Laserfiche WebLink
GENERAL YES NO <br />Bathroom doors are easily and quickly openable from the outside when locked � � <br />Carbon Monoxide alarms are installed as required in R315.1 on each level of the home. � 0 <br />Smoke alarms are installed on all levels of the dwelling, in each resident sleeping room, outside each separate <br />sleeping area in the immediate vicinity of sleeping rooms (R314). � � <br />Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all � � <br />parts of the dwelling upon activation of a single device. <br />Access road and water supply meet local fire jurisdictional requirements. � 0 <br />R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand <br />and shall not require tight grasping, pinching or twisting of the wrist (lever-type). � � <br />Pocket doors shall have graspable hardware available when in the closed or open position. � Q <br />R311.8 Ramps YE$ NO <br />Inside Ramp N/A � Q Q <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not ailowed in AFH) <br />R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes <br />directions. Q Q <br />R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1– R311.8.3.3. Q Q <br />outside Ramp N�q Q YES NO <br />R311.8.1 Maximum Slope one unit vertical in twelve units horizontal (8.3% slope). (Exception R311.8.1 Not allowed in AFH) Q <br />R311.8.2 Landing Requirements: min. 3X3 foot landing at top/bottom, where doors open onto ramps, and where ramp changes � � <br />directions. <br />R325.9.1 Handrails required on both sides of ramp in accordance with R311.8.3.1– R311.8.3.3. � � <br />Guards below are depicted vertically as an example only. All Ramps must have Guards � 0 <br />Guard <br />36" min <br />Handrail both sides <br />Less than 4" � 34" - 38" <br />3'x3'min <br />landing <br />3'x3'min <br />IandinQ <br />---� ------ -- � --- <br />i <br />— 3' One unit vertical in twelve units horizontal � a 3' — <br />minimum is an 83% slope all along surface of the ramp. � minimum <br />R311.2 Means of Egress - YES NO <br />R311.2 Door must be side-hinged with min. width of 32 inches between face of door and stop. Height not less than 78 inches. <br />R325.4 Operable parts of door handles, pulls, latches, locks and other devices installed in AFH shall be operable with one hand <br />and shall not require tight grasping, pinching or twisting of the wrist (lever-type). � 0 <br />R325.4 Required exit door hardware shall unlock inside and outside mechanisms when exiting the building allowing re-entry � Q <br />without use of key, tool or special knowledge. Required exit door shall have no additional locking devices. <br />R311.7 Stairways N/A �, YE$ NO <br />R311.7.4.1 Riser Height: Max riser height shall be 7% inches (8 inches in structures built prior to July 1, 2004) <br />R311.7.4.2 Tread Depth: Min. tread depth shall be in 10 inches (9 inches in structures built prior to July 1, 2004) Q 0 <br />R325.10.1 Handrails for Treads and Risers shall be installed on both sides of treads and risers numbering from one riser to multiple � � <br />risers. Handrails shall be installed in accordance with R311.7.7.1– R311.7.7.4 <br />[�ffective: 2013 July 01 <br />Updated: 2013 June <br />