANDEb CONTROLS NINNERITLAMP?S�ONTROLS RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW W <br /> LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. <br /> $ SINGLE POLE SWITCH, +42" <br /> PROVIDE CUTTING, PATCHING FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. I—I <br /> % SUB-LETTER INDICATES FIXTURE CONTROLLED, +42" r, 3 <br /> $p SINGLE POLE SWITCH WITH PILOT LIGHT, +42" INFORMATION ON THE EXISTING INSTALLATION HAS BEEN OBTAINED FROM THE BEST SOURCE AVAILABLE BUT CANNOT <br /> BE GUARANTEED ACCURATE IN ALL RESPECTS. PRIOR TO BID, IT IS THE CONTRACTORS'S RESPONSIBILITY TO VISIT o <br /> $k SINGLE POLE SWITCH WITH KEY-LOCK, +42" THE SITE. VERIFY ALL SUCH INFORMATION AND THOROUGHLY FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. (� <br /> $y THREE POLE SWITCH, +42" DRYWALL PER ARCH <br /> ALL WORKS SHALL BE PERFORMED TO CHANGE THE EXISTING ELECTRICAL INSTALLATION AS SHOWN. INCLUDE AS PART <br /> El PUSH BUTTON, +42" OF THE CONTRACT ALL RELATED WORKS REQUIRED TO OBTAIN THE INDICATED RESULTS. <br /> 4 PUSH BUTTON FOR SHUNT TRIP, +42" ALL EXISTING WIRING, CONDUITS, JUNCTION BOXES AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES IN THE 9-FT HOFFMN 3"X 3" (4" x 4") 2 '� <br /> 0 DIMMER SWITCH, LEVITON IP71OLFZ OR EQUAL AREAS AFFECTED BY THE REMODEL SHALL BE REMOVED AND RELOCATED AS REQUIRED. EXTEND ALL CONDUITS AND WIREWAY TO SPACE ABOVE CEILING. <br /> (ly OCCUPANCY SENSOR/SWITCH LEVITON ODS15-ID. NOTE: SET TO WIRING. <br /> 20-MINUTES DELAY. <br /> Qy 0-10V OCCUPANCY SENSOR & DIMMING SWITCH LUTRON <br /> ALL WORKS ARE TO BE DONE SO AS NOT TO INTERFERE WITH THE WAREHOUSE'S NORMAL OPERATION. ALL WORKS <br /> MS-ZlK <br /> ARE TO BE COORDINATED AND SCHEDULED AS APPROVED BY THE WAREHOUSE MANAGER FOR ELECTRICAL SHUTDOWN, <br /> VOLTAGE <br /> 1WIIR NOTE:ESETACH <br /> TO 20-MINUTES DELAY. PROVIDE LOW CONTINUITY OF SERVICE, ETC. ATTACHMENT RING <br /> VOLTAGE WIRING TO EACH FIXTURE. MAKE ALL FINAL CONNECTIONS 437-7/8" <br /> AS REQUIRED. FIELD VERIFY. COORDINATE AND SCHEDULE WITH OWNER FOR ANY EXISTING ELECTRICAL SERVICE SHUTDOWN, PROVIDE TEMPORARY WHITE 2-GANG BRUSH <br /> m SINGLE PLUG-IN RECEPTACLE, +18" MIN. OR AS NOTED POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. TEMPORARY COVERPLATE <br /> ® DUPLEX RECEPTACLE, +18" MIN. OR AS NOTED POWER SOURCES INCLUDE GENERATOR SET, POWER COMPANY'S TEMPORARY SERVICE HOOKUP, ETC. SPACER/SUPPORT <br /> m ISOLATED GROUND DUPLEX RECEPTACLE, +18" MIN. OR AS NOTED PROVIDE METAL SHEET PAN UNDER ALL FREE STANDING ELECTRICAL PANEL. AS REQUIRED <br /> ISOLATED GROUND FOUR-FLEX RECEPTACLE, +18" MIN. OR AS NOTED <br /> E.C. TO PROVIDE NEW TYPED INDEX FOR EXISTING PANELS AFFECTED BY THIS REMODEL. TURN 'OFF' ALL SPARE SD-1 ON CEILING DECK <br /> ® FOUR-PLEX RECEPTACLE, +18" MIN. OR AS NOTED BREAKERS AND PROVIDE 'SPARE' LABEL IQ EXISTING PANEL PI ON CEILING DECK <br /> ® 208 VOLT RECEPTACLE, +18" MIN. OR AS NOTED COMPLY WITH LATEST NEC AND LOCAL AMENDMENTS NOTE: THIS DETAIL IS TYPICAL FOR ALL ACCESS PENETRATIONS <br /> PLUGMOLD WITH RECEPTACLES, SEE SPECS TO WIREWAY. HEIGHT OF PENETRATIONS ARE