My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1321 COLBY AVE BASE FILE 2021-01-07
>
Address Records
>
COLBY AVE
>
1321
>
BASE FILE
>
1321 COLBY AVE BASE FILE 2021-01-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/7/2021 1:47:50 PM
Creation date
8/17/2016 10:49:41 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
1321
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
144
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stantec <br /> May 30,2017 <br /> Mike Bearda <br /> City of Everett <br /> Engineering/Public Services <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> Subject: PRMCE A-Wing Switchboard Replacement <br /> Responses to Electrical Plan Review Comments <br /> Dear Mike, <br /> Below are responses to the plan review comments that I reviewed with Steve in your <br /> office on the phone on May 23,2017. Enclosed is revised drawing E8.21 that reflects <br /> the necessary changes to the design. <br /> 1. The specifications for the switchboards for the project(Section 262413) <br /> requires that any breakers 1200A and larger be provided with a manual <br /> switching means to override delay in instantaneous trip sensing elements to <br /> 4100194th St SW reduce the arc flash hazard on the load side of the circuit breaker in <br /> Suite 400 accordance with NEC 240.87(B). <br /> Lynnwood,Washington 2. The current design for the connection to Elevators#2 and#3 includes a <br /> 98036-4613 400A-3P breaker and#350MCM conductors. After review of this condition, <br /> we believe that it does comply with the NEC. Each of these elevators is 28hp <br /> 206-667-0555 <br /> 800-667-0610 at 208-volts,3-phase(30hp is 88amps). Per NEC 620.61(B)(1),the overload <br /> 206-667-0554 protection for these two elevators shall be permitted to be in accordance with <br /> NEC 430.33. Further,Table 430.52 allows the overload protection to be up to <br /> www.stantec.com 800% of the full load current. Our expectation is that the breaker feeding <br /> these elevators was oversized to allow for the expected in-rush current. <br /> 3. We have revised the drawing to show a 500A-3P breaker to feed the existing <br /> 30hp fire pump. This complies with NEC 695.4(B)(2)(a)(1)and Table <br /> 430.7(B). The existing conductor size at#3/0 is adequate to supply the fire <br /> pump in accordance with NEC 695.6(B)(1). <br /> 4. Enclosed is the current load calculation information for Providence Everett's <br /> Colby Campus. This project is not adding load to the A-Wing Main <br /> Switchboard so these numbers reflect the current loads on Bus#3,Bus#4 <br /> and Bus#5. <br /> Please review this information and let me know if you have any questions or wish to <br /> discuss further. <br /> Sincerely, <br /> tAANYA144V6-411— <br /> Maureen D.Jackson,PE <br /> Principal,Electrical <br />
The URL can be used to link to this page
Your browser does not support the video tag.