Laserfiche WebLink
� <br />3/:/2015 City of Everett Page 1 <br />Z:2�:a3YNt <br />PermitNo. C1305-004 <br />Applied 5/3/2013 <br />Approved 5/31/2013 <br />Issued 5/31/2013 <br />Parent Pcrmit No. <br />INSPECTION ACTIVITY REPORT <br />Site Address 2107 RUCKER AVE <br />Applicant OWNER Lot <br />Owner HUYNH TUYETLAN Tffi Block <br />Contractor MASTER BUILDERS CONS"C NW LLC Tract <br />Description SPR REMODEL <br />Notes MOVL' KITCHEN, ADll F3A"1'I1IZOOMS, UPllATE PLUM131NG, RENIOVE CHIMNLY <br />Scheduled Comoleted Tvne Insoector Result Remarlcs Insnector's Comments <br />9/(/2013 9/6/2013 PlbgRoughln SDP Corr Rcqd See notcs Vents must be 10' away from ope�ing <br />wittdow <br />9/6/2013 9/6/2013 P16gRoughIn SDP Corr Reqd See notes 1) Waste lines in basement are flat to back <br />graded- hangers are required every4' <br />2) Faucet in upstair tub is not legal- must <br />replace or install an RPBA device <br />3) Vent from washer in attic not complete <br />4) Washer box in closet at back porch? <br />9/17/2013 9/17/2013 PlbgRoughIn SDP Approval See notes Rough-in OK as noted: At final you will <br />need <br />1) The upstairs tub wili require a faucet <br />above the flood rim or an RPBA no <br />exceptions <br />2) Vent in the attic needs to have a studor <br />vent with access and open to air per <br />manufacturers specs <br />3) Washer box for cat box shall have <br />vacuum breakers on the water� no <br />exceptions <br />Questions: call Shellie <br />9/27/2013 9l27/2013 MechRoughIn SDP Corr I2eqd See notes 1) Heat pump must be anchored to pad and <br />ground <br />2) Need the manufac[urers specs for <br />exhaust and intakc terminations <br />3) lluct wurk has niany wt-scalcd joints and <br />openings at seams <br />4) A duct pressure test will berequired <br />5) R-8 insulation is required in basement <br />and attic <br />6) Properly strap flcx duct(do not use <br />electrical conduits) <br />7) Use proper straps on refrigeration pipe <br />8) Exhaust fan in cat room is not <br />complete9) Cover holes in chimney <br />10) Whole house fan must be 1 or less <br />scones <br />9/27/2013 9/27/2013 GasPiping SDP Corr Reqd See notes 1) Not on test <br />2) C.S.S.T flex going upstairs is not <br />properly shieldec� drilled or strapped per <br />manufacturersspecs <br />10/16/2013 10/16/2013 GasPiping SDP Approval See notes Gas rough OK Flex in wall was changed to <br />iron pipe. Pressure tested at 15 PSI - OK. <br />10/16/2013 10/16/2013 MechRoughIn SDP Approval See notes Mech rough OK/ At final I will neecY <br />1) Heat pump ancliored. <br />2) Duct pressure test. <br />3) Refrigeration lines neally insulated and <br />strapped with proper materials <br />4) Add hangers to thc rivo2" PVC <br />(venUcombustion) lines from furnace. <br />INSP12 <br />