Laserfiche WebLink
• <br /> 'L co <br /> LANDLORD SIGNATURE . 4; ` ' <br /> IEXPIRES 11/2.0/8 <br /> IT ISA VIOLATION OF LAW FOR ANY PERSON,UNLESS THEY <br /> ARE ACTING UNDER THE DIRECTION OF A LICENSED <br /> PROFESSIONAL ENGINEER.TO ALTER THIS DOCUMENT. <br /> ANTENNA SCHEDULE-FINAL CONFIGURATION .11 . Mobile •• <br /> SECTOR EXISTING/ ANTENNA RAD DIMENSIONS WEIGHT TRANSMISSION CABLE <br /> (COLOR) POSITION NEW MANUFACTURER ANTENNA MODEL PORT AZIMUTH CENTER (LxWxD) (LBS) 19807 NORTH CREEK PARKWAY NORTH <br /> QTY. LENGTH SIZE TYPE <br /> BOTHELL,WA 98011 <br /> Ai EXISTING ANDREW HBXX-3319DS-A2M QUAD 80° 86.4' 57.0"x 22.2"x 4.9" 38.1 (2) 15' TBD FIBER <br /> _ JUMPER ANTENNA AND COAX GENERAL NOTES: <br /> ALPHA (1) 15' TBD FIBER JUMPER 1. ALL ANTENNA AND COAXIAL ANTENNA CABLE TO BE FURNISHED BY T-MOBILE AND <br /> (RED) 4 NEW COMMSCOPE FFHH-65C-R3 OCTA 110° 84.8' 95.9"x 25.2"x 9.3" 127.6 (1) 100' 1.5'0 HIGH CAP HCS INSTALLED BY CONTRACTOR. Technology' Associates <br /> 2. COAX COLOR CODING:ANTENNAS TO BE NUMBERED IN A CLOCKWISE MANNER <br /> FROM TRUE NORTH AND COLOR CODED AS FOLLOWS. PNW MARKET OFFICE <br /> 650 SOUTH ORCAS STREET,STE.R-103 <br /> ' , 3. THE ABOVE COAX COLOR CODING APPLIES TO SECTORIZED SITES.FOR OMNI SEATTLE,WA 98108 <br /> 81 EXISTING ANDREW HBXX3319135-A2M QUAD 220° 86.4' 57.0"x 22.2"x 4.9" 38.1 (2) 15' TBD FIBER SITES,USE THE ATO,BTO,&GTO COLOR CODES ONLY. <br /> JUMPER <br /> 4. COAX SHALL BE TAGGED WITH COLOR CODING AT(2)PLACES USING 1"WIDE <br /> BETA (1) 15' TBD FIBER JUMPER WEATHER PROOF COLORED VINYL TAPE AT THE FOLLOWING LOCATIONS: <br /> B2 <br /> (GREEN) NEW COMMSCOPE FFHH-65C-R3 OCTA 250° 84.8' 95.9"x 25.2"x 9.3" 127.6 (1) 225' 1.5'0 HIGH CAP HCS •#1-AT ANTENNA CONNECTION <br /> •#2-AT ENTRY TO EQUIPMENT CABINET Technology Associates <br /> 5. RUN COAXIAL CABLE WITH MINIMUM 12"SLACK&12"FROM EDGE OF EQUIPMENT <br /> CABINETS,ACROSS WAVE GUIDE BRIDGE(IF APPLICABLE),UP TO TOWER LEG(IF ARCHITECTURE&ENGINEERING <br /> APPLICABLE),&DISTRIBUTE TO EACH ANTENNA DEVICE.FURNISH AND INSTALL A 2851 CAMINO DEL RIO SOUTH,STE.200 <br /> CI EXISTING ANDREW HBXX3319DS-A2M QUAD 340° 84.7' 57.0"x 22.2"x 4.9" 38.1 (2) 15' TBD FIBER MINIMUM OF(3)GROUND KITS PER COAXIAL CABLE ACCORDING TO ELECTRICAL SAN DIEGO,CA 92108 <br /> JUMPER DRAWINGS.VERIFY NUMBER OF ANTENNAS,CABLE,&CABLE DIAMETER WITH <br /> PROJECT MANAGER. <br /> GAMMA (1) 15' TED FIBER JUMPER <br /> (BLUE) © NEW COMMSCOPE FFHH-65C-R3 OCTA 10° 83.1' 95.9"x 25.2"x 9.3" 127.6 (I) 75' 1.5'0 HIGH CAP HCS 6. ALL COAXIAL CABLE CONNECTIONS TO BE WEATHER PROOFED. <br /> 7. CONTRACTOR