�. TMNE®
<br /> XL95 -Two Stage
<br /> Yard 7b Stop A73ane.
<br /> Table FUR-3-A—Direct/Non-Direct Vent,Upflow/Horizontal Left Condensing Gas Furnace(115/1/60) 0-
<br /> Airflow Flue Uncrated Shipping m
<br /> CD
<br /> Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter**
<br /> Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes t].
<br /> TUH2BO60A936VA 3 57,600 37,440 96.0 2,21/2,3 ® 40 x 171/2 x 28 150 15 14 x 25 x 1
<br /> T1_11121308OA942VA 31/2 76,800 49,920 96.0 2,21/2,3 O 40 x 171/2 x 28 158 15 17 x 25 x 1
<br /> cn
<br /> TUH2C100A948VA 4 96,000 62,400 96.0 21/2,3 O 40 x 21 x28 171 20 20 x 25 x 1
<br /> TUH2D120A960VA 5 115,200 74,880 96.0 3 O 40 x 241/2 x 28 205 20 24 x 25 x 1
<br /> rt
<br /> L95 Direct/
<br /> n-Direct Vent Table FUR-3-B—Direct/Non-Direct Vent,Downflow/Horizontal Right Condensing Gas Furnace(115/1/60)
<br /> Airflow Flue Unrated Shipping
<br /> Unit In Output(Btuh) ICSO Size Ignition Dimensions(in.) Weight Max Filter"
<br /> 'BeModel No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (lbs.) Fuse* Sizes
<br /> TDH2BO60A936VA 2 57,000 37,060 95.0 2,21/2,3 O 40 x 171/2 x 28 155 15 (2)14 x 20 x 1
<br /> TDH2BO80A942VA 31/2 76,000 49,400 95.0 2,21/2,3 O 40 x 171/2 x 28 168 15 (2)14 x 20 x 1
<br /> TDH2C100A948VA 4 95,000 61,800 95.0 21/2,3 O 40 x 21 x 28 185 20 (2)16 x 20 x 1
<br /> TDH2D120A960VA 5 115,200 74,880 96.0 3 O 40 x 241/2 x 28 206 20 (2)16 x 20 x 1 (D
<br /> (D Isolated Combustion System. 0
<br /> S
<br /> ®Silicon Nitride.. CD
<br /> * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. '•
<br /> **Filters are not shipped with furnace.
<br /> KL95 Direct/
<br /> )n-Direct Vent
<br /> XR95 - Single Stage
<br /> Table FUR-3-C—Direct/Non-Direct Vent,Upflow/Horizontal Left Condensing Gas Furnace(115/1/60)
<br /> Airflow Nominal Flue Uncrated Shipping
<br /> Unit In Output ICS(D Size Ignition Dimensions(in.) Weight Max Filter**
<br /> Model No Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes CL
<br /> TU H 1 B040A9241 A 2 38,000 95.0 2 21/2 3 40 x 171/2 x 28 139 15 17 x 25 x 1 O
<br /> 0
<br /> TU H 1 B060A9361 A 3 57,000 95.0 2,21/2 3 ® 40 x 171/2 x 28 150 15 17 x 25 x 1 D
<br /> TUH1608OA9421 B 31/2 73,150 95.0 2,21/2,3 O 40 x 171/2 x_28_ 158 15 17 x 25 x 1
<br /> TUH1C080A9601A 5 76,000 95.0 3 ® 40 x 21 x 28 171 20 20 x 25 x 1 O
<br /> woTUHlClOOA9481A 4 92,150 95.0 3 ® 40 x 21 x 28 171 20 20 x 25 x 1 W
<br /> R95 DirecTUH1 Dl OOA9601 A 5 92,150 95.0 3 ® 40 x 241/2 x 28 197 20 24 x 25 x 1 ,C
<br /> n-Direct Vent TUH1 D120A9601 A 5 104,500 95.0 3 O 40 x 241/2 x 28 205 20 24 x 25 x 1
<br /> Table FUR-3-D—Direct/Non-Direct Vent,Downflow/Horizontal Right Condensing Gas Furnace(115/1/60)
<br /> Airflow Nominal Flue Uncrated Shipping
<br /> Unit In Output ICsO SizeIgnition Dimensions(in.) Weight Max Filter**
<br /> Model No Tons (Btuh) AFUE (in) Device H x W x D (lbs.) Fuse* Sizes
<br /> TDH1 B040A9241 A 2 38,00 95.0 2,21/2,3 O 40 x 171/2 x 28 155 15 (2)14 x 20 x 1
<br /> TDH1 B065A9421A 31/2 57,04 95.0 2,21/2,3 ® 40 x 171/2 x 28 168 15 (2)14 x 20 x 1 0
<br /> TDH 1 C085A9481 A 4 76,000 95.0 21/2,3 O 40 x 21 x28 185 20 (2)16 x 20 x 1
<br /> TDH1 D110A9601A 5 104,500 95.0 21/2,3 O 40 x 241/2 x 28 206 20 (2)16 x 20 x 1 n
<br /> O Isolated Combustion System. 0
<br /> ®Silicon Nitride
<br /> * Information subject to change.Please confirm with current Product Data/Service Facts for current factory production. 0
<br /> :R95 Direct/ •*Filters are not shipped with furnace. a
<br /> n-Direct Vent
<br /> 0
<br /> m
<br /> (n
<br /> (D
<br /> (n
<br /> 0 I.
<br /> complete equipment/combination selections, cn
<br /> allation instructions and warranty information, Effective 1/1A5
<br /> ase refer to Product Data/Ratings and/or Installers
<br /> des and Limited Warranty Handbooks. FUR-3 22-8301-28 I j
<br />
|