<br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to(a)to
<br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-4613-900.If plan review is
<br /> required,select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been provided
<br /> with this permit application.
<br /> *
<br /> If item(a)-(ii,iii,or v)is selected,the work must aag comply with section(a)-(vii).See arrow fiow chart below.
<br /> (3)Electrical plan review.
<br /> 0 (a)Electrical plan review is not required for:
<br /> (i) Low voltage systems;
<br /> 4-0 (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project;
<br /> (iii)Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder
<br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder.
<br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system
<br /> 0 does not include:
<br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F);
<br /> (B)An essential electrical system defined in NEC 517.2;or
<br /> (C)A required fire pump system.
<br /> 4-1:1 (v) Modifications to existing electrical installations where all of the following conditions are met:
<br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed •
<br /> 250 volts or for lighting circuits not exceeding 277 volts to ground;
<br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F);
<br /> (C)Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2;
<br /> and
<br /> (D)Service or feeder load calculations are increased by 5%or less.
<br /> L
<br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total
<br /> rating of 9600 watts or less.
<br /> (vii)For installations In(a)(fi),(Iii),and(v)of this subsection to be considered,the following must be available
<br /> —*I:1 to the electrical inspector before the work is initiated:
<br /> (A)A clear and adequate description of the project's scope;
<br /> (B)A load calculation(s);
<br /> (C)What the load changes are,providing both before and after panel schedules as needed;and
<br /> (0) Provide information showing that the service and feeder(s)supplying the panel(s)where the work is
<br /> taking place has adequate capacity for arty increased load and has code compliant overcurrent protection
<br /> for that supply.
<br /> NOTE: Electrical plan review is not required for"Medical,dental,and chiropractic clinic"of which is a clinic or
<br /> © physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more,per section
<br /> (1)(c)(xii).
<br /> (b)Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care
<br /> occupancies defined in this chapter.
<br /> 0 (c) If a review is required,the electrical plan must be sUbmitted for review and approval before the electrical work is began.
<br /> to are':90
<br /> 1.01#4-RPP:
<br /> H4a#1. iis6aiOike#4eil 04
<br /> Heattli,'rl+erso F Case i "giN.4 0.40* •**+�: **0..0 y.* *O#-. seM ty_oc herFaca.hies
<br /> fOg' .01ttevieW
<br /> Nospiitar kis Other .t
<br /> ).0.!'ti mol
<br /> eardiR home - Ses
<br /> 01S-0 aet Yes
<br /> �
<br /> orivate-adcohatism..hosittit yes ; y ii .
<br /> vete. ?7 f ri t txo p€a.�.
<br /> Pria f,d d 4 .ta
<br /> Miter*home: Erg *:t:ity 4tttl.kWKty da' cftteaf sg "
<br /> Yes iri*regu1re pian reyleantonfac
<br /> 4xrati , types fat
<br /> 0.ta q 4ef saciiity zy. r `ew2d.byti�e,dep rtm�rnt
<br /> * t rien.ism, *twine..' ,des
<br /> 'itdecit ;treatirtentfac#tity; S'es
<br /> til a>Sci`d.seri'ice:fa1ity .,44j
<br /> *Mt resici'eattlaTlreMbitititian: ' V.es
<br /> center PERMIT# Page 2 of 3