� 3DPE7A, 3DPE8A, 3DPE9, _JPF1 thru 3DPF6, 5AE82,
<br /> Oayton Operating InstruRions and Parts Manual 5AE83, 6W2N3 thru 6WZN9, 6VYZP0 and 61NZP7
<br /> Dayton� In-Line Cabinet Ventilators
<br /> Assembly (COntinued) into consideration betore installation, recommended over metal ducnvork
<br /> �� � l. For 6ert performance,choose a for reducing fan noise, refer to
<br /> Er � •.�•• , location with the sliortest possible Figure 72.Wliere metal duct is used,
<br /> �� � duct run and minimum number of sound transmission can be reduced
<br /> C elbows. Do not mount intake grille with flexible duct connedions
<br /> C u near woking equipmeot,as shown 6et�veen the fan and the duct, refer
<br /> in Figure 9. to Figurc 13.
<br /> Flgure6—Knockout - - - �- - - . n..o,Mcs,.,�,,...
<br /> 3. Check ductwork to see if the fan's ,.,..�.�:,', �.� . /
<br /> discharge requires rotation i�om
<br /> horizontal to venical discharge, %�r ,��\ __ —=--
<br /> shown in Figutc 7. � - , t I
<br /> i � i �
<br /> �
<br /> ,�- I .� � �i I
<br /> .c. �
<br /> , �(�^� i - +"�J��� ' Flgure9-45°MountlngLocatlon figurelI—FlexibleDuRCannoctlons
<br /> `, '`',' � � 2. Attath adjustable mounting brackeu �d
<br /> Figure 7—Ductwork to fan, but leave the screws loose � c�� • � -
<br /> 4. Singlewide and doublewide models until proper hvighi is determined, ,,,,,,�
<br /> can be rotated from horizontal to shown in Figure 10. �
<br /> vertical discharge To rotate from o"""`�i°° "0^aw
<br /> artanPetl la adapl Oucme�y
<br /> horizontaltovcrticaldischarge, lomoftmounnnp/ � �
<br /> conamone i ��
<br /> remove the two svews holding �, _ -
<br /> the power assembty in,and pull ^ z ''
<br /> power assembly out. Rotate ✓� y
<br /> power atsembly 180 degrees and Figure 10—Attaching UraJcets ��st..
<br /> put back into fan,Use the same 3. Installation of duchvork is critical to F(gure t3—sound and tocation
<br /> screws to reattach powei assemhly the performance ot the fan, shown 5. Slide ductwork over the fan's
<br /> to fan housing.Flip fan over and in Figure 11.Straight ductwork discharge collar and securely attach
<br /> remove the four screws holding (1)or ductwork that turns in the it with sheet metal screws.Make
<br /> the discharge duR and damper same direRion as the wheel(2)is sure thc screws do not interfere with
<br /> assembly. Exchange the assembly recommended.Ductwork turning damper operation.Check damper to
<br /> with plate mounted on top of fan, opposite the whecl direction(3)will make sure it opens ircely.
<br /> showii in Figure R. cause turbulence and back pressure wIRE THE FAN
<br /> � resultin m oor erformance.
<br /> 9 � P p 1. Remove wiring cover. Using proper
<br /> r�.� ' i-� �� wire connectors,wire the fan as
<br /> �. ' I -� � shown in Figure 14.
<br /> ',.� ! ....'t.._....
<br /> ^v°^. --......:.. ; o �
<br /> : �no�oe� ' � �'`
<br /> � � ' .:.....:........ 'rt' Bla ue s ' ot
<br /> -. ckw i 'H
<br /> . � White wire is"Neut�al" Q_���
<br /> (((��� � � �� r� :'•�o�m i Green wire is"Ground" �� -�
<br /> �� . �. ... � ,.� �.
<br /> '...� Figure 14—Prvper Wiring
<br /> Figure 8—Rotating�ischorge : �� i NUTE:Mal:e sure motor votta e a rees
<br /> Installation ��'�n w�ih owersourcevolta e. 9 9
<br /> Flguretl—Uuchvorklnstallation P 9
<br /> NOTE:In critical sound installationz,the 4. For low sound applications, 2, Push all wiring into thc unit's covcr
<br /> location of these fans must be taken fiberglass duRboard is and replace wiring cover. ,�
<br /> � ��
<br /> 4 �
<br />
|