Laserfiche WebLink
• <br />� <br />11. Supports for solar modules are installed to spread the dead load across as many roof- <br />framing members as needed to ensure that no point load exceeds fifty (50) pounds, � ❑ <br />[IRC M2302,2.1(5)] ' <br />12. The photovoltaic modules and supporting structure shall be construcfed of <br />noncombustible materials orfire-retardanttreated wood equivalent to that required for I� ❑ <br />the roof construction. [IRC M2302,2.1] <br />13, Roof and wall penetrations shall be flashed and sealed to prevent entry of water, � <br />rodents, and insects. [IRC M2302.2.2] � <br />14. PV modules are listed and labeled with a fire ciassification in accordance with UL 1703. � � <br />[IRC M2302.2.3] ' <br />Comments: • <br />�=::�'-_�;;�' If you answered yes to ail of the above questions, the project qualifies for fhe over-the- <br />counter permitting process. <br />� Deterrriine if your projec� qualifies for an Over-the-Counter electrical permit <br />Yes No N/A <br />1. PV modules, inverters, and combiner boxes are identified for use in PV systems. � � <br />2. The inverters are listed and labeled in accordance with UL 1741 and are listed for � � <br />utility interaction. [IRC M2302.4) <br />3. The AC interconnection point is on the load side of service disconnect. [NEC 690.64(B)) <br />❑ <br />4. The system meets all current NEC, Gity and Washington Cities Electrical Code � � <br />requirements. <br />5. For 5plit-Buss modules the AC interconnection must be one of the six service � � � <br />disconnects. � <br />6. Maximum load added to the panelboard is based on the rating of the panelboards bus/main OCPD <br />combination in accordance with NEC 705.12(D)(2)(3)(b}, and is limited to (check combination that <br />applies): • <br />❑225 amp bus/200 amp main OCPD - 13,440 AC watts, maximum 70 amp inverter OCPD. <br />❑225 amp bus/225 amp main OCPD - 8,640 AC watts, maximum 45 amp inverter OCPD. <br />❑200 amp bus/200 amp main OCPD - 7,860 AC watts, maximum 40 amp inverter OCPD. <br />�1150 amp bus/150 amp main OCPD - 5,760 AC watts, maximum 30 amp inverter OCPD. <br />❑125 amp bus/125 amp main OCPD - 4,800 AC watts, maximum 25 amp inverter OCPD. <br />❑125 amp bus/100 amp main OCPD - 9,600 AC watts, maximum 50 amp inverter OCPD. <br />