My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5107 EVERGREEN WAY 2016-08-04
>
Address Records
>
EVERGREEN WAY
>
5107
>
5107 EVERGREEN WAY 2016-08-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2016 10:24:20 AM
Creation date
8/4/2016 10:24:19 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
5107
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> SPECIFICATIONS <br /> Gas Model No. EL180UH045E36A EL180UH070E36B EL180UH090E48B <br /> Heating Model No.-Low Nox EL180UH045XE36A tEL180UH070XE36B \ EL180UH090XE4813 <br /> Performance 'AFUE \ 80% X 80% 80% <br /> Input-Btuh 44,000 / 66,000 / 88,000 <br /> Output-Btuh 36,000 53,000 / 72,000 <br /> Temperature rise range °F 15-45 40-70 35-65 <br /> Gas Manifold Pressure(in.w.g.) 3.5/10.0 .5/10.0 3.5/10.0 <br /> Nat. Gas/LPG/Propane <br /> High Static-in.w.g. 0.50 0.50 0.50 <br /> Connections Flue connection-in. round 4 4 <br /> in. Gas pipe size IPS \ 1/2 1/i 1 <br /> Indoor Wheel nom.dia.x width-in. i '8 10 10 10, 10 <br /> Blower Motor Type DC B' shless DC B ushl- s DC a us i less <br /> Motor output-hp 1 ' 1/2 3/4 <br /> Tons of add-on cooling 1.5- 1.5-3 2.5-4 <br /> Air Volume Range-cfm 350-130 95-1415 50-178 <br /> Electrical Voltage 120 vo s-60 hertz-1 . ase <br /> Data Blower motor full load amps 6.8 6.8 8.4 \\ <br /> Maximum overcurrent protection 15 15 15 <br /> Shipping Data lbs.-1 package / 111 127 142 <br /> SPECIFICATIONS <br /> Gas Model No. EL180UH090E60C EL180UH110E60C EL180UH135E6OD <br /> Heating Model No.-Low Nox --- EL180UH110XE60C --- <br /> Performance 'AFUE 80% / 80% 80% <br /> Input-Btuh 88,000 110,000 132,000 <br /> Output-Btuh 72,000 90,000 107,000 <br /> Temperature rise range-°F 30-60 35-65 30-60 <br /> Gas Manifold Pressure(in.w.g.) 3.5/10.I 3.5/10.0 .5/10.0 <br /> Nat. Gas/LPG/Propane <br /> High Static-in.w.g. 0.5r 0.50 0.51 <br /> Connections Flue connection-in. round 4 <br /> in. Gas pipe size IPS 2 1/2 2 <br /> Indoor Wheel nom.dia.x width-in. 11 / x 10 11-1/2 x 10 11 <br /> Blower Motor Type D• Brus less DC Brushless D Brus less <br /> Motor output-hp 1 1 1 <br /> Tons of add-on cooling 3-5 3-5 3.5-5 <br /> Air Volume Range-cfm 990-2290 920-2315 1140-249 <br /> Electrical Voltage 120 volts-60 hertz-1 phase <br /> Data Blower motor full load amps 10.9 10.9 10.9 <br /> Maximum overcurrent protection 15 15 15 <br /> Shipping Data lbs.-1 package 152 160 j 178 <br /> NOTE-Filters and provisions for mounting are not furnished and must be field provided. <br /> 1 Annual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations.Isolated combustion system rating for non-weatherized fumaces. <br /> INSTALLATION CLEARANCES - INCHES(MM) <br /> UPFLOW POSITION HORIZONTAL POSITION <br /> Vent Type Type B1 Type C Vent Type Type B1 Type C <br /> Sides 0(0) '0(0) End '2 '2 <br /> Rear 0(0) 0(0) Rear 0(0) 0(0) <br /> Top 1 (25) 1 (25) Top '0(0) 1 0(0) <br /> Front 2-1/4(57) 2-1/4(57) Front 2-1/4(57) 2-1/4(57) <br /> Front(service/alcove) 24(610) 24(610) Front(service) 24(610) 24(610) <br /> Floor Combustible Combustible Floor Combustible Combustible <br /> Flue 1 (25) 6(152) Flue 1 (25) 6(152) <br /> NOTE—Air for combustion must conform to the methods outlined in the National NOTE—Air for combustion must conform to the methods outlined in the National <br /> Fuel Gas Code(NFPA 54/ANSI-Z223.1). Fuel Gas Code(NFPA 54/ANSI-Z223.1). <br /> NOTE—In the U.S.flue sizing must conform to the methods outlined in the NOTE—In the U.S.flue sizing must conform to the methods outlined in the <br /> current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable current National Fuel Gas Code(NFPA 54/ANSI-Z223.1)or applicable <br /> provisions of local building codes. provisions of local building codes. <br /> 1 Left side requires 4 in.if single wall vent is used on 14-1/2 in.cabinets,2 in.on 1 Line contact installation permissible between jacket top or sides and building <br /> 17-1/2 in.cabinets. joists. <br /> ELI80UHE/Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.