3/8/2016 Page 1 <br /> City of Fve►•ett <br /> �:::16:29PrYI <br /> INSPECTION ACTIVITY REPORT <br /> Permit No. CW1209-002 Site Address 2711 MAPLE ST UNIT B <br /> Applied 9/24/2012 Applicant Lot <br /> Approved 11/9/2012 Owner FLAKE DAVID Block <br /> Issued 11/20/2012 Contractor OWNEFt Tract <br /> Parent Permit No. W0709-007 Description INTERIOR R�;MODEL <br /> Notes REYAIR KO'1"1'1:N WOOD WALLS IN LIVINU ROOiv�NEW SILi.PLA"1'L;NGW KI'CCH�N& <br /> BATHROOM-ADD CONCRET�SLAB FLOOR IN LIVING ROOM(INTF,RIOR) <br /> Scheduled Comnleted Tvne Insnector Result Remarks Insqector's Comments <br /> 1/2/2013 Consultation SDP Re groimdwork,see Discussed mcthods and materials for <br /> notcs bathroom&laundry room <br /> 1/4/2013 1/4/2013 PlbgGrWork SDP Approval See notes Grou��dwork OK as noted <br /> 1)Wrap all pipes that will come in contact <br /> witli concrcte-plastic wrap,foram wrap, <br /> etc. <br /> 2)Cap off all pipe openings to prevent dirt <br /> and concrete form entering. <br /> Call for above floor when ready. <br /> 1/10/2013 StructSlab DWF Unable to inspect, No plans/permits on site 8:50 a.m. <br /> see notes No p]anJpermits on site2:30 p.m. <br /> 1/11/2013 1/11/2013 StructSlab TMB Corr Reqd See notes 1)Some portions ofthe exterior walls are <br /> below the exterior grade and aze not of <br /> rot-resistant materials. <br /> 2)No provisions for insulation of the <br /> perimeter of slab are provided(see pla�i). <br /> 3)Center wall rotted and deteriorated at sill <br /> and base of wa1L <br /> 2/5/2013 2/5/2013 Foundation TMB Approval See Notes Complete perimiter slab insulation as <br /> discussed <br /> OK tp place concrete <br /> 9/9/2013 9/9/2013 GasPiping DXW Corr Reqd See nptes Install gas pipe to manufacturer spec. Hot <br /> water tank to be electric. Heater in front <br /> ro��n�n�ust havc combuslion air-(ur cvcry <br /> 1000 btu,50 cu n oPcombustion air,or go <br /> electric,wall heater in front room <br /> 10/10/2013 10/10/2013 PlbgRoughln SDP Corr Reqd Sec notes 1)Wherc is the vent for the washer box? <br /> Notes:2"waste to the lavatory is not the <br /> toilet vent,OK to vent lavatory using 1 I/2" <br /> pipe <br /> 10/28/2013 10/28/2013 P1bgRoughIn SDP Corr Reqd Re-plumb washer <br /> vent <br /> 10/28/2013 10/28/2013 GasPiping SDP Corr Reqd T'est gas pipe& <br /> install nail plates <br /> 10/30/2013 10/30/2013 P1bgRoughIn SDP Approval <br /> 10/30/2013 10/30/2013 GasPiping SDP Approval See notes Gas tested at 15 PSI-OK for service <br /> 10/30/2013 10/30/2013 MechRoughIn SDP Approval See notes Mechanical Rough In Ok as noted:At final <br /> inspector will look at stove exhaust tluough <br /> the exterior walL <br /> 11/12/2013 11/12/2013 Fra�ning KMK PartialApproval Sce notes 1)Bedroom#2 egress window is at48", <br /> need 44"sill height(see plans) <br /> 2)OK to rock al1 other areas except#1 <br /> 4/15/2014 4/15/2014 Final Plbg SDP Approval OK,fix water leaks <br /> at hot water tank <br /> 4/15/2014 4/I S/2014 Pinal Mech SDP Approval See notes Mechnical final OK as noted: <br /> 1)Install anti-tip on stove <br /> 2)Extend dryer duct out of wall enough to <br /> attach dryer hosc(about 1 U2") <br /> INSY12 <br />