906 SE EVERETT MALL WAY T MOBILE ANTENNA 2019-09-05
>
Address Records
>
SE EVERETT MALL WAY
>
906
>
T MOBILE ANTENNA
>
906 SE EVERETT MALL WAY T MOBILE ANTENNA 2019-09-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/5/2019 8:51:56 AM
Creation date
8/3/2016 3:45:44 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
906
Tenant Name
T MOBILE ANTENNA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
75
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r SECTOR COLOR ANTENNA MODEL# VENDOR AZIMUTH(TN) MECHANICAL ELECTRICAL RADIATION HYBRID CABLE COAX CABLE HYBRIDCABLE: ' <br /> DOWNTILT DOWNTILT CENTER LENGTH SECTOR xOFCAe�Es LENGTH �seo7NcaeeKaneKwnvNoarH <br /> ALPHA 3 15'-0" aorHe��,wnsr+iNcroNsaon <br /> ALPHA RED HBXX-3319DSA2M ANDREW 80° 0 0 82'-0"AGL BETA 3 15'-0' <br /> SBNHH-iD65C ANDREW 110" 0 0 80'-0"AGL (1�-75-0" (2)7/8"-65'-0" GAMMA 3 15'-0" <br /> DELTA 2 15'-0" <br /> OMEGA 2 15'-0" <br /> BETA GREEN HBXX-3319DS-A2M ANDREW 180' 0 0 82'-0"AGL SIGMA 2 15'-0" <br /> SBNHH-1D65C ANDREW 210° 0 0 80'-0"AGL (1)-220'-0" (2)1-5/8"-220'-0" �� <br /> GAMMA BLUE HBXX-3319DS-A2M ANDREW 340' 0 0 82'-0"AGL <br /> SBNHH-1D65C ANDREW 10' 0 0 80'-0"AGL (1)-75'-0" (2)7/8"-65'-0" (12�FIBER 9�zsiHieonvenveNe.smrenio <br /> DIELECTRICCENTRAL .. INDOOR/OUTDOOR senrae,wnsrr�.r:�ror�vens <br /> DELTA YELLOW HBXX-3319DSA2M ANDREW 140° 0 0 82'-0"AGL MEMBER DISTRIBUTION CABLE <br /> �, <br /> CORRUGATED COPPER 1 (6)6 AWG THHN/THWN <br /> ARMOR ��:::� �:�:� COPPER CONDUCTOR � <br /> OMEGA ORANGE HBXX3319DSA2M ANDREW 250' 0 0 82'-0"AGL �� (2) 18 AWG COPPER PAIR <br /> (2)ARAMID RIPCORDS �� <br /> MDPEOUTERIACKET ����-�- Y�- ' <br /> CORRUGATED <br /> SIGMA PURPIE HBXX-3319DSA2M ANDREW 40° 0 0 82'-0"AGL LAMINATED STEEL TAPE ������ <br /> Architectural <br /> Sol�rtia;ts frou� <br /> SITE LOADING CHART 2 HYBRID CABLE DETAIL <br /> $CALE:N.i.S. 72pp SOUIH ALiON WAY.�270 <br /> CENiENNIAL CO 80I12 <br /> �avi�zsszu���..� <br /> CONNECTORS(TYP) '�"'°' <br /> aepmtl3"�-com <br /> �,� �� SCOPE OF WORK: ANDREW HBXX3319DSA2M ANTENNA: Q <br /> I I � MONOPOLE: DIMENSIONSWxHxD: 22.2"x57.0"X4.9" w � <br /> � ,�} � UNIT WEIGHT: 17.3 KG(38.1 L8S) u <br /> , ___ i� ��f 7���' (6)(E)TMBXX-651&R2M ANTENNAS TO BE REMOVED CONNECTOR: 4 X 7/16 DIN PEMALE <br /> ,�/' � <br /> (3)(E)SBNH-1 D65C ANTENNAS TO BE RELOCATED 3 � <br /> (6)(P)HBXX-3319DS-A2M ANTENNAS TO BE INSTALLED FREQUENCY: 1710-2170 MHz <br /> ELECTRICAL TAPE (3)(P)FRIG'S TO BE INSTALLED POLARIZATION: t 45° <br /> (1 LAYER) (3)(P)FHFB'S TO BE INSTALLED GAIN: 20.4-20.8 dBi o <br /> STEP 1 STEP 2 (24)(P)ECC7920-VPUB DIPLEXERSTO BE INSTALLED AZIMUTH B.W.: 34°-36° � <br /> (3)(P)BALLASTED FRAMES VSWR: 1.5/14 <br /> (3)(E)FRIG'S TO BE RELOCATED