TO DIP CABLES AND JUMPERS WHERE NECESSARY. <br /> 8. TAGGING: <br /> ' •ALL COAXIAL CABLES TO BE MARKED WITH COLOR CODED TAPE TO 0 05/14/2018 L700-CMP4-4X2 10016CD MGM <br /> DELTA O EXISTING ANDREW HBXX3319DSA2M QUAD 140° 88.4' 57.0'x 22.2'x 4.9' 38.1 (2) 15' TED FIBER INDICATE THE ANTENNA SECTOR. <br /> /YELLOW) JUMPER •COLORED ELECTRICAL TAPE SHALL MARK EACH END OF CABLE AND EACH A 04/09/2018 L700-CMP44X299%CD MGM <br /> EPSILON O Et EXISTING ANDREW HBXX3319DSA2M QUAD 280° 84.7' 57.0"x22.2"04.9" 38.1 (2) 15' TED FIBER END OF JUMPERS AS CLOSE TO EACH END AS POSSIBLE.(NOT TO A 02/21/2018 ISSUED FOR75%CD REVIEW CMB <br /> (WHITE) JUMPER INTERFERE WITH WEATHERPROOFING.) REV DATE DESCRIPTION BY <br /> ZETA <br /> (PURPLE) F1 EXISTING ANDREW HBXX-3319DS-A2M QUAD 40° 86.4' 57.0"x 22.2"54.9" 38.1 (2) 15' TED FIBER 9. COAXIAL CABLE SPECIFICATIONS REQUIRE CABLE SUPPORT EVERY 3'-0'ON <br /> JUMPER CENTER.CONTRACTOR SHALL SUPPLY SUPPORTS AS REQUIRED TO MEET THIS <br /> REQUIREMENT. <br /> NOTE: SE01688A <br /> I. ANTENNA CLEARANCE AND MOUNTING TO BE FIELD VERIFIED PRIOR TO CONSTRUCTION WITH FINAL ANTENNA SPECIFICATIONS,MOUNTING HARDWARE,AND RF DESIGN. 10. VERTICAL CONNECTIONS SHALL BE TAPED FROM THE BOTTOM UP SO OVERLAP <br /> 2. CD IS BASED ON REDS VERSION:4.1 DATED:03/12/2018. MOVES WATER AWAY FROM CONNECTION(STEP 9). <br /> 11. PROVIDE HEAT SHRINK IN PLACE OF TAPE FOR QUAD POLES AND TMA'S.HEAT EVERETT MALL <br /> W 'C <br /> SHRINK SHALL BE ANUSA"WITH ADHESIVE. <br /> W <br /> W PARK <br /> 0 i am�gar <br /> W ELECTRICAL TAPE:3 LAYERS WITH 2"TAPE AND 3 �MU 906L1 SE EVERETT MALL WAY <br /> LAYERS IN 0rj/ I 3/4"TAPE(ALL WITH MINIMUM 50% r EVERETT,WA 98208 <br /> O OVERLAP).ALL TAPE ENDS SHALL BE CUT(DO NOT �IIlII <br /> D CONNECTORS(TYP.) ELECTRICAL TAP BUTYL TAPE(ALSO KNOWN STRETCH).COAT WITH 3M SCOTCHKOTE SPRAY y8 <br /> u (1 LAYER) AS MASTIC.TAFFY TAPE) SEALER J/ <br /> 2 11111El/l111il110*1l I. . 1" 1"ie <br /> 2" 2" 4" pror4" ROOFTOP <br /> ��---- 2/a ---Im �Aio/%%i,�'//////ii�� ' Al <br /> 4,,,r4.- 46046-74.1%166,- AN Ir fdiFfro/re"Arzaror TAr <br /> Are Ai Ass--,4 .44FAIr ArANIF- pr 00 <br /> IF <br /> 0 STEP 1 STEP 2 STEP 3 STEP 4 I Arj <br /> F mu /31, <br /> COAXIAL CABLE WEATHERPROOFING <br /> a <br /> a <br /> co <br /> •0 <br /> JURISDICTION APPROVAL STAMP <br /> DEPARTMENT FOR INGO C USE <br /> FOR <br /> DEPARTMENT FOR BUILDINGbCONSTRUCTION <br /> 2 <br /> u SHEET TITLE <br /> 0 <br /> - RF DETAILS <br /> 0 <br /> 1 <br /> J <br /> a <br /> a <br /> Hz <br /> SHEET NUMBER <br /> 0 RF- 1 <br /> I- <br /> RF DETAILS SCALE I 1 <br />