SPECIFIED ON <br /> O JUNCTION BOX, SIZE AND TYPE PER CODE PLAN. AN ADDITIONAL PENETRATION AT 8'-9" (IN CEILING EXISTI TRANSFORMER ON CEILING <br /> SPACE) IS TYPICAL FOR ALL CHASES - NO COVERPLATE <br /> m HACR BREAKER IN NEMA ENCLOSURE, COORDINATE W/EQUIPMENT SUPPLIER NEEDED FOR CEILING SPACE PENETRATION. EXISTIN P CEILING DECK a <br /> 0 0 <br /> m' FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER <br /> 0' COMBINATION STARTER/DISCONNECT SWITCH WALL DUCT DETAIL X❑❑ <br /> m' O <br /> NON-FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER OPTICAL EXAM ROOM <br /> HACR BREAKER IN NEMA ENCLOSURE, COORDINATE W/EQUIPMENT SUPPLIER NO SCALE — — <br /> © 2-COMPARTMENT WHITE COLOR POWER POLE, WIREMOLD 25DTP SERIES <br /> 0��^ EXISTING HI BAY LIGHT FIXTURE <br /> Yjp V REMOVE & RELOCATE EXISTING Al BAY LIGHT FIXTURE — — — — <br /> I� H <br /> PANEL: P11 208 / 120 VOLTS 3 PHASE 4 WIRE <br /> 100 A CU BUS M.L.O. 10000 A.I.C. MIN. c <br /> EXISTING TOP FEED SURFACE MOUNT SQ-D NQOD w <br /> PHASE (KVA) CKT.CKT. PHASE (KVA) <br /> CIRCUIT USE A I B C BKR. NO. NO. BKR. A B I C CIRCUIT USE <br /> PLUGMOLD - OPTICAL 1.00 20 1 1 2 20 1 1.08 OPTICAL LIGHTS w <br /> OPT RECEPTION RECEPT 0.72 20 1 3 4 20 1 1.00 PLUGMOLD - OPT- KIOSK N <br /> OPT EXAM ROOM RECEPT 1.08 20 1 5 6 20 1 1.30 OPT RECEPT KIOSK N <br /> OPT EXAM ROOM RECEPT 0.18 20 1 7 8 20 1 2.00 PLUGMOLD - OPT- KIOSK G N N <br /> SUMP PUMP 1.00 20 1 9 10 20 1 SPARE p <br /> WH-10 1.50 20 2 11 12 20 1 SPARE XI <br /> N <br /> 1.50 13 14 15 2 5.00 ERV-1 * <br /> OU-1 1.48 25 2 15 16 5.00 <br /> AREA OF WORK. E <br /> ENLAR D PLAN THIS <br /> 1.48 17 18 20 1 SPARE ro <br /> SHEET. <br /> ROOF RECEPTACLE 0.18 20 1 19 20 20 1 SPARE � <br /> IU-1 2.23 25 2 21 22 20 1 SPARE o <br /> 2.23 23 24 20 1 SPARE o <br /> SPARE 20 1 25 26 20 1 SPARE N <br /> SPARE 20 1 27 28 20 1 SPARE <br /> SPARE 20 1 29 30 20 1 SPARE --- F W <br /> SPACE 31 32 SPACE a --- E- q T.M o <br /> SPACE 33 34 SPACE <br /> O W oo� <br /> SPACE 35 36 SPACE Z q o rn <br /> SPACE 37 38 SPACE - — — a 1 o <br /> SPACE 39 40 SPACE — <br /> SPACE 41 42 SPACE J J Z c �'o <br /> TOTAL PHASE A (KVA) 2.86 10.94 KVA 8.08 x ztIzz <br /> TOTAL PHASE B (KVA) 5.43 11.43 KVA 6.00 �J Q W z F E wz <br /> TOTAL PHASE C KVA 6.29 7.59 KVA 1.30 - cq•� w x <br /> TOTAL CONNECTED LOAD 29.96 KVA 83 A — — — — E Z m�'x a w <br /> w <br /> *ADDED/ REVISED LOAD. PROVIDE BREAKER AS SHOWN. <br /> CJ' <br /> E77:1 w <br /> // <br /> a z <br /> ❑ w <br /> U <br /> L <br /> Q rt <br /> N �I� u)w <br /> � <br /> w a <br /> w <br /> E- 0 <br /> o GT" <br /> 000 0 ❑ W x a x <br /> Z o O w a'w <br /> z 3= `� w <br /> C F Z u cD <br /> x oLL w <br /> I I C.5 <br /> 0 <br /> W <br /> a O <br /> — — a gw <br /> oz <br /> -- Woz <br /> Q \ m3 <br /> �~ o <br /> P11/14 _ Q a <br /> w �w <br /> o <br /> so <br /> w <br /> ERV w oa <br /> L <br /> 0 ---- az <br /> 0 zo <br /> oo <br /> o N <br /> 0 O <br /> ENLARGED POWER — — — — <br /> HVAC PLAN a <br /> SCALE: 1 4 = 1-0 2 O 1 F zz 1 <br /> CD 1� <br /> o � w <br /> N PARTIAL FLOOR PLAN � a <br /> 0 <br /> N SCALE: 1 IB = 1-0 <br /> Y <br />