MAX INPUT POWER: 400 WATTS <br /> BUTYL TAPE (3)(E)FRLB'S TO BE RELOCATED ELEVATION: 5.0°t 0.7° <br /> (ALSO KNOWN AS T-MOBILE EQUIPMENT AREA: <br /> MASTIC,TAFFY TAPE) (3)(P)FSMF'S TO BE INSTALLED <br /> � � (2)(P)FBBCS TO 8E INSTALLED <br /> (2)(P)FBBA'S TO BE INSTALLED <br /> 4.9" <br /> 0 <br /> yy��;��; ���_ � �o��a� o � <br /> � <br /> z2.z� � <br /> STEP 3 , <br /> o ; <br /> ELECTRICAL TAPE:3 LAYERS WITH 2"TAPE AND 3 LAYERS <br /> IN 3/4"TAPE(ALL WITH MINIMUM 50%OVERLAP).ALL f <br /> TAPE ENDS SHALL BE CUT(DO NOT S7RETCH).COAT `�� � 3 SCOPE OF WORK 4 ANTENNA DETAIL SCALE:N.T.S. <br /> WITH 3M SCOTCHKOTE SPRAY SEALER. � t�'�'`If,��- <br /> � r <br /> �4 4 1-�.`���.� ^1 \9664 REGISiERED <br /> . , iF'�"N. 1 > ARCHRECi <br /> ��--��_ �� y� � NOTES: � <br /> — --�� �'� <br /> � � ,� f'�� � � � ���� � ��} 1. ALL COAXIAL CABLE CONNECTIONSTO BE WEATHER PROOFED. Ker+r+�rH MecencKeN <br /> — ——-I_ ...�,�f,Ir�_ �%i �.�.�'�Gtl�.i SiATE OF WASHINGTON <br /> ,'.{/��}�; 2. CONTRACTORTODIPCABLESANDIUMPERSWHERENECESSARY <br /> �r�;;k�� 0�/�7/zo�7 <br /> 1--=� 3. TAGGING: ,,.� <br /> STEP 4 1'i.'I ALLCOAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. e,, <br /> � <br /> 4. COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END CABLE OF)UMPERS AS <br /> CLOSE TO EACH END AS POSSIBLE.(NOT TO WTERFERE WITH WEATHERPROOFING). �re r,nM=_: <br /> 1. ALLCOAXIALCABLECONNECTIONSTOBEWEATHERPROOFED. EVERETTMALL <br /> 5. COAXIALCABLESPECIFICATIONSREQUIRECABLESUPPORTEVERY3'-0"ONCENTER.CONTRACTOR PARK <br /> 2. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY SHALL SUPPLY SUPPORTS AS REQUIRED TO MEETTHIS RE�UIREMENT. SEO�bHHA <br /> s�re,,00e=_ss�. <br /> 3. TAGGIN�: 6. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY 906 SE EVERETf MA LL W Y <br /> ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO INDICATE THE ANTENNA SECTOR. FROM CONNECTION.(SEE STEP 4). EVERETT,WA 98208 <br /> 4. COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH END CABLE OF JUMPERS AS 7. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR�UAD POLES AND TMA'S. <br /> CLOSE TO EACH END AS POSSIBLE.(NOTTO INTERFERE WITH WEATHERPROOFING). P�o;=��r+�..m�oe� <br /> TM O 16050.0 <br /> 5. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY3'-0"ON CENTER.CONTRACTOR SHALL <br /> SUPPLY SUPPORTS AS REQUIRED TO MEET THIS REQUIREMENT. 5°ee'�:°'"e <br /> 6. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP MOVES WATER AWAY R F <br /> FROM CONNECTION.(SEE STEP 4). DETA ILS <br /> 7. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR�UAD POLES AND TMA'S. sr�eei r<���e� - � <br /> 5 COAXIAL CABLE WEATHERPROOFING DETAILS SCALE:N.T.S. (� COAXIAL CABLE WEATHERPROOFING NOTES 7 NOT USED R F— I